Eric Laugeman
Research Interests
Explore related searches
Contact this professor
Get a free first email built on one of their papers, ready for you to edit and send yourself.
Articles (17)
Purpose The quality of on‐board imaging systems, including cone‐beam computed tomography (CBCT), plays a vital role in image‐guided radiation therapy (IGRT) and adaptive radiotherapy. Recently, there has been an upgrade of the CBCT systems fused in the O‐ring linear accelerators called HyperSight, featuring a high imaging performance. As the characterization of a new imaging system is essential, we evaluated the image quality of the HyperSight system by comparing it with Halcyon 3.0 CBCT and providing benchmark data for routine imaging quality assurance. Methods The HyperSight features ultra‐fast scan time, a larger kilovoltage (kV) detector, a more substantial kV tube, and an advanced reconstruction algorithm. Imaging protocols in the two modes of operation, treatment mode with IGRT and the CBCT for planning (CBCTp) mode were evaluated and compared with Halcyon 3.0 CBCT. Image quality metrics, including spatial resolution, contrast resolution, uniformity, noise, computed tomography (CT) number linearity, and calibration error, were assessed using a Catphan and an electron density phantom and analyzed with TotalQA software. Results HyperSight demonstrated substantial improvements in contrast‐to‐noise ratio and noise in both IGRT and CBCTp modes compared to Halcyon 3.0 CBCT. CT number calibration error of HyperSight CBCTp mode (1.06%) closely matches that of a full CT scanner (0.72%), making it suitable for adaptive planning. In addition, the advanced hardware of HyperSight, such as ultra‐fast scan time (5.9 s) or 2.5 times larger heat unit capacity, enhanced the clinical efficiency in our experience. Conclusions HyperSight represented a significant advancement in CBCT imaging. With its image quality, CT number accuracy, and ultra‐fast scans, HyperSight has a potential to transform patient care and treatment outcomes. The enhanced scan speed and image quality of HyperSight are expected to significantly improve the quality and efficiency of treatment, particularly benefiting patients.
Year:
2024
Year:
2024
Year:
2024
Year:
2024
Year:
2024
Year:
2024
Year:
2023
Year:
2023
Year:
2023
Year:
2023
Year:
2023
Year:
2023
Year:
2022
Year:
2022
Year:
2022
Year:
2022
Year:
2022
Collaborators (7)
Carl DeSelm
Assistant Professor
Washington University in St. Louis
Jiayi Huang
Assistant Profressor
Washington University in St. Louis
Hyun Kim
Washington University Physicians
Joshua Schiff
Assistant Professor of Clinical Radiation Oncology
University of Southern California
John Ginn
Assistant Professor
Duke University
Shahed Badiyan
University of Texas Southwestern Medical Center
Hugh Lee
-
Make your next move.
Prepare your application
Review drafts before you send them.