Ahmet Örgev
Clinical Associate Professor
Research Interests
Explore related searches
Contact this professor
Get a free first email built on one of their papers, ready for you to edit and send yourself.
About
Ahmet Örgev is a Clinical Associate Professor at the University at Buffalo, State University of New York. His research areas focus on additively manufactured dental materials, including the dimensional stability of bio-based resins and their applications in dental prosthetics. He has published extensively on topics such as the fracture strength of implant-supported prostheses and the effects of various materials on dental casting properties. Dr. Örgev's work contributes to advancements in restorative dentistry and the integration of artificial intelligence in clinical practices.
Articles (14)
Year:
2025
Year:
2025
Year:
2025
Year:
2025
Year:
2025
Year:
2024
Year:
2024
Year:
2024
Year:
2024
Purpose This in vitro study aimed to compare flexural strength, surface roughness, and biofilm formation of ceramic‐reinforced polyetheretherketone (PEEK) with conventionally heat‐compressed and milled polymethylmethacrylate (PMMA) denture base materials. Materials and Methods Thirty strips (6.4 mm × 10 mm × 3 mm) and 30 discs (10 mm × 1 mm) were fabricated from a heat‐compressed PMMA, milled PMMA, and ceramic‐reinforced PEEK, 10 each. One surface of each sample was polished to mimic the laboratory procedure for denture base materials. Strips were then subjected to a three‐point bend test using a universal testing machine at a crosshead speed of 5.0 mm/min. An optical profilometer was used to assess the Ra value (mm) of the discs on polished and unpolished sides. Biofilm formation behavior was analyzed by measuring the colony‐forming unit (CFU)/mL of Candida albicans on the unpolished surface of the discs. One‐way ANOVA followed by Tukey multiple comparison tests were used to compare the flexural strength, Ra value, and biofilm formation of the studied materials ( a = 0.05). Results Ceramic‐reinforced PEEK showed significantly higher flexural strength (178.2 ± 3.2 MPa) than milled PMMA (89.6 ± 0.8 MPa; p < 0.001) and heat‐compressed PMMA (67.3 ± 5.3 MPa; p < 0.001). Ceramic‐reinforced PEEK exhibited a significantly higher Ra value than the other groups on unpolished sides; however, the polishing process significantly reduced the Ra values of all studied groups ( p < 0.05). There was no significant difference in C. albicans adhesion among the groups ( p < 0.05). Conclusion The flexural strength of tested materials was within acceptable limits for clinical use as a denture base material. Ceramic‐reinforced PEEK had the highest surface roughness; however, its similarity in biofilm formation to other groups indicates its clinical acceptability as denture base material.
Year:
2023
Year:
2022
Year:
2022
Year:
2022
Year:
2021
Collaborators (6)
Vinicius Rizzo Marques
Assistant professor
University at Albany, State University of New York
Rui Li
-
Luiz Gonzaga
Associate Professor Center for Implant Densitry
University of Florida
Ramtin Sadid‐Zadeh
-
Chin Chun Peng
Assistant teaching professor
University of Washington
Tien-Min Gabriel Chu
Professor
Indiana University School of Dentistry
Make your next move.
Prepare your application
Review drafts before you send them.