Jihyo Hwang
Professor
Research Interests
Explore related searches
Contact this professor
Get a free first email built on one of their papers, ready for you to edit and send yourself.
About
Dr. Jihyo Hwang is a Professor at Kangnam Sacred Heart Hospital in South Korea. His research areas include ultrasound-guided techniques for nerve injuries, robotic-assisted surgeries, and the evaluation of bone mineral density in elderly patients. Recent publications highlight his innovative approaches to treating ulnar neuropathy and hip fractures, as well as his contributions to understanding leg length discrepancies in total hip arthroplasty.
Articles (13)
Year:
2025
Year:
2025
Year:
2025
Year:
2025
Year:
2025
Purpose Robotic arm‐assisted total knee arthroplasty (RTKA) enables adjustment of implant position to achieve the surgeon's preferred alignment. However, the alignment concept that most effectively enhances patient satisfaction remains unclear. This study compares the clinical outcomes of patients who underwent functionally aligned RTKA (FA‐RTKA), mechanically aligned conventional TKA (MA‐CTKA) and mechanically aligned RTKA (MA‐RTKA). Methods A prospectively collected database was retrospectively reviewed for patients who underwent primary TKA for knee osteoarthritis. One hundred and forty‐seven knees were performed with MA‐CTKA, followed by 72 consecutive knees performed with MA‐RTKA, and subsequently, 70 consecutive knees performed with FA‐RTKA were enrolled. After 1:1 propensity score matching of patient demographics, 70 knees were finally included in each group. The extent of additional soft tissue release during surgery was identified, and the Coronal Plane Alignment of the Knee classification was utilised to categorise the alignment. At the 1‐year follow‐up, patient‐reported outcomes, including the pain Visual Analogue Scale, Knee Society Score, Western Ontario and McMaster Universities Arthritis Index and Forgotten Joint Score‐12, were also compared among the groups. Results The FA‐RTKA group showed significantly less additional soft tissue release than the MA‐CTKA and MA‐RTKA groups (15.7%, 38.6% and 35.7%, respectively; p = 0.006). Statistically significant differences in functional scores were observed in the postoperative 1‐year clinical outcomes in favour of the FA‐RTKA group, which had a significantly larger percentage of knees that maintained constitutional alignment and joint line obliquity than those of the other groups. Conclusions Functionally aligned TKA showed superior 1‐year postoperative patient‐reported outcomes compared with those of conventional and robotic arm‐assisted mechanically aligned TKA. Therefore, the advantage of RTKA is maximised when the implant positioning is based on functional alignment. The application of RTKA with mechanical alignment has been proven ineffective in improving the clinical outcomes of patients. Level of Evidence Level III.
Year:
2024
Year:
2023
Year:
2023
Year:
2023
Year:
2021
Year:
2021
Year:
2021
Year:
2020
Collaborators (2)
Joong Il Kim
-
Chanwool Park
Hallym University Kangnam Sacred Heart Hospital
Make your next move.
Prepare your application
Review drafts before you send them.