Aritza Brizuela-Velasco
Research Interests
Explore related searches
Contact this professor
Get a free first email built on one of their papers, ready for you to edit and send yourself.
Articles (11)
This study aims to analyse, using a finite element analysis, the effects of Ti-base abutment height on the distribution and magnitude of transferred load and the resulting bone microstrain in the bone-implant system. A three-dimensional bone model of the mandibular premolar section was created with an implant placed in a juxta-osseous position. Three prosthetic models were designed: a 1 mm-high titanium-base (Ti-base) abutment with an 8 mm-high cemented monolithic zirconia crown was designed for model A, a 2 mm-high Ti-base abutment with a 7 mm-high crown for model B, and a 3 mm-high abutment with a 6 mm-high crown for model C. A static load of 150 N was applied to the central fossa at a six-degree angle with respect to the axial axis of the implant to evaluate the magnitude and distribution of load transfer and microstrain. The results showed a trend towards a direct linear association between the increase in the height of the Ti-base abutments and the increase in the transferred stress and the resulting microstrain to both the prosthetic elements and the bone/implant system. An increase in transferred stress and deformation of all elements of the system, within physiological ranges, was observed as the size of the Ti-base abutment increased.
Year:
2024
In the placement of dental implants, the primary fixation between the dental implant and the bone is of great importance and corresponds to compressive mechanical fixation that aims to prevent micromovement of the implant. The aim of this research was to determine the role of roughness and the type of dental implant (tissue-level or bone-level) in implant stability, measured using resonance frequency analysis (RFA) and insertion torque (IT). We analyzed 234 titanium dental implants, placed in fresh calf ribs, at the half-tissue level and half-bone level. The implant surface was subjected to grit-blasting treatments with alumina particles of 120, 300, and 600 μm at a projection pressure of 2.5 bar, resulting in three types of roughness. Roughness was determined via optical interferometry. The wettability of the surfaces was also determined. Implant stability was measured using a high-precision torquemeter to obtain IT, and RFA was used to determine the implant stability quotient (ISQ). The results show that rough surfaces with Sa values of 0.5 to 4 μm do not affect the primary stability. However, the type of implant is important; bone-level implants obtained the highest primary stability values. A good correlation between the primary stability values obtained via IT and ISQ was demonstrated. New in vivo studies are necessary to know whether these results can be maintained in the long term.
Year:
2023
Year:
2022
Year:
2022
Year:
2022
Year:
2022
Year:
2022
Year:
2022
Year:
2022
Year:
2021
Year:
2021
Collaborators (7)
Blanca Gil Marqués
Associate Professor: Oral Surgery
Universidad Católica de Valencia San Vicente Mártir Facultad de Medicina Facultad de Medicina y Odontología
Javier Gil
-
Maria Dolores Gómez Adrián
Profesora titular
Universidad Católica de Valencia San Vicente Mártir Facultad de Medicina Facultad de Medicina y Odontología
Antonio Pallarés-Sabater
Profesor agregado
Universidad Católica de Valencia San Vicente Mártir
Fernando Sánchez Lasheras
University of Oviedo
Miquel Punset fuste
Head of Engineering services of BBT Research group
Universitat Politècnica de Catalunya
BLANCA RÍOS-CARRASCO
Profesora sustituta interina
Universidad de Sevilla
Make your next move.
Prepare your application
Review drafts before you send them.