Your Twin learns with you

30% off annual Pro20% off monthly Pro

Ends in00h00m00s

Dario Faj

Country flagCroatia

Research Interests

ApplyKite TwinLearns as you apply

Make your next move.

Prepare your application

Review drafts before you send them.

Explore related searches

Articles (19)

Year:

2026

Year:

2026

Year:

2026

Year:

2026

Year:

2026

Year:

2025

Year:

2025

Year:

2025

Background Monte Carlo (MC) simulations or measurements in anthropomorphic phantoms are recommended for estimating fetal dose in pregnant patients in radiotherapy. Among the many existing phantoms, there is no commercially available physical phantom representing the entire pregnant woman. Purpose In this study, the development of a low‐cost, physical pregnant female phantom was demonstrated using commercially available materials. This phantom is based on the previously published computational phantom. Methods Three tissue substitution materials (soft tissue, lung and bone tissue substitution) were developed. To verify Tena's substitution tissue materials, their radiation properties were assessed and compared to ICRP and ICRU materials using MC simulations in MV radiotherapy beams. Validation of the physical phantom was performed by comparing fetal doses obtained by measurements in the phantom with fetal doses obtained by MC simulations in computational phantom, during an MV photon breast radiotherapy treatment. Results Materials used for building Tena phantom are matched to ICRU materials using physical density, radiation absorption properties and effective atomic number. MC simulations showed that percentage depth doses of Tena and ICRU material comply within 5% for soft and lung tissue, up to 25 cm depth. In the bone tissue, the discrepancy is higher, but again within 5% up to the depth of 5 cm. When the phantom was used for fetal dose measurements in MV photon breast radiotherapy, measured fetal doses complied with fetal doses calculated using MC simulation within 15%. Conclusions Physical anthropomorphic phantom of pregnant patient can be manufactured using commercial materials and with low expenses. The files needed for 3D printing are now freely available. This enables further studies and comparison of numerical and physical experiments in diagnostic radiology or radiotherapy.

Year:

2023

Year:

2023

Year:

2022

Year:

2022

Year:

2022

Year:

2022

Year:

2022

Year:

2022

Year:

2021

Year:

2021

Year:

2021

Collaborators (4)

Ana Belchior

Professor Associado Convidado. Responsável pela UC de Efeitos Biológicos das Radiações

Universidade de Lisboa Instituto Superior Técnico

PORTUGAL
View details

Salvatore Di Maria

researcher

Instituto Superior Técnico

PORTUGAL
View details

Mladen Kasabasic

assistant professor (Biophysics and radiiology)

josip juraj strossmayer university of osijek

CROATIA
View details

Ivana Škrlec

Associate Professor

-

CROATIA
View details