Iqbal Jaffer
Research Interests
Make your next move.
Prepare your application
Review drafts before you send them.
Explore related searches
Articles (11)
Year:
2026
Year:
2026
Year:
2025
Year:
2025
Year:
2025
Background The feasibility of valve‐in‐valve transcatheter aortic valve replacement (ViV‐TAVR) after surgical aortic valve replacement (SAVR) and the impact of aortic root enlargement (ARE) remain unclear. This study assesses the anatomical feasibility of Viv TAVR post‐SAVR, with and without ARE through detailed pre‐ and postoperative gated CT scans. Methods We analyzed 62 patients undergoing SAVR ( n = 31) or SAVR + ARE ( n = 31) between September 2022 and May 2024. Pre‐ and postoperative gated CT scans were used to measure annular area, sinus of Valsalva (SOV) dimensions, coronary heights, and virtual valve‐to‐coronary (VTC) and valve‐to‐sinotubular junction (VTSTJ) distances. High‐risk ViV‐TAVR anatomy was defined as VTC < 4 mm or VTSTJ < 2 mm. Four enlargement techniques were used (Y‐Incision, Manouguian, Nicks and replacement of the coronary sinus). Results Female patients were more prevalent in the SAVR + ARE group (61% vs. 19.4%, p < 0.001). Preoperatively and compared to the SAVR cohort, SAVR + ARE had a smaller annular area‐derived diameter (23 ± 2 mm vs. 26.8 ± 2.2 mm, p < 0.001) and SOV dimensions (28.8 ± 2 vs. 32.8 ± 3.6, p ≤ 0.001) and, both cohorts had coronary heights of ≥ 14 mm. Postoperatively, both groups had a significant reduction in coronary heights by at least 7–9 mm ( p < 0.001). On the contrary, the SOV dimension increased significantly by +3 mm in the SAVR + ARE group (< 0.001), while it decreased numerically in the SAVR‐only cohort (0.07). Similarly, the majority of both groups were considered low risk for future ViV TAVR (SAVR: 24/31, 74%) and (SAVR + ARE: 22/31, 71%), while 22.6% (7/31) of SAVR and 29% (9/31) of SAVR + ARE were considered anatomically high risk. Conclusion While most patients who had SAVR, with or without ARE, were anatomically feasible for ViV TAVR, postoperative CT scans identified high‐risk anatomy in approximately 25% of cases. Pre‐ and post‐SAVR CT imaging offers insights into surgical planning and lifetime management of aortic valve disease.
Year:
2025
Background The anatomic substrate of bicuspid valves may lead to suboptimal TAVR stent expansion and geometry. Aim We evaluated determinants of stent geometry in bicuspid valves treated with Sapien transcatheter aortic valve replacement (TAVR) valves. Methods A multicenter retrospective registry of patients (February 2019 to August 2022) who underwent post‐TAVR computed tomography to determine stent area (vs. nominal valve area) and stent ellipticity (maximum diameter/minimum diameter). Predictors of relative stent expansion (minimum area/average of inflow + outflow area) and stent ellipticity were evaluated in a multivariable regression model, including valve calcium volume (indexed by annular area), presence of raphe calcium, sinus diameters indexed by area‐derived annular diameter, and performance of pre‐dilation and post‐dilation. Results The registry enrolled 101 patients from four centers. The minimum stent area (vs. nominal area) was 88.1%, and the maximum ellipticity was 1.10, with both observed near the midframe of the valve in all cases. Relative stent expansion ≥90% was observed in 64/101 patients. The only significant predictor of relative stent expansion ≥90% was the performance of post‐dilation (OR: 4.79, p = 0.018). Relative stent expansion ≥90% was seen in 86% of patients with post‐dilation compared to 57% without ( p < 0.001). The stent ellipticity ≥1.1 was observed in 47/101 patients. The significant predictors of stent ellipticity ≥1.1 were the indexed maximum sinus diameter (OR: 0.582, p = 0.021) and indexed intercommisural diameter at 4 mm (OR: 2.42, p = 0.001). Stent expansion has a weak negative correlation with post‐TAVR mean gradient ( r = −0.324, p < 0.001). Conclusion Relative stent expansion ≥90% was associated with the performance of post‐dilation, and stent ellipticity ≥1.1 was associated with indexed intercommisural diameter and indexed maximum sinus diameter. Further studies to determine optimal deployment strategies in bicuspid valves are needed.
Year:
2024
Year:
2024
Year:
2023
Year:
2023
Year:
2023
Collaborators (10)
Elif Bilgic
Assistant Professor and Education Scientist
McMaster University
Sophocles Voineskos
McMaster University
Quang N. Ngo
Associate Professor
McMaster University
Sam Schulman
Professor
McMaster University
carlos cordoba
Université de Montréal
Ahmad Kaviani
Assistant professor
Université de Montréal
Neevya Balasubramaniam
McGill University
Matthew Sibbald
-
Trisha Tee
McGill University
Andrew Farah
McGill University
Make your next move.
Prepare your application
Review drafts before you send them.