Eva Wittenmeier

Johannes Gutenberg Universität Mainz
Country flagGermany

Research Interests

Explore related searches

Contact this professor

Get a free first email built on one of their papers, ready for you to edit and send yourself.

Articles (10)

Year:

2024

Year:

2024

Year:

2023

Year:

2023

Introduction Continuously assessing the oxygenation levels of patients to detect and prevent hypoxemia can be advantageous for safe anesthesia, especially in neonates and small infants. The oxygen reserve index (ORI) is a new parameter that can assess oxygenation through a relationship with arterial oxygen partial pressure (PaO 2 ). The aim of this study was to examine whether the ORI provides a clinically relevant warning time for an impending SpO 2 (pulse oximetry hemoglobin saturation) reduction in neonates and small infants. Methods ORI and SpO 2 were measured continuously in infants aged <2 years during general anesthesia. The warning time and sensitivity of different ORI alarms for detecting impending SpO 2 decrease were calculated. Subsequently, the agreement of the ORI and PaO 2 with blood gas analyses was assessed. Results The ORI of 100 small infants and neonates with a median age of 9 months (min–max, 0–21 months) and weight of 8.35 kg (min–max, 2–13 kg) were measured. For the ORI/PaO 2 correlation, 54 blood gas analyses were performed. The warning time and sensitivity of the preset ORI alarm during the entire duration of anesthesia were 84 s (25th–75th percentile, 56–102 s) and 55% (95% CI 52%–58%), and those during anesthesia induction were 63 s (40–82 s) and 56% (44%–68%), respectively. The positive predictive value of the preset ORI alarm were 18% (95% CI 17%–20%; entire duration of anesthesia) and 27% (95% CI 21%–35%; during anesthesia induction). The agreement of PaO 2 intervals with the ORI intervals was poor, with a kappa of 0.00 (95% CI = [−0.18; 0.18]). The weight ( p = .0129) and height ( p = .0376) of the infants and neonates were correlated to the correct classification of the PaO 2 interval with the ORI interval. Conclusions The ORI provided an early warning time for detecting an impending SpO 2 decrease in small infants and neonates in the defined interval in this study. However, the sensitivity of ORI to forewarn a SpO 2 decrease and the agreement of the ORI with PaO 2 intervals in this real‐life scenario were too poor to recommend the ORI as a useful early warning indicator for this age group.

Year:

2023

Year:

2023

Year:

2023

Year:

2023

Year:

2022

Year:

2022

Collaborators (6)

Nina Pirlich

-

GERMANY
View details

Ruediger Noppens

Western University

CANADA
View details

Florian Piekarski

University Hospital Bonn

GERMANY
View details

Susan Marie Goobie

Associate Professor

Harvard Medical School

UNITED STATES
View details

Jost Kaufmann

Private Universität Witten/Herdecke gGmbH

GERMANY
View details

Kristin Engelhard

Johannes Gutenberg Universität Mainz

GERMANY
View details
ApplyKite TwinLearns as you apply

Make your next move.

Prepare your application

Review drafts before you send them.