Andrew Tirsi

MD, Scientist, Assistant Professor

Mie Daigaku
Country flagUnited States

Research Interests

ApplyKite TwinLearns as you apply

Make your next move.

Prepare your application

Review drafts before you send them.

Explore related searches

About

Dr. Andrew Tirsi is an Assistant Professor at MEETH in the United States. His research focuses on glaucoma, specifically the use of pattern electroretinography and retinal imaging to diagnose and analyze retinal ganglion cell health. His recent publications delve into various aspects of glaucoma diagnostics and treatment outcomes, including the efficacy of micropulse laser trabeculoplasty and the correlations of retinal function with structural metrics.

Articles (11)

Background/Objectives: The early detection of retinal ganglion cell (RGC) dysfunction is critical for timely intervention in glaucoma suspects (GSs). The combined structure–function index (CSFI), which uses visual field and optical coherence tomography (OCT) data to estimate RGC counts, may be of limited utility in GSs. This study evaluates whether steady-state pattern electroretinogram (ssPERG)-derived estimates better predict early structural changes in GSs. Methods: Fifty eyes from 25 glaucoma suspects underwent ssPERG and spectral-domain OCT. Estimated RGC counts (eRGCC) were calculated using three parameters: ssPERG-Magnitude (eRGCCMag), ssPERG-MagnitudeD (eRGCCMagD), and CSFI (eRGCCCSFI). Linear regression and multivariable models were used to assess each model’s ability to predict the average retinal nerve fiber layer thickness (AvRNFLT), average ganglion cell layer–inner plexiform layer thickness (AvGCL-IPLT), and rim area. Results: eRGCCMag and eRGCCMagD were significantly correlated with eRGCCCSFI. Both PERG-derived models outperformed eRGCCCSFI in predicting AvRNFLT and AvGCL-IPLT, with eRGCCMagD showing the strongest association with AvGCL-IPLT. Conversely, the rim area was best predicted by eRGCCMag and eRGCCCSFI. These findings support a linear relationship between ssPERG parameters and early RGC structural changes, while the logarithmic nature of visual field loss may limit eRGCCCSFI’s predictive accuracy in GSs. Conclusions: ssPERG-derived estimates, particularly eRGCCMagD, better predict early structural changes in GSs than eRGCCCSFI. eRGCCMagD’s superior performance in predicting GCL-IPLT highlights its potential utility as an early biomarker of glaucomatous damage. ssPERG-based models offer a simpler and more sensitive tool for early glaucoma risk stratification, and may provide a clinical benchmark for tracking recoverable RGC dysfunction and treatment response.

Year:

2025

Year:

2025

Year:

2025

Background/Objectives: The aim of this study was to evaluate the relationship between foveal avascular zone (FAZ) enlargement, retinal ganglion cell (RGC) dysfunction, and structural retinal measurements in glaucoma suspects (GS), using pattern electroretinogram (PERG) and optical coherence tomography angiography (OCTA) parameters. Methods: Thirty-one eyes (20 subjects) of GS status underwent comprehensive ophthalmologic evaluation including steady-state PERG, optical coherence tomography (OCT), and OCTA. FAZ area was measured using ImageJ software (version 1.54p), and PERG parameters (Magnitude, MagnitudeD, and MagnitudeD/Magnitude ratio) were analyzed. Partial correlation analyses were performed to assess associations between FAZ area, PERG parameters, and structural metrics including retinal nerve fiber layer (RNFL), ganglion cell layer–inner plexiform layer (GCL + IPL), and macular thickness. Results: After controlling for age, sex, central corneal thickness (CCT), intraocular pressure (IOP), and spherical equivalent, partial correlation analysis showed that FAZ area was significantly associated with both lower Magnitude (r < −0.503, p < 0.05) and MagnitudeD (r < −0.507, p < 0.05) values. PERG parameters were significantly correlated with superior and average RNFL thickness, as well as superior and superior temporal GCL + IPL thickness. FAZ area was significantly associated with multiple GCL + IPL and macular thickness sectors, but not with RNFL thickness. Conclusions: FAZ enlargement is significantly associated with RGC dysfunction and inner retinal layer thinning in GS.

