Black Friday saleEnds in00h00m00s

annual Pro

Ervin Rácz Dr

Head of Department/ Head of Institute

Óbuda University
Country flagHungary

Research Interests

ApplyKite TwinLearns as you apply

Make your next move.

Prepare your application

Review drafts before you send them.

Explore related searches

Articles (6)

Year:

2026

This study presents and systematizes a high-reliability measurement and technological dataset suitable for prediction-based validation of the Spent Fuel Interim Storage Facility (SFISF) of the Paks Nuclear Power Plant. The primary objective of this dataset is not the validation of a general-purpose software tool, but to establish a reproducible experimental basis for the objective and quantitative validation of a three-dimensional, facility-scale heat transfer and buoyancy-driven flow model of the SFISF, developed using the finite difference method (FDM), in a passively cooled system where heat conduction, thermal radiation, and natural convection simultaneously occur. The applied measurement systems (SMAS, CTRS, and the in-house developed CFEPR), their spatial arrangement, accuracy characteristics, as well as data post-processing and the generation of model execution inputs are described in detail. Special emphasis is placed on the functional separation of the available data into initialization data, model execution data, and independent validation datasets, ensuring that model assessment does not rely on calibration or parameter fitting. Furthermore, the estimation of decay heat generated by the stored fuel assemblies is presented using both a standard correlation method (ANSI/ANS-5.1) and isotope inventory-based calculations, and the discrepancies between these approaches are treated as input uncertainties and sensitivity analysis factors. The spectral solar load is considered based on the ASTM G-173 reference spectrum, while during cloudy periods an effective irradiance estimation derived from on-site lux measurements is applied. The results indicate that the available measurement and technological information is sufficient for supporting reproducible, transparent, and quantitative validation studies of the three-dimensional numerical model of the SFISF, as well as for assessing the impact of dominant input uncertainties.

Year:

2026

Year:

2025

This article presents an optimization of the explicit Euler method for a heat conduction model. The starting point of the paper was the analysis of the limitations of the explicit Euler scheme and the classical CFL condition in the transient domain, which pointed to the oscillation occurring in the intermediate states. To eliminate this phenomenon, we introduced the No-Sway Threshold given for the Fourier number (K), stricter than the CFL, which guarantees the monotonic approximation of the temperature–time evolution. Thereafter, by means of the identical inequalities derived based on the Method of Equating Coefficients, we determined the optimal values of Δt and Δx. Finally, for the construction of the variable grid spacing (M2), we applied the equation expressing the R of the identical inequality system and accordingly specified the thickness of the material elements (Δξ). As a proof-of-concept, we demonstrate the procedure on an application case with major simplifications: during an emergency shutdown of the Flexblue® SMR, the temperature of the air inside the tank instantly becomes 200 °C, while the initial temperatures of the water and the steel are 24 °C. For a 50.003 mm × 50.003 mm surface patch of the tank, we keep the leftmost and rightmost material elements of the uniform-grid (M1) and variable-grid (M2) single-line models at constant temperature; we scale the results up to the total external surface (6714.39 m2). In the M2 case, a larger portion of the heat power taken up from the air is expended on heating the metal, while the rise in the heat power delivered to the seawater is more moderate. At the 3000th min, the steel-wall temperature in M1 falls between 26.229 °C and 25.835 °C, whereas in M2 the temperature gradient varies between 34.648 °C and 30.041 °C, which confirms the advantage of the combination of variable grid spacing and the No-Sway Threshold.

Year:

2025

Year:

2025

Year:

2024