Gary Shum
Has grant
Professor
Research Interests
Explore related searches
Contact this professor
Get a free first email built on one of their papers, ready for you to edit and send yourself.
About
Professor Gary Shum is a faculty member at the University of St Mark and St John in the UK. His research interests are focused on ophthalmology and biomechanics, with recent articles exploring topics such as intraocular lens performance, running biomechanics across different age groups, and the impact of footwear on running efficiency. He is actively engaged in studies that aim to enhance understanding of visual function post-surgery as well as the effects of training techniques in athletic performance.
Recent Grants
Grant: Close
Muscle Stress Relief: An integrated research program linking together basic research on secondary myopathies in stress states to innovative translation in applied myology.
Open Date: 2016-03-01
Close Date: 2020-02-29
Articles (10)
Introduction To establish the most appropriate curve fitting method to allow accurate comparison of defocus curves derived from intraocular lenses (IOLs). Methods Defocus curves were plotted in five IOL groups (monofocal, extended depth of focus, refractive bifocal, diffractive bifocal and trifocal). Polynomial curves from 2nd to 11th order and cubic splines were fitted. Goodness of fit (GOF) was assessed using five methods: least squares, coefficient of determination ( R 2 adj ), Akaike information criteria (AIC), visual inspection and Snedecor and Cochran. Additional defocus steps at −2.25 D and −2.75 D were measured and compared to the calculated visual acuity (VA) values. Area under the defocus curve and range of focus were also compared. Results Goodness of fit demonstrated variable results, with more lenient methods such as R 2 adj leading to overfitting and conservative methods such as AIC resulting in underfitting. Furthermore, conservative methods diminished the inflection points resulting in an underestimation of VA. Polynomial of at least 8th order was required for comparison of area methods, but overfitted the EDoF and monofocal groups; the spline curve was consistent for all IOLs and methods. Conclusions This study demonstrates the inherent difficulty of selecting a single polynomial function. The R 2 method can be used cautiously along with visual inspection to guard against overfitting. Spline curves are suitable for all IOLs, guarding against the issues of overfitting. Therefore, for analysis of the defocus profile of IOLs, the fitting of a spline curves is advocated and should be used wherever possible.
Year:
2022
Year:
2022
Year:
2021
Year:
2021
Year:
2021
Year:
2021
Year:
2020
Year:
2020
Year:
2020
Year:
2020
Collaborators (2)
Phillip J Buckhurst
-
Antonios Stavropoulos-Kalinoglou
Leeds Beckett University
Make your next move.
Prepare your application
Review drafts before you send them.