Barbara Sándor
Senior lecturer
Research Interests
Explore related searches
Contact this professor
Get a free first email built on one of their papers, ready for you to edit and send yourself.
About
Barbara Sándor is a Senior Lecturer at the University of Pecs in Hungary. Her research areas include cardiopulmonary characteristics related to post-COVID syndrome, microcirculation, and cardiovascular health, with a particular focus on diabetic patients and adolescents. She has published several articles examining the effects of triglyceride levels on microcirculation and the relationship between obesity and physical performance. Additionally, her work addresses the screening for peripheral artery disease and the implications of self-esteem and body image on adolescents' health.
Articles (9)
Year:
2025
Year:
2024
Toe–brachial index (TBI) measurement helps to detect peripheral artery disease (PAD) in patients with incompressible ankle arteries due to medial arterial calcification, which is most frequently associated with diabetes. We aimed to evaluate how an automated four-limb blood pressure monitor equipped with TBI measurement could contribute to PAD screening. In 117 patients (mean age 63.2 ± 12.8 years), ankle–brachial index (ABI) measurement was performed using the Doppler-method and the MESI mTablet. TBI was obtained via photoplethysmography (MESI mTablet, SysToe) and a laser Doppler fluxmeter (PeriFlux 5000). Lower limb PAD lesions were evaluated based on vascular imaging. A significant correlation was found between Doppler and MESI ankle–brachial index values (r = 0.672), which was stronger in non-diabetic (r = 0.744) than in diabetic (r = 0.562) patients. At an ABI cut-off of 0.9, Doppler (AUC = 0.888) showed a sensitivity/specificity of 67.1%/97.4%, MESI (AUC 0.891) exhibited a sensitivity/specificity of 57.0%/100%; at a cut-off of 1.0, MESI demonstrated a sensitivity/specificity of 74.7%/94.8%. The TBI values measured using the three devices did not differ significantly (p = 0.33). At a TBI cut-off of 0.7, MESI (AUC = 0.909) revealed a sensitivity/specificity of 92.1%/67.5%. Combining MESI ABI and TBI measurements recognised 92.4% of PAD limbs. Using an ABI cut-off level of 1.0 and sequential TBI measurement increases the sensitivity of the device in detecting PAD. The precise interpretation of the obtained results requires some expertise.
Year:
2023
Year:
2023
Year:
2021
Year:
2021
Year:
2020
Year:
2020
Year:
2020
Collaborators (5)
Tamas Habon
University of Pecs
Dóra Endrei
University of Pecs
Laszlo Szereday
associate professor
University of Pecs
Robert Halmosi
associate professor
University of Pecs
Gábor Késmárky
-
Make your next move.
Prepare your application
Review drafts before you send them.