Year:

2025

Background/Objectives: The aim of this study was to evaluate the associations between optical coherence tomography angiography (OCTA)-based retinal vessel diameter (RVD) measurements, with retinal ganglion cell (RGC) function assessed by means of steady-state pattern electroretinography (ssPERG) using ganglion cell layer-inner plexiform layer thickness (GCL-IPLT) measurements and with Humphrey field analyzer (HFA) global indices in glaucoma suspects (GSs). Methods: Thirty-one eyes (20 participants) underwent a comprehensive ophthalmologic examination, ssPERG measurements utilizing the PERGLA paradigm, HFA, optical coherence tomography (OCT), and OCTA. The OCTA scans were processed using ImageJ software, Version 1.53, allowing for measurement of the RVD. Multiple linear regression models were used. Results: After controlling for age, race, central corneal thickness (CCT), and spherical equivalent (SE), a linear regression analysis found that the RVD explained the 4.7% variance in magnitude (Mag) (p = 0.169), 9.2% variance in magnitudeD (MagD) (p = 0.021), and 16.9% variance in magnitudeD/magnitude (p = 0.009). After controlling for age, CCT, and signal strength (SS), a linear regression analysis found that the RVD was significantly associated with the GCL-IPLT measurements (average GCL-IPL, minimum GCL-IPL, superior, superonasal, inferior, and inferonasal sectors) (p ≤ 0.023). An identical regression analysis where the RVD was replaced with the PERG parameters showed a significant association between the MagD and almost all GCI-IPLT measurements. RVD measurements were significantly associated with HFA VFI 24-2 (p = 0.004), MD 24-2 (p < 0.001), and PSD 24-2 (p = 0.009). Conclusions: Decreased RVD measurements were significantly associated with RGC dysfunction, decreased GCL-IPLT, and all HFA global indices in the GSs.

Year:

2025

Year:

2024

Purpose. The purpose of this study was to investigate the utility of steady state pattern electroretinogram (ss-PERG) in detecting retinal ganglion cell (RGC) dysfunction in glaucoma suspects (GS) who had normal 24-2 Humphrey Visual Fields (HFA). Materials and Methods. This was a prospective cohort study of GS patients who were identified based on optic disc appearance with normal HFAs. Patients received a complete eye examination, standard automated perimetry (SAP), optical coherence tomography (OCT), and ss-PERG measurements. The ss-PERG parameters, Magnitude (Mag), Magnitude D (MagD), and MagD/Mag ratio, were examined, along with their relationships between HFA and OCT measurements. Results. Twenty-five patients were included in this study, with a total of 49 eyes. Fifteen eyes had abnormal ss-PERG parameters and when compared to GS eyes with normal ss-PERG parameters, there were significant differences in HFA 24-2, retinal nerve fiber layer (RNFL) thickness, and ganglion cell layer and inner plexiform layer (GCL + IPL) thickness. All ss-PERG parameters were significantly correlated with 24-2 VF mean deviation (MD) and visual field index (VFI), as well as 10-2 VF MD after controlling for age, sex, intraocular pressure, central corneal thickness, and spherical equivalent. When controlled for age, spherical equivalent, and IOP, MagD/Mag ratio significantly contributed to the variance in average GCL + IPL thicknesses, whereas 24-2 VF MD and 10-2 VF MD did not. MagD/Mag ratio also significantly accounted for variance in all macular GCL + IPL sectors, while 10-2 VF MD did not. Conclusions. ss-PERG has significant correlations with HFA global indices and was predictive of GCL + IPL thickness in GS patients. Clinical Significance. ss-PERG may serve as a useful functional tool for detecting and measuring RGC dysfunction in GS. It appears to be more sensitive than HFA in the detection of early changes in GCL + IPL thicknesses and may be helpful to use in conjunction with current diagnostic studies to improve the ability of monitoring GS progression.

Year:

2024

Year:

2023

Year:

2022

Year:

2022

Year:

2021