Caroline Gorin
Has grant
Research Interests
Explore related searches
Contact this professor
Get a free first email built on one of their papers, ready for you to edit and send yourself.
Recent Grants
Grant: Open
3DBioMax
Open Date: 2023-02-01
Close Date: 2027-02-01
Grant: Close
3D-PEEK-Max
Open Date: 2021-12-01
Close Date: 2023-12-01
Grant: Close
Tissue Engineering in Craniofacial Bone Regeneration: Angiogenic and Osteogenic features of dental pulp stem cells
Open Date: 2020-11-01
Close Date: 2023-10-01
Articles (5)
Purpose To evaluate and compare the initial retention force of three resilient unsplinted attachment systems for implant‐retained mandibular overdentures: two cylindrical attachment systems (Locator R‐Tx® and Novaloc®), and one ball attachment system (Ball System). Materials and Methods For each attachment system, initial retention is measured as the average of the maximal dislodging forces during 10 insertion‐removal cycles. For the Ball System, three activation degrees of the matrix are included versus four and six color‐coded retention devices for the Locator R‐Tx® and the Novaloc®, respectively, to represent the complete regular retention devices panel. For each retention device or activation degree, eight samples are tested. Results The initial retention range is similar between the Ball System (7.7 ± 3.4 N – 19.9 ± 4.6 N) and the Novaloc® (2.0 ± 0.5 N – 18.9 ± 1.4 N) and broader for the Locator R‐Tx® (3.3 ± 5.0 N – 60.2 ± 6.0 N). In each attachment system, the initial retention of each retention device is significantly different from the others, except for the two most retentive Novaloc® ones. Retention devices were also classified according to their initial retention (low, medium, and maximum). In each retention group, the Novaloc® and the Ball System provided similar retention values lower than the Locator R‐Tx®. Conclusion Most of the retention devices tested provided an initial retention force of over 5 N for all three attachment systems. The Locator R‐Tx® had the most comprehensive range, and the Novaloc® seemed to provide the most reproducible values, unlike the Ball System due to the activation required by the operator.
Year:
2023
Year:
2022
Year:
2022
Year:
2021
Year:
2021
Collaborators (5)
Halima KERDJOUDJ
Professor
Université de Reims Champagne-Ardenne
Jeremy Sadoine
Université Paris Descartes
Aurélie Benoit
innovative biomaterials and interfaces research unit – ur4462 university paris cité montrouge france
Rümeyza Bascetin
Université de Lorraine
Adrien Baldit
Associate professor
Université de Lorraine
Make your next move.
Prepare your application
Review drafts before you send them.