Florian Grüner
professor
Research Interests
Make your next move.
Prepare your application
Review drafts before you send them.
Explore related searches
Articles (4)
Background: Gold nanoparticles (GNPs) are widely used in nanomedicine as drug carriers, including in targeted radionuclide therapy where therapeutic radionuclides are bound to GNPs. Quantitative assessment of their biodistribution is essential. X-ray fluorescence imaging (XFI) is well suited for detecting high-Z elements, but its quantitative accuracy is compromised by strong attenuation effects, particularly in L-shell XFI where low-energy fluorescence (~10 to 12 keV) is heavily absorbed in tissue. Methods: We developed a computed tomography (CT)-guided attenuation correction algorithm for L-shell XFI. The method generates energy-dependent attenuation maps from co-registered CT data and performs voxel-wise corrections along both excitation and emission paths. The approach was tested on an ex vivo murine tumor sample resected three hours after intratumoral injection of 34.7 μg PEG-modified GNPs. Results: Application of the CT-guided correction substantially improved the relative accuracy of L-shell XFI reconstructions compared to uncorrected data. The corrected distribution maps showed consistent mass recovery across different measurement geometries, demonstrating that the algorithm compensates for the theoretically expected attenuation due to heterogeneous biological tissue. Conclusions: This study provides a proof-of-principle that CT-based attenuation correction enables more reliable and quantitative L-shell XFI of GNPs in biological samples. The approach represents a promising step toward accurate nanoparticle biodistribution assessment in biomedical research, including preclinical studies in targeted radionuclide therapy.
Year:
2025
We demonstrate a method to characterize the beam energy, transverse profile, charge, and dose of a pulsed electron beam generated by a 1 kHz TW laser-plasma accelerator. The method is based on imaging with a scintillating screen in an inhomogeneous, orthogonal magnetic field produced by a wide-gap magnetic dipole. Numerical simulations were developed to reconstruct the electron beam parameters accurately. The method has been experimentally verified and calibrated using a medical LINAC. The energy measurement accuracy in the 6–20 MeV range is proven to be better than 10%. The radiation dose has been calibrated by a water-equivalent phantom, RW3, showing a linear response of the method within 2% in the 0.05–0.5 mGy/pulse range.
Year:
2024
Prostate cancer is the second most commonly diagnosed cancer in men worldwide. Despite this, current diagnostic tools are still not satisfactory, lacking sensitivity for early-stage or single-cell diagnosis. This study describes the development of small-molecule tracers for the well-known tumor marker prostate-specific membrane antigen (PSMA). These tracers contain a urea motif for PSMA-targeting and iodinated aromatic moieties to allow detection via X-ray fluorescence imaging (XFI). Tracers with a triiodobenzoyl moiety allowed the specific targeting and successful imaging of PSMA+ cell lines with XFI. The XFI-measured uptake of 7.88 × 10−18 mol iodine (I) per cell is consistent with the uptake of known PSMA tracers measured by other techniques such as inductively coupled plasma mass spectrometry (ICP-MS). This is the first successful application of XFI to tumor cell targeting with a small-molecule tracer. In addition, iodinated tracers were used for the characterization of quantum dots (QDs) conjugated to PSMA-targeting urea motifs. The resulting targeted QD conjugates were shown to selectively bind PSMA+ cell lines via confocal microscopy. The immobilized iodinated targeting vectors allowed the determination of the tracer/QD ratio via XFI and ICP-MS. This ratio is a key property of targeted particles and difficult to measure by other techniques.
Year:
2024
This work for the first time addresses the feasibility of measuring millihertz gravitational waves (mHz GWs) with a storage ring-based detector. While this overall challenge consists of several partial problems, here we focus solely on quantifying design limitations imposed by the kinetic energy and radiated power of circulating ions at relativistic velocities. We propose an experiment based on the measurement of the time-of-flight signal of an ion chain. One of the dominant noise sources inherent to the measurement principle for such a GW detector is the shot noise of the emitted synchrotron radiation. We compute the noise amplitude of arrival time signals obtained by analytical estimates and simulations of ions with different masses and velocities circulating in a storage ring with the circumference of the Large Hadron Collider. Thereby, we show that our experiment design could reduce the noise amplitude due to the synchrotron radiation in the frequency range 10 − 4 – 10 − 2 Hz to one or two orders of magnitude below the expected GW signals from of astrophysical sources, such as supermassive binary black holes or extreme mass-ratio inspirals. Other key requirements for building a working storage ring-based GW detector include the generation and acceleration of heavy ion chains with the required energy resolution, their injection and continued storage, as well as the detection method to be used for the determination of the particle arrival time. However, these are not the focus of the work presented here, in which we instead concentrate on the definition of a working principle in terms of ion type, kinetic energy, and ring design, which will later serve as a starting point when addressing a more complete experimental setup. Published by the American Physical Society 2024
Year:
2024
Collaborators (7)
Wolfgang Hillert
Universität Hamburg
Pavel Bakule
Department Head
Extreme Light Infrastructure ERIC
Marcus Brüggen
Universität Hamburg
Giovanni Francesco Tassielli
Associate Professor in experimental particle physics (PHYS/01)
Mercatorum University
Jochen Liske
Professor of Observational Astronomy
Universität Hamburg
Koichi Fukase
Professor
Osaka University
Kazuya Kabayama
Osaka University
Make your next move.
Prepare your application
Review drafts before you send them.