Apostolos Tzikas

Aristotle University of Thessaloniki
Country flagGreece

Research Interests

Contact this professor

Get a free first email built on one of their papers, ready for you to edit and send yourself.

Articles (9)

Year:

2025

Year:

2025

Year:

2024

Year:

2024

Year:

2024

Background and Aims Residual leaks are not infrequent after left atrial appendage occlusion. However, there is still uncertainty regarding their prognostic implications. The aim of this study is to evaluate the impact of residual leaks after left atrial appendage occlusion. Methods A literature search was conducted until 19 February 2023. Residual leaks comprised peri-device leaks (PDLs) on transoesophageal echocardiography (TEE) or computed tomography (CT), as well as left atrial appendage patency on CT. Random-effects meta-analyses were performed to assess the clinical impact of residual leaks. Results Overall 48 eligible studies (44 non-randomized/observational and 4 randomized studies) including 61 666 patients with atrial fibrillation who underwent left atrial appendage occlusion were analysed. Peri-device leak by TEE was present in 26.1% of patients. Computed tomography-based left atrial appendage patency and PDL were present in 54.9% and 57.3% of patients, respectively. Transoesophageal echocardiography-based PDL (i.e. any reported PDL regardless of its size) was significantly associated with a higher risk of thromboembolism [pooled odds ratio (pOR) 2.04, 95% confidence interval (CI): 1.52–2.74], all-cause mortality (pOR 1.16, 95% CI: 1.08–1.24), and major bleeding (pOR 1.12, 95% CI: 1.03–1.22), compared with no reported PDL. A positive graded association between PDL size and risk of thromboembolism was noted across TEE cut-offs. For any PDL of >0, >1, >3, and >5 mm, the pORs for thromboembolism were 1.82 (95% CI: 1.35–2.47), 2.13 (95% CI: 1.04–4.35), 4.14 (95% CI: 2.07–8.27), and 4.44 (95% CI: 2.09–9.43), respectively, compared with either no PDL or PDL smaller than each cut-off. Neither left atrial appendage patency, nor PDL by CT was associated with thromboembolism (pOR 1.45 and 1.04, 95% CI: 0.84–2.50 and 0.52–2.07, respectively). Conclusions Peri-device leak detected by TEE was associated with adverse events, primarily thromboembolism. Residual leaks detected by CT were more frequent but lacked prognostic significance.

Year:

2023

Year:

2023

Year:

2021

Year:

2021

Collaborators (2)

Ole De Backer

-

DENMARK
View details

Marek Grygier

Director of Catherization Laboratory and Head of Structural Heart Interventions Program

Poznan University of Medical Sciences

POLAND
View details
ApplyKite TwinLearns as you apply

Make your next move.

Prepare your application

Review drafts before you send them.