James Jester

Has grant

Professor

University of California, Irvine
Country flagUnited States

Research Interests

ApplyKite TwinLearns as you apply

Make your next move.

Prepare your application

Review drafts before you send them.

Explore related searches

Recent Grants

Grant: Close

Non-linear Optical Collagen Cross-linking (NLO CXL) for Treatment of Keratoconus.

Open Date: 2014-08-01

Close Date: 2019-07-31

Grant: Close

Age-Related Meibomian Gland Dysfunction

Open Date: 2011-09-30

Close Date: 2021-05-31

Grant: Close

KERATOCYTE CRYSTALLIN PROTEINS AND CORNEAL TRANSPARENCY

Open Date: 2000-09-01

Close Date: 2004-08-31

Grant: Close

EYE RESEARCH INSTRUMENTATION

Open Date: 1987-09-30

Close Date: 1988-09-29

Grant: Close

Role of TGFbeta in Corneal Stromal Wound Healing

Open Date: 1987-09-30

Close Date: 2012-04-30

Articles (9)

Year:

2025

Year:

2024

Background and Objectives Femtosecond laser trabeculotomy (FLT) creates aqueous humor outflow channels through the trabecular meshwork (TM) and is an emerging noninvasive treatment for open‐angle glaucoma. The purpose of this study is to investigate the effect of pulse energy on outflow channel creation during FLT. Materials and Methods An FLT laser (ViaLase Inc.) was used to create outflow channels through the TM (500 μm wide by 200 μm high) in human cadaver eyes using pulse energies of 10, 15, and 20 μJ. Following treatment, tissues were fixed in 4% paraformaldehyde. The channels were imaged using optical coherence tomography (OCT) and assessed as full thickness, partial thickness, or not observable. Results Pulse energies of 15 and 20 μJ had a 100% success rate in creating full‐thickness FLT channels as imaged by OCT. A pulse energy of 10 μJ resulted in no channels ( n = 6), a partial‐thickness channel ( n = 2), and a full‐thickness FLT channel ( n = 2). There was a statistically significant difference in cutting widths between the 10 and 15 μJ groups ( p < 0.0001), as well as between the 10 and 20 μJ groups ( p < 0.0001). However, there was no statistically significant difference between the 15 and 20 μJ groups ( p = 0.416). Conclusions Fifteen microjoules is an adequate pulse energy to reliably create aqueous humor outflow channels during FLT in human cadaver eyes. OCT is a valuable tool when evaluating FLT.

Year:

2024

Year:

2024

Year:

2024

Year:

2024

Year:

2024

Year:

2023

Year:

2023

Collaborators (3)

Shangbang Luo

Oregon Health & Science University

UNITED STATES
View details

Daniel Saban

Distinguished Professor

Duke University

UNITED STATES
View details

Andrew JW Huang

Professor

Washington University in St. Louis

UNITED STATES
View details