Caroline Gorin

Has grant

Country flagFrance

Research Interests

Explore related searches

Contact this professor

Get a free first email built on one of their papers, ready for you to edit and send yourself.

Recent Grants

Grant: Open

3DBioMax

Open Date: 2023-02-01

Close Date: 2027-02-01

Grant: Close

3D-PEEK-Max

Open Date: 2021-12-01

Close Date: 2023-12-01

Grant: Close

Tissue Engineering in Craniofacial Bone Regeneration: Angiogenic and Osteogenic features of dental pulp stem cells

Open Date: 2020-11-01

Close Date: 2023-10-01

Articles (5)

Purpose To evaluate and compare the initial retention force of three resilient unsplinted attachment systems for implant‐retained mandibular overdentures: two cylindrical attachment systems (Locator R‐Tx® and Novaloc®), and one ball attachment system (Ball System). Materials and Methods For each attachment system, initial retention is measured as the average of the maximal dislodging forces during 10 insertion‐removal cycles. For the Ball System, three activation degrees of the matrix are included versus four and six color‐coded retention devices for the Locator R‐Tx® and the Novaloc®, respectively, to represent the complete regular retention devices panel. For each retention device or activation degree, eight samples are tested. Results The initial retention range is similar between the Ball System (7.7 ± 3.4 N – 19.9 ± 4.6 N) and the Novaloc® (2.0 ± 0.5 N – 18.9 ± 1.4 N) and broader for the Locator R‐Tx® (3.3 ± 5.0 N – 60.2 ± 6.0 N). In each attachment system, the initial retention of each retention device is significantly different from the others, except for the two most retentive Novaloc® ones. Retention devices were also classified according to their initial retention (low, medium, and maximum). In each retention group, the Novaloc® and the Ball System provided similar retention values lower than the Locator R‐Tx®. Conclusion Most of the retention devices tested provided an initial retention force of over 5 N for all three attachment systems. The Locator R‐Tx® had the most comprehensive range, and the Novaloc® seemed to provide the most reproducible values, unlike the Ball System due to the activation required by the operator.

Year:

2023

Year:

2022

Year:

2022

Year:

2021

Year:

2021

Collaborators (5)

Halima KERDJOUDJ

Professor

Université de Reims Champagne-Ardenne

FRANCE
View details

Jeremy Sadoine

Université Paris Descartes

FRANCE
View details

Aurélie Benoit

innovative biomaterials and interfaces research unit – ur4462 university paris cité montrouge france

FRANCE
View details

Rümeyza Bascetin

Université de Lorraine

FRANCE
View details

Adrien Baldit

Associate professor

Université de Lorraine

FRANCE
View details
ApplyKite TwinLearns as you apply

Make your next move.

Prepare your application

Review drafts before you send them.