Jeremy Kunz

Assistant Professor

University of Utah Health Huntsman Cancer Institute
Country flagUnited States

Research Interests

ApplyKite TwinLearns as you apply

Make your next move.

Prepare your application

Review drafts before you send them.

Explore related searches

About

Jeremy Kunz is an Assistant Professor at the Huntsman Cancer Institute, University of Utah. His research focuses on high-dose-rate brachytherapy for gynecological malignancies, with recent articles examining image-guided preplanning workflows and dosimetric evaluations of organs at risk. Additionally, he investigates innovative commissioning approaches for brachytherapy applicators and the implementation of diode transmission devices in clinical workflows.

Articles (8)

Year:

2026

Background The adoption of HyperSight CBCT has become widespread due to its rapid CBCT scan acquisition (< 6 s) and superior image quality. Numerous studies have been conducted to evaluate HyperSight CBCT's image quality and the accuracy of treatment planning dose calculations using HyperSight CBCT. Nevertheless, for the main function of CBCT as a tool of image guided radiation therapy (IGRT), one clinically significant question remains unanswered: What is the quantitative correlation between exposure level (mAs) and desired image quality? This study aims to explore the quantitative correlation between exposure level and image quality, providing guidelines for selecting the appropriate CBCT mAs based on imaging objectives and patient size for the optimal IGRT alignment. Purpose To investigate the correlation between HyperSight CBCT (equipped on Halcyon linear accelerator) exposure level and image quality. Methods Nine‐series of 261 sets CBCT scans were acquired using HyperSight on the Halcyon (125 kV, 133‐971 mAs, FOV: 28.2, 36, and 53.8 cm). Three‐series were acquired with the CatPhan 604 alone, three‐series with CatPhan 604 surrounded by a 32 cm custom‐made acrylic annulus, and three series with CatPhan 604 surrounded by a 40 cm custom‐made acrylic annulus. Image quality metrics were analyzed included signal‐to‐noise ratio (SNR), contrast‐to‐noise ratio (CNR), image noise, low‐contrast visibility (LCV), uniformity index (UI), integral non‐uniformity (INU), and modulation transfer function (MTF). The correlation between mAs and image quality was evaluated. Results The SNR and CNR for all material inserts increased with rising mAs for all scans, with a higher amplitude of increase for scans without annuli. The SNR and CNR were higher for scans without annuli. Both image noise and LCV decreased with rising mAs and were higher for scans with annuli. The UI was independent of mAs for scans of CatPhan alone and CatPhan with a small annulus, and was slightly higher for scans without annuli (∼0.1 vs ∼0.2). The INU slightly increased with rising mAs and was higher for scans without annuli. MTF was independent of mAs and with or without annuli. MTF values varied with FOV, with smaller FOV yielding better image sharpness. All parameters were FOV‐dependent except INU, and generally, the larger the FOV, the better the image quality (except spatial resolution). Conclusions HyperSight CBCT acquisition is recommended to be performed with a maximum FOV of 53.8 cm. To meet the Rose criterion, for a 20 cm width object, CBCT should be acquired at ≥154 mAs; for a 32 cm width object, CBCT should be acquired at ≥572.6 mAs to reach a 3σ confidence level; for a 40 cm object, CBCT should be acquired at ≥572.6 mAs to reach a 3σ confidence level for all materials except polystyrene (soft‐tissue).

Year:

2025

Year:

2024

Year:

2023

Year:

2023

Year:

2022

Year:

2021

Year:

2020

Collaborators (4)

Robabeh Rahimi

Associate Professor

University of Maryland

UNITED STATES
View details

Hania Al-Hallaq

Emory University

UNITED STATES
View details

Ryan Price

Associate Professor

University of Utah

UNITED STATES
View details

Firas Mourtada

Professor- Enterprise Medical Physics Director

Thomas Jefferson University

UNITED STATES
View details