Frank Wendler

Country flagGermany

Research Interests

Explore related searches

Contact this professor

Get a free first email built on one of their papers, ready for you to edit and send yourself.

Articles (5)

BaTiO3 is a well-known piezoelectric material with commercial uses. The ferroelectric state of BaTiO3 generally comprises electrically polarized domains separated by domain walls (DWs). The DW alters local polarization vectors by an angle of 90° for 90° DW or 180° for 180° DW. The DW is crucial to piezoelectric properties such as response time and fatigue. Furthermore, the DW structure and its dynamics in BaTiO3 are not well understood. Hence, for the first time, we theoretically obtained the atomistic structure of the 90° DW via molecular dynamics simulations at 300 K with the core–shell interatomic potential, using a large-scale system with a side length of 2.8×103Å. The width of the 90° DW thereby obtained was approximately 30 Å, which was 20 Å wider than that of the 180° DW. Under the external electric field E→ext parallel to the DW, we observed an extension of a domain having a polarization vector with a positive component along the E→ext-direction. The migration velocity of the 90° DW was approximately two times that of the 180° DW at the same Eext in the range 7–20MV/m. For Eext≥15MV/m, the migration velocity of the 90° DW in the direction with a positive component along the polarization vector of the extending domain was substantially higher than that in the opposite direction. The physical causes of the difference in the migration velocities of the 90° DW in the two directions were analyzed.

Year:

2023

Numerous attachment systems exist for implant-supported overdentures, with each having specific limitations in terms of retention, cost, wear, maintenance and cleanability. A retrospective analysis of patients restored with implant-supported overdentures using bars, telescopic crowns and Locator-type attachments was performed and the patients were interviewed. An in vitro strain gauge study compared telescopic crowns, Locator-type attachments and a novel flexible attachment system employing a shape memory alloy (NiTi) with respect to peri-implant strain development during insertion, loading and removal of an overdenture. A significantly lower number of attachment-related complications was observed in bars as compared to telescopic crowns (p = 0.00007) and Locator-type attachments (p = 0.00000), respectively. Greater overall patient satisfaction was noted in bar-retained restorations while Locator-type attachments led to lower levels of satisfaction regarding prosthesis retention. In vitro, telescopic crowns caused maximum strain development during prosthesis insertion and loading, while during removal this was observed in Locators with white retentive inserts. NiTi attachments caused significantly lower strain development during insertion as compared to telescopic crowns (p = 0.027). During loading, NiTi attachments caused significantly lower strain development than Locators with blue retentive inserts (p = 0.039). During removal, NiTi attachments caused significantly less strain development as compared to Locators with white retentive inserts (p = 0.027). Positional discrepancies between male and female attachment parts affected the retention and reaction force between both components, which may be minimized by using the novel NiTi attachment system. This may be beneficial in terms of component wear and implant loading.

Year:

2023

Year:

2022

Year:

2022

Year:

2021

Collaborators (2)

Manfred Kohl

Professor

Karlsruhe Institute of Technology

GERMANY
View details

Matthias Karl

Saarland University

GERMANY
View details
ApplyKite TwinLearns as you apply

Make your next move.

Prepare your application

Review drafts before you send them.