Eric Monnet
Professor, Small Animal Surgery
Research Interests
Make your next move.
Prepare your application
Review drafts before you send them.
Explore related searches
About
Professor Eric Monnet is a faculty member in the Department of Small Animal Surgery at Colorado State University, USA. His research areas include advanced laparoscopic techniques, integrated endoscopic procedures, and gastrointestinal surgery in canines and felines. His recent publications explore the efficacy of three-dimensional laparoscopy, innovative surgical approaches, and the physiological implications of various surgical treatments in small animals.
Articles (29)
Year:
2026
Year:
2026
Year:
2026
Year:
2026
Year:
2026
Objective To evaluate the feasibility of a commercial simulator to reproduce key steps of canine laparoscopic cholecystectomy, and to compare surgical performance when using 3-D versus 2-D visualization. Methods 16 gallbladder inserts mounted in a laparoscopic cholecystectomy model were used. Inserts were randomly assigned to 2-D or 3-D visualization groups and placed in a laparoscopic training box. All procedures were performed on a single day in 2022 by 1 American College of Veterinary Surgeons resident who completed prestudy training on the simulator to minimize learning-curve effects. A board-certified surgeon supervised all procedures. Surgical steps included cystic duct dissection, endoclip application, cystic duct transection, and gallbladder removal. Measured outcomes included surgical times for defined intervals, total procedure time, intraoperative complications, and residual simulated liver tissue attached to the gallbladder. Results Time from instrument insertion to first endoclip placement and total surgical time were significantly shorter with 3-D visualization compared to 2-D, and the differences in medians suggested clinically meaningful improvements in performance. There were no significant group differences in bile leakage, incomplete clipping, or the amount of residual foam attachment. Conclusions This physical simulator allowed reproduction of most key procedural steps in canine laparoscopic cholecystectomy. Three-dimensional visualization improved surgical efficiency for a trainee operator. Clinical Relevance The simulator provided a safe, accessible platform for early skills acquisition before progressing to cadaveric or clinical training.
Year:
2026
Objective To assess the feasibility of laparoscopic-assisted fluoroscopic cholangiography for visualizing the biliary system in canine cadavers. Methods 10 canine cadavers were used. Two 5-mm laparoscopic ports were placed via ventral midline incisions. An 8.5-French pigtail catheter was introduced percutaneously into the gallbladder lumen under laparoscopic guidance. Iohexol contrast medium, diluted in 3 different ratios, was injected, and fluoroscopic images were obtained using a C-arm fluoroscopy unit. Catheters were removed, and gallbladder walls were closed with intracorporeal suturing. Visibility of the cystic duct, hepatic ducts, and common bile duct was graded from excellent to not visible. Results Catheter placement was successful in all cadavers. Contrast leakage occurred in 4 cadavers. The common bile duct was graded excellent to good in 7 cadavers and not visible in 1, the cystic duct was excellent to good in 8, and the hepatic ducts were excellent to good in 6 and not visible in 2. The 1:2 iohexol dilution provided optimal visualization in this study. Catheter sites were successfully closed with intracorporeal suturing without observed bile leakage. Conclusions Laparoscopic-assisted fluoroscopic cholangiography is a feasible technique for biliary visualization in canine cadavers, particularly with a 1:2 iohexol dilution. Clinical Relevance This technique may provide a minimally invasive method for intraoperative biliary assessment in dogs, facilitating identification of anatomy and guidance of surgical procedures. Further studies in live patients are warranted to evaluate safety, effectiveness, and applicability in clinical cases.
Year:
2026
Background Minimally invasive surgery has made tremendous progress in the last two decades thanks to the more sophisticated instrumentation, new entry ports, vessel sealant devices, and ultrasound dissectors. Cameras and monitors are now high‐definition or 4 K, increasing the clarity of the image available to the surgeon. Those progresses have made minimally invasive surgery safer. However, the biggest challenge of minimally invasive surgery is the lack of depth perception, which requires the surgeon's brain to recreate a three‐dimensional (3D) image using cues in the field. The development of 3D cameras enable surgeons to have a more realistic depth perception. The development of the third generation of 3D cameras, combined with light‐polarizing glasses, resolved the problem of dizziness experienced by surgeons during long and complicated procedures. Aims To review the evidence from human and veterinary surgery regarding the benefits of 3D visualization during laparoscopy. Conclusions and implications The evidence suggests that 3D visualization enhances depth perception, safety, a smoother learning curve, and overall wellness for surgeons. Some controversies persist on the clinical benefit of 3D visualization, even if most of the studies showed statistically significant reduction of operating time, estimated blood loss, operating errors, and shorten hospital stay in human patients.
Year:
2025
Year:
2025
Objective To evaluate the feasibility of minimally invasive integrated endoscopic mini‐hemilaminectomy and thoracolumbar lateral corpectomy at six intervertebral disc spaces in the canine thoracolumbar vertebral column. Study design Experimental, randomized cadaveric study. Animals Eight cadaver dogs euthanized for reasons unrelated to this study. Methods Preoperative computed tomography (CT) scans were performed for surgical planning. Using an endoscopic system, mini‐hemilaminectomy and thoracolumbar lateral corpectomy were performed from the T11–12 through L3–4 intervertebral disc spaces, with cadavers in sternal recumbency or positioned at a 30°–60° angle. Postoperative CT scans were used to measure corpectomy dimensions as a percentage of total vertebral dimensions. Results Median ± interquartile range (IQR) corpectomy dimensions were 23.07% ± 16.47% of vertebral body length, 46.76% ± 21.7% of vertebral body height, and 74.44% ± 47.37% of vertebral canal diameter. Targeted dimensions were achieved at all surgical sites from T11–12 through L3–4. Conclusion Integrated endoscopic thoracolumbar lateral corpectomy was successfully performed at all intervertebral disc spaces from T11–12 through L3–4 using an endoscopic system, although thoracic sites required more practice. Clinical significance This pilot study will guide further clinical applications of minimally invasive neurosurgery in small animal patients.
Year:
2025
Year:
2025
Year:
2025
Year:
2025
Year:
2025
Year:
2024
Year:
2024
Year:
2024
Year:
2024
Year:
2024
Year:
2023
Year:
2023
Year:
2022
Year:
2022
Year:
2022
Year:
2022
Year:
2021
Year:
2021
Year:
2021
Year:
2021
Collaborators (1)
Shiori Arai
Associate Professor
Colorado State University
Make your next move.
Prepare your application
Review drafts before you send them.