Aritrick Chatterjee
Has grant
Research Assistant Professor
Research Interests
Explore related searches
Contact this professor
Get a free first email built on one of their papers, ready for you to edit and send yourself.
Recent Grants
Grant: Close
AI-Driven Tutorials for Radiology Student Training
Open Date: 2021-03-01
Close Date: 2023-02-01
Grant: Close
Automated Prostate Cancer Detection using Hybrid Multi-dimensional MRI and Deep Learning
Open Date: 2020-05-01
Close Date: 2021-05-01
Grant: Close
MR based quantitative analysis and tissue composition measures in high risk population for prostate cancer: Racial discrepancies and impact on cancer detection
Open Date: 2019-07-01
Close Date: 2020-06-01
Grant: Close
Detection of prostate Cancer Specific Signals with Hybrid Multi-Dimensional MRI
Open Date: 2019-04-01
Close Date: 2024-03-01
Grant: Close
MR Virtual Pathology of the Prostate
Open Date: 2019-04-01
Close Date: 2021-03-01
Articles (13)
Purpose This study addresses the challenge of low resolution and signal‐to‐noise ratio (SNR) in diffusion‐weighted images (DWI), which are pivotal for cancer detection. Traditional methods increase SNR at high b ‐values through multiple acquisitions, but this results in diminished image resolution due to motion‐induced variations. Our research aims to enhance spatial resolution by exploiting the global structure within multicontrast DWI scans and millimetric motion between acquisitions. Methods We introduce a novel approach employing a “Perturbation Network” to learn subvoxel‐size motions between scans, trained jointly with an implicit neural representation (INR) network. INR encodes the DWI as a continuous volumetric function, treating voxel intensities of low‐resolution acquisitions as discrete samples. By evaluating this function with a finer grid, our model predicts higher‐resolution signal intensities for intermediate voxel locations. The Perturbation Network's motion‐correction efficacy was validated through experiments on biological phantoms and in vivo prostate scans. Results Quantitative analyses revealed significantly higher structural similarity measures of super‐resolution images to ground truth high‐resolution images compared to high‐order interpolation ( p 0.005). In blind qualitative experiments, of super‐resolution images were assessed to have superior diagnostic quality compared to interpolated images. Conclusion High‐resolution details in DWI can be obtained without the need for high‐resolution training data. One notable advantage of the proposed method is that it does not require a super‐resolution training set. This is important in clinical practice because the proposed method can easily be adapted to images with different scanner settings or body parts, whereas the supervised methods do not offer such an option.
Year:
2024
Year:
2024
Year:
2023
Year:
2022
Year:
2022
Year:
2022
Year:
2022
Year:
2022
Year:
2022
Year:
2022
Year:
2021
Year:
2021
Year:
2020
Collaborators (6)
Milica Medved
Research Associate Professor
University of Chicago
Roger Bourne
University of Sydney
Gregory S. Karczmar
-
Batuhan Gundogdu
University of Chicago
Carla Harmath
Associate Professor
University of Chicago
Tatjana Antic
University of Chicago
Make your next move.
Prepare your application
Review drafts before you send them.