Bart Meuris
Research Interests
Explore related searches
Contact this professor
Get a free first email built on one of their papers, ready for you to edit and send yourself.
Articles (8)
OBJECTIVES We present the long-term results of a trileaflet (Triflo) versus bileaflet (On-X) mechanical valve in both aortic and pulmonary positions in a sheep model. METHODS The Triflo valve was implanted in 21 female sheep in aortic (n = 8) and pulmonary position (n = 13). The On-X valve was implanted in 7 female sheep in aortic (n = 1) and pulmonary (n = 6) positions. No antithrombotic medication of any kind was given postoperatively. In the aortic group, survival cohorts were 3 and 5 months. In the pulmonary group, survival cohorts were 10 and 20 weeks. Valve performance was assessed using haematology, echocardiography and acoustic measurements combined with post-mortem pathology analysis of the downstream organs. RESULTS The mean gradients were lower for the Triflo valve in both pulmonary [4.30 mmHg (3.70–5.73) vs 6.80 mmHg (4.63–7.96), P = 0.012] and aortic [5.1 mmHg (4.2–7.7) vs 10.7 mmHg (8.7–12.9), P = 0.007] positions. Peak gradients were lower for the Triflo valve in both pulmonary [8.05 mmHg (6.75–10.23) vs 13.15 mmHg (9.20–14.76), P = 0.005] and aortic [8.7 mmHg (7.5–12.5) vs 16.5 mmHg (14.2–19.6), P = 0.009] positions. In both positions, leaflets and housing surface were free from any deposits macro- and microscopically and comparable to nonimplanted control valves. Peripheral organs showed no signs of thrombo-embolic damage. Biochemical and haematological were comparable to preoperative. The closing click sound pressure level of the Triflo was significantly lower in both aortic [108.4 sound pressure level (102.0–115.7) vs 111.7 sound pressure level (105.5–117.0), P < 0.001] and pulmonary [103.6 sound pressure level (99.1–108.9) vs 118.5 sound pressure level (116.7–120.2), P < 0.001] position. CONCLUSIONS Preliminary in vivo results of the Triflo valve are promising in both aortic and pulmonary positions in an ovine model. Excellent haemodynamics, stable long-term function, low valve noise and no thrombo-embolic events in the absence of antithrombotic medication lay the foundation to a future clinical first-in-man trial.
Year:
2023
Year:
2023
Year:
2023
Year:
2022
Year:
2022
Year:
2022
Year:
2021
Year:
2021
Collaborators (5)
thierry Folliguet
Chairman/Professor
Université Paris-Est Créteil Val de Marne
Steffen Rex
University Hospitals Leuven
Paul Herijgers
Full professor
KU Leuven
Peter Verbrugghe
University Hospitals Leuven
Tom Treasure
University College London
Make your next move.
Prepare your application
Review drafts before you send them.