Felix Christian Kohler

Jena University Hospital
Country flagGermany

Research Interests

Explore related searches

Contact this professor

Get a free first email built on one of their papers, ready for you to edit and send yourself.

Articles (8)

Year:

2024

The hook test is a widely used intraoperative method for assessing syndesmosis stability. However, there are no recommendations regarding the force required to perform this test. Furthermore, the reliability of the test is unclear. Ten experienced surgeons performed hook tests on a cadaver bone model. The applied forces were recorded in a blinded manner. In addition, standardized hook tests with defined forces (50, 80, and 100 N) were performed on 10 pairs of cadaver lower legs and the syndesmosis was sequentially destabilized. Diastasis of the syndesmosis was recorded using an optical 3D camera system. A median force of 81 N (Range: 50 N–145 N) was applied. A proportion of 82% of the tests showed a force < 100 N. The data showed good intraraterreliability and poor interraterreliability. In the standardized investigation of the hook test on the cadaver bone model, both the force and the instability of the syndesmosis had a significant influence on the syndesmosis diastasis. Nevertheless, even with maximum instability of the syndesmosis, diastasis > 2 mm could only be measured in 12 of the 19 evaluable specimens. The widely used hook test shows a high variability when performed in practice. Even in a standardized manner, the hook test cannot detect a relevant syndesmosis injury.

Year:

2023

Plantar plate positioning has been demonstrated as biomechanically superior. However, some operators remain resentful about the morbidity of the surgical approach. To provide improved plate fixation for first tarsometatarsal joint arthrodesis with respect to the tibialis anterior tendon, a medio-plantar plate was developed. The purpose of this biomechanical study was to compare its construct stability to that of a plantar plate construct. Twelve pairs of fresh frozen human specimens were used in a matched pair test. Each pair was fixed with a 4 mm compression screw and either a plantar locking plate or a medio-plantar locking plate. A cantilever beam test was performed in dorsiflexion. Before and after cyclic loading (5000 cycles; 40 N), bending stiffness and relative movements at the joint space were monitored in a quasi-static test including optical motion tracking. Maximum load and bending moment to failure were investigated in a load-to-failure ramp test. The bending stiffness of both groups did not significantly differ before (plantar 49.9 N/mm ± 19.2; medio-plantar 53.9 N/mm ± 25.4, p = 0.43) or after (plantar 24.4 N/mm ± 9.7; medio-plantar 35.3 N/mm ± 22.0, p = 0.08) cyclic loading but decreased significantly in both groups (p < 0.01) after cyclic loading. Relative movement increased significantly during cyclic testing in both groups (p < 0.01) but did not differ significantly between the groups before (p = 0.29) or after (p = 0.16) cyclic loading. Neither load nor bending moment to failure were significantly different (plantar 225 N ± 78, 10.8 Nm; medio-plantar 210 N ± 86, 10.1 Nm, p = 0.61). Both plate constructs provided equivalent construct stability, both being well suited for Lapidus arthrodesis.

Year:

2023

Year:

2023

Year:

2023

Year:

2022

Year:

2022

Year:

2022

Collaborators (3)

Mark Lenz

Jena University Hospital

GERMANY
View details

Jakob Hallbauer

Jena University Hospital

GERMANY
View details

Britt Wildemann

-

GERMANY
View details
ApplyKite TwinLearns as you apply

Make your next move.

Prepare your application

Review drafts before you send them.