Eamon Doyle
Assistant Professor of Clinical Radiology
Research Interests
Make your next move.
Prepare your application
Review drafts before you send them.
Explore related searches
About
Dr. Eamon Doyle is an Assistant Professor of Clinical Radiology at the University of Southern California Keck School of Medicine. His research focuses on quantitative susceptibility mapping and its application in clinical diagnostic imaging. He is dedicated to translating innovative imaging tools into high-volume clinical practice, enhancing diagnostic accuracy and patient care.
Articles (3)
BACKGROUND Phase-contrast MRI (PC-MRI) offers a rapid, noninvasive technique to directly quantify flow through ventricular shunts, and it serves as an adjunct MRI sequence to inform decision-making in complex postoperative settings. OBSERVATIONS A 19-year-old man with Dandy-Walker–associated hydrocephalus underwent proximal catheter exchange of a right-sided parietal ventriculoperitoneal shunt. Postoperatively, he developed intraventricular hemorrhage and symptomatic shunt occlusion and required emergency left frontal external ventricular drain (EVD) placement. After 5 days of drainage, the EVD was clamped and limited brain MRI with PC-MRI was performed. Shunt flow measured 21.2 ± 2.8 mL/hr, exceeding the patient’s prior mean EVD output of 12 ± 6.8 mL/hr. The lateral ventricles had returned to their presymptomatic size, and the patient’s symptoms resolved. These concordant findings supported shunt patency, enabling safe EVD removal, and no additional shunt surgery was required. LESSONS When ventricular size, pressure, and clinical status alone cannot conclusively establish ventricular shunt function, PC-MRI can supply a direct, quantitative measure of CSF flow. Incorporating this brief (60-second) sequence into surveillance imaging for patients with ventricular shunts may refine management decisions, avert unnecessary revisions, and improve patient safety. https://thejns.org/doi/10.3171/CASE25679
Year:
2026
Background Ventricular shunts divert cerebrospinal fluid (CSF) in patients with hydrocephalus, which can be lifesaving. Untreated shunt failure may lead to increased intracranial pressure and neurological injury. The process of diagnosing shunt malfunction can be complex, and historically, there has not been a simple method for noninvasive and quantitative measurement of CSF flow through shunts. The demonstration of successful clinical application of phase-contrast magnetic resonance imaging (PC-MRI) to noninvasively quantify shunt flow is relatively new and will benefit from standardization across varying types of magnetic resonance (MR) hardware to facilitate implementation at multiple medical sites. PC-MRI CSF flow measurement through ventricular shunts has not yet been compared across different types of MR hardware (ie, differing field strengths, radiofrequency coils, slew rates, gradient strengths, models, and manufacturers). Objective This study describes a protocol aimed to standardize and optimize PC-MRI shunt flow measurements for widespread use on any MR scanner. Methods To study shunt flow in a manner that would translate effectively to the patient care setting, a phantom model incorporating a human shunt catheter can be constructed to obtain data over a typical physiological range of CSF flow rates. Calibration curves are used to model data comparing known flow rates to flow measured via PC-MRI. The accuracy of each MR scanner is assessed using linear regression. This protocol will be repeated on 8 MR scanners before multisite data collection. Results The shunt flow phantom was constructed in November 2024. Single-site phantom calibration began in April 2025 and concluded in December 2025. Registration of clinical data collection sites will take place between November 2025 and July 2026. Approval from the Children’s Hospital of Los Angeles Institutional Review Board was obtained in January 2023 (before scanner calibration), and single-site data collection is ongoing. Multi-institutional clinical data collection will begin in July 2026 and continue until January 2027. Results and statistical analyses are expected by April 2027. Conclusions This study protocol provides a methodology to test and implement PC-MRI on any MR scanner using a phantom model that (1) represents real flow and catheter conditions, (2) provides a repeatable means for data collection, (3) is easy to assemble, (4) minimizes artifacts, and (5) is transportable. We also describe analytic methods for interscanner calibration across a range of hardware parameters and provide a framework for multisite data collection.
Year:
2026
Quantitative susceptibility mapping (QSM) is an MRI-based technique for iron quantification of targeted tissue. QSM provides information relevant to clinicians in a broad range of diagnostic contexts, including sickle cell disease, inflammatory/demyelinating processes, and neoplasms. However, major MRI vendors do not offer QSM post-processing in a form ready for general use. This work describes a vendor-agnostic approach for scaling QSM analysis from a research technique to a routine diagnostic test. We provide the details needed to seamlessly integrate hardware, software, and clinical systems to provide QSM processing for a busy clinical radiology workflow. This approach can be generalized to other advanced MRI acquisitions and analyses with proven diagnostic utility, yet without crucial MR vendor support.
Year:
2022
Collaborators (4)
Benita Tamrazi
University of Southern California
Pradip Chaudhari
University of Southern California
Jason Scott Hauptman
Assistant Professor
University of Washington
John C. Wood
University of Southern California