Ante Hecimovic
Senior scientist
Research Interests
Make your next move.
Prepare your application
Review drafts before you send them.
Explore related searches
Articles (6)
Year:
2026
Year:
2026
Year:
2025
A diagnostic setup for one-dimensionally spatially resolved two-photon absorption laser-induced fluorescence (TALIF) detection of ground state oxygen atoms ( 2 p 4 3 P 2 , 1 , 0 ) is developed. The goal of this study is to investigate the evolution of temperatures and absolute number densities of oxygen atoms along the effluent of a low-pressure CO 2 microwave discharge in order to gain insights into some of the mechanisms governing the post-discharge regime. The plasma source is operated at conditions of 600 W– 1200 W of absorbed power with flow rates of 74 sccm and 370 sccm pure CO 2 at pressures between 1.2 mbar and 5 mbar with specific energy inputs up to 111.9 eV/molecule. These operating conditions exhibit high CO 2 conversions (up to 90%) at low energy efficiencies (2%–7.4%), due to direct electron impact dissociation driving the conversion process resulting in splitting of CO 2 into CO and metastable oxygen atoms. The TALIF measurements yield spatially resolved translational temperatures between 1000 K– 1600 K for most operating conditions and axial positions along the effluent. Reference measurements with xenon 6 p ′ [ 3 / 2 ] 2 are used for absolute number density calibration. The resulting axially resolved number density profiles of ground state atomic oxygen increase along the effluent, even at considerable distances of several centimeters from the active discharge, before they reach a maximum between 5 × 10 20 m −3 and 2.2 × 10 21 m −3 depending on the condition, and decrease after that. This behavior indicates the potential significance of quenching of metastable oxygen atoms within the post-discharge regime of the investigated CO 2 discharges. The measured spatially resolved number density evolutions are qualitatively consistent with quenching via wall collisions being the dominant deactivation mechanism, underlining the importance of particle-wall interactions.
Year:
2024
Year:
2024
The CO 2 → CO + 1 2 O 2 conversion experiment [D’Isa et al 2020 Plasma Sources Sci. Technol. 29 105009] has been compared with thermo-chemical calculations. The experiment is a 2.45 GHz plasma torch with a straight channel in the effluent. The 1.5D model of the CO 2 /CO/O 2 /O/C mixture without turbulent transport has been applied with plasma acting only as a prescribed heat source. The parameter range covered is the specific energy input (SEI) 0.3–5 eV/molecule at pressure p = 0.9 bar, and SEI = 0.6–2 eV/molecule at p = 0.5, 0.2 bar. The calculated conversion χ is always close to the experimental values. At the same time, the calculated temperatures T deviate significantly from the experiment, especially for p = 0.2 bar. The calculated T were also found to be sensitive with respect to the uncertain model parameters, but χ is not sensitive. The net conversion in the model is driven to a large extent by the radial diffusion of CO and O from the hot core towards the wall and steep radial temperature gradients. The main factor that reduces the energy efficiency is the re-oxidation of CO at the edge of the hot plasma region and downstream. The 1.5D approximation applied has the principle limitation that the impact of a realistic bulk flow field on the chemical process cannot be studied. Hence, the results must be considered preliminary and have to be confirmed with a more elaborate and accurate model of the vortex-stabilized flow inside the reactor.
Year:
2024
Collaborators (1)
Arne Meindl
Max Planck Institute for Plasma Physics
Make your next move.
Prepare your application
Review drafts before you send them.