Hendrik von Tengg-Kobligk
Has grant
Chief Attending
Research Interests
Explore related searches
Contact this professor
Get a free first email built on one of their papers, ready for you to edit and send yourself.
Recent Grants
Grant: Close
Automated segmentation of complex bone fractures from CT images (102.888 IP-LS)
Open Date: 2023-07-01
Close Date:
Grant: Close
Understanding drug resistance by turning metal-based anticancer therapeutics
Open Date: 2022-05-01
Close Date:
Grant: Close
SmaRaGD - Smart Radiology Goes Digital Digitalisierung der Radiologie mit KI-unterstützen strukturierten Befunden und Anamnese-Chatbot
Open Date: 2021-01-01
Close Date:
Grant: Close
Smart digital monitoring of abdominal aortic aneurysms (SmartLyf)
Open Date: 2020-06-01
Close Date: 2022-11-01
Grant: Close
Disease-targeted next generation sequencing panel (VASCSequ) for detection of somatic-mosaic mutations in congenital vascular malformations to enable further advance in personalised therapeutic decision making
Open Date: 2020-06-01
Close Date: 2023-05-01
Articles (10)
Year:
2024
Type-B aortic dissection is a cardiovascular disease in which a tear develops in the intimal layer of the descending aorta, allowing pressurized blood to delaminate the layers of the vessel wall. In medically managed patients, long-term aneurysmal dilatation of the false lumen (FL) is considered virtually inevitable and is associated with poorer disease outcomes. While the pathophysiological mechanisms driving FL dilatation are not yet understood, haemodynamic factors are believed to play a key role. Computational fluid dynamics (CFD) and 4D-flow MRI (4DMR) analyses have revealed correlations between flow helicity, oscillatory wall shear stress and aneurysmal dilatation of the FL. In this study, we compare CFD simulations using a patient-specific, three-dimensional, three-component inlet velocity profile (4D IVP) extracted from 4DMR data against simulations with flow rate-matched uniform and axial velocity profiles that remain widely used in the absence of 4DMR. We also evaluate the influence of measurement errors in 4DMR data by scaling the 4D IVP to the degree of imaging error detected in prior studies. We observe that oscillatory shear and helicity are highly sensitive to inlet velocity distribution and flow volume throughout the FL and conclude that the choice of IVP may greatly affect the future clinical value of simulations.
Year:
2023
Year:
2023
Year:
2022
Year:
2022
Year:
2022
Year:
2022
Year:
2022
Year:
2022
Year:
2022
Collaborators (5)
Bernd Jung
University Hospital of Bern
V. Díaz-Zuccarini
University College London
Adrian Thomas Huber
Inselspital Universitätsspital Bern
stavroula balabani
Professor
University College London
Moritz Tannast
Professor and Chairman
University of Fribourg
Make your next move.
Prepare your application
Review drafts before you send them.