Meet ApplyKite Twin, the application assistant that learns with you
Meet your Twin, it learns with you
Your Twin learns with you
Launch week codes:30% off annual Pro20% off monthly Pro
Ends in00h00m00s
Ends in00h00m00s
Abdelsalam Elhaffar
Associate professor
Research Interests
Make your next move.
Prepare your application
Review drafts before you send them.
Explore related searches
Articles (8)
Year:
2026
Year:
2025
This study aimed to optimize the incorporation of static var compensators (SVCs) into Oman’s main interconnected system (MIS) using real 2023 MIS data. Leveraging the particle swarm optimization (PSO) algorithm within MATLAB, substantial enhancements were achieved in voltage profiles, with associated losses reducing by roughly 2%. A multi-objective strategy effectively managed costs while preserving improved voltage profiles and controlled losses. Validation through DigSILENT showcased the dynamic advantages of optimal SVC placement through consistently elevating voltage profiles and mitigating losses, notably within the Muscat region. Analyses encompassing harmonics, transient stability, and load distribution indicated that harmonics remained within acceptable thresholds, and overall system stability was enhanced. Optimal SVC deployment expedited the attainment of steady-state conditions, as illustrated via the QV curve, demonstrating increased stability as the buses loaded from 18% to 96%. These findings underscore the robust and efficient nature of SVC integration as a viable solution within Oman’s MIS system, addressing voltage profile enhancement, loss minimization, and fortified system stability.
Year:
2023
Adaptive protection schemes have been developed to address the problem of behavior-changing power systems integrated with inverter-based generation (IBG). This paper proposes a machine-learning-based fault detection and classification technique using a setting-group-based adaptation approach. Multigroup settings were designed depending on the types of power generation (synchronous generator, PV plant, and type-3 wind farm) connected to a transmission line in the 39-Bus New England System. For each system topology, an optimized pretrained ensemble tree classifier was used. The adaptation process has two phases: an offline learning phase to tune the classifiers and select the optimum subset of features, and an online phase where the circuit breaker (CB) status and the active output power of the generators are continuously monitored to identify the current system topology and to select the appropriate setting group. The proposed system achieved an average accuracy of 99.4%, a 99.5% average precision, a 99.9% average specificity, and a 99.4% average sensitivity of classification. The robustness analysis was conducted by applying several fault scenarios not considered during training, which include different transmission network configurations and different penetration levels of IBGs. The case of incorrect selection of the appropriate setting group resulting from selecting the wrong topology is also considered. It was noticed that the performance of developed classifiers deteriorates when the transmission network is reconfigured and the incorrect setting group is selected.
Year:
2023
Year:
2022
Year:
2022
Year:
2021
Year:
2021
Collaborators (4)
Ahmet Onen
University of Doha for Science & Technology
Majdi Mansouri
Associate Professor
Sultan Qaboos University
Abdullah AlBadi
Professor
Sultan Qaboos University
Mostefa Mesbah
-
Make your next move.
Prepare your application
Review drafts before you send them.