Emily McWalter
Has grant
Assistant Professor
Research Interests
Explore related searches
Contact this professor
Get a free first email built on one of their papers, ready for you to edit and send yourself.
About
Emily McWalter is an Assistant Professor at the University of Saskatchewan, Canada. Her research areas encompass advanced MRI techniques, including the design of flexible ultra-short echo time (FUSE) sequences and non-contrast imaging methods for assessing synovitis in the knee. Additionally, she investigates bone-cartilage mismatch in the medial tibial plateau through MRI studies. Her recent publications contribute significantly to the field of medical imaging and musculoskeletal disorders.
Recent Grants
Grant: Close
Robust Magnetic Resonance Imaging of Short T2 Tissues: Part 2
Open Date: 2020-01-01
Close Date: 2021-07-01
Grant: Close
Linking Joint Mechanics and Tissue Mechanics with MRI
Open Date: 2019-04-01
Close Date: 2020-03-31
Grant: Close
Impact of inactivity and exercise on muscle and bone marrow adiposity
Open Date: 2018-12-01
Close Date: 2020-05-31
Grant: Close
The Forgotten Tissues of Knee Osteoarthritis: Quantitative MRI of Synovium, Muscle, Tendons and Ligaments
Open Date: 2018-09-01
Close Date: 2021-08-31
Grant: Close
Intra-articular Pressure Measurement System
Open Date: 2018-04-01
Close Date: 2019-03-31
Articles (4)
Purpose To present the validation of a new Flexible Ultra‐Short Echo time (FUSE) pulse sequence using a short‐T 2 phantom. Methods FUSE was developed to include a range of RF excitation pulses, trajectories, dimensionalities, and long‐T 2 suppression techniques, enabling real‐time interchangeability of acquisition parameters. Additionally, we developed an improved 3D deblurring algorithm to correct for off‐resonance artifacts. Several experiments were conducted to validate the efficacy of FUSE, by comparing different approaches for off‐resonance artifact correction, variations in RF pulse and trajectory combinations, and long‐T 2 suppression techniques. All scans were performed on a 3 T system using an in‐house short‐T 2 phantom. The evaluation of results included qualitative comparisons and quantitative assessments of the SNR and contrast‐to‐noise ratio. Results Using the capabilities of FUSE, we demonstrated that we could combine a shorter readout duration with our improved deblurring algorithm to effectively reduce off‐resonance artifacts. Among the different RF and trajectory combinations, the spiral trajectory with the regular half‐inc pulse achieves the highest SNRs. The dual‐echo subtraction technique delivers better short‐T 2 contrast and superior suppression of water and agar signals, whereas the off‐resonance saturation method successfully suppresses water and lipid signals simultaneously. Conclusion In this work, we have validated the use of our new FUSE sequence using a short T 2 phantom, demonstrating that multiple UTE acquisitions can be achieved within a single sequence. This new sequence may be useful for acquiring improved UTE images and the development of UTE imaging protocols.
Year:
2023
Year:
2021
Year:
2021
Year:
2021
Collaborators (2)
Haron Obaid
University of Saskatchewan
Niranjan Venugopal
-
Make your next move.
Prepare your application
Review drafts before you send them.