Meet ApplyKite Twin, the application assistant that learns with you
Meet your Twin, it learns with you
Your Twin learns with you
Launch week codes:30% off annual Pro20% off monthly Pro
Ends in00h00m00s
Ends in00h00m00s
J. Seth Eaton
Clinical Associate Professor, Comparative Ophthalmology
Research Interests
Make your next move.
Prepare your application
Review drafts before you send them.
Explore related searches
About
J. Seth Eaton is an Assistant Clinical Professor in Comparative Ophthalmology at the University of Wisconsin Madison, USA. His research focuses on the evaluation of intraocular materials, gene delivery methods, and anesthesia techniques in veterinary ophthalmology. Recent publications include studies on intraocular pressure management in cats and the clinicopathologic profiles of ocular conditions in dogs.
Articles (11)
Year:
2026
Year:
2025
Year:
2024
Year:
2024
Year:
2024
Year:
2023
Objective Cataract surgery remains the sole method to resolve blindness secondary to cataract formation. One complication includes fibrin web formation post‐operatively. This study aimed to investigate the presence of endotoxin within materials used during cataract surgery as a possible cause of fibrin web phenomenon. Methods Preservative‐free epinephrine, heparin, viscoelastic devices, and intraocular lenses were collected for evaluation. Various manufacturers and manufacturing lot numbers were used when available. Viscosity of viscoelastics was reduced by incubating samples with human recombinant hyaluronidase. Intraocular product (IOL) packaging fluid was collected and stored for testing. The IOLs were then washed with a sterile balanced salt solution, incubated at 37°C for 48 h, and then fluid was collected for testing to mimic intraocular placement. Samples were tested using a commercially available rFC kit. Fluorescence was measured at time zero and after 1 h using a fluorescence microplate reader. The change in fluorescence was corrected for blank fluorescence and plotted to a standard curve. Results Endotoxin levels were below the limit of detection (0.05 EU/mL) in all samples. Incubation of IOLs at intraocular temperature did not increase extraction of endotoxin. Conclusion Endotoxin was not identified in any tested sample, including those used in cases of fibrin web formation post‐phacoemulsification. As fibrin webs are often observed episodically, it is possible that endotoxin levels may vary between batches, or that endotoxin is not related to fibrin formation.
Year:
2023
Year:
2023
Year:
2022
Year:
2021
Year:
2020
Collaborators (4)
Ellison Bentley
-
Lara Tomich
Assistant Teaching Professor
University of Wisconsin-Madison
Vanessa Yang
Cummings School of Veterinary Medicine at Tufts University
Julie Kiland
Researcher III
University of Wisconsin-Madison
Make your next move.
Prepare your application
Review drafts before you send them.