Jonathan R Polimeni
Has grant
Research Interests
Make your next move.
Prepare your application
Review drafts before you send them.
Explore related searches
Recent Grants
Grant: Close
High-Performance Gradient Coil for 7 Tesla MRI
Open Date: 2023-04-01
Close Date: 2025-03-31
Grant: Close
CRCNS: Computational Modeling of Microvascular Effects in Cortical Laminar fMRI
Open Date: 2021-09-10
Close Date: 2024-05-31
Grant: Close
Precision Mapping the Human Cerebellum for Neuromodulation and Understanding of Brain Disorders
Open Date: 2020-06-01
Close Date: 2023-04-30
Grant: Close
Informing high-resolution functional MRI through modeling microvascular dynamics
Open Date: 2019-08-01
Close Date: 2022-07-31
Grant: Close
Neurovascular dynamics supporting fast and high resolution functional MR imaging
Open Date: 2018-04-01
Close Date: 2021-03-31
Articles (24)
Year:
2026
Year:
2026
Year:
2026
Year:
2026
Functional MRI-based graph theory has provided profound insights into the brain′s functional organization, yet the neuroenergetic meaning of widely used graph-theoretical metrics remains poorly understood. Although resting-state research suggests a positive coupling between network topology and glucose metabolism, it remains unclear whether this relationship reflects a general principle of brain organization or a state-specific phenomenon. Here, we test the neuroenergetic interpretability of nodal graph-theoretical metrics by linking complex network topology to cerebral glucose consumption across diverse brain states. Leveraging simultaneous functional PET-MRI, we directly compare state-dependent fluctuations in glucose consumption and network topology during sensory, cognitive, and arousal conditions. We further assess metabolic-topological couplings in disease through a meta-analysis of resting-state FDG-PET and fMRI studies involving Alzheimer′s disease, Parkinson′s disease, major depressive disorder, and schizophrenia. Our results show that nodal graph-theoretical metrics exhibit state- and network-dependent metabolic associations, with coupling patterns diverging across experimental and disease contexts. Notably, frontoparietal and attentional networks show more conserved metabolic–topological coupling than other large-scale networks across states. These findings underscore a dynamic, complex interplay between metabolic demand and complex network organization, highlighting the need for a nuanced interpretation of the energetic underpinnings of nodal graph-theoretical metrics in health and disease.
Year:
2026
Purpose To suppress inflow effects by saturating the magnetization within slice gaps. Methods Power independent of number of slices (PINS) pulses was designed to saturate the magnetization in all slice gaps at once. The PINS saturation module was played before every excitation. The saturation and excitation profiles were validated in simulation and phantom experiments. To demonstrate the efficacy of the method to suppress inflow, experiments were performed using a flow phantom. As an example use‐case, fMRI experiments with and without PINS inflow saturation were performed at 3 T and 7 T. Results Simulations and phantom experiments showed that the PINS saturation module successfully saturated the magnetization in the slice gaps without degrading the slice profile of the imaging slices. Flow phantom experiments showed that the PINS saturation module suppresses through‐plane inflow better than no‐gap acquisitions. In vivo fMRI experiments demonstrated that the PINS saturation module can be used to modulate the spin‐echo BOLD signal. At 3 T application of PINS pulses to saturate the magnetization in the slice gaps resulted in approximately 25% fewer activated voxels (PINS‐ON vs. PINS‐OFF). Interestingly, at 7 T the activation patterns remained more similar and only approximately 10% fewer activated voxels were detected. The observed difference between 3 and 7 T may be linked to the relative shortening of the blood T 2 . Conclusion Using PINS pulses, inflow effects from slice gaps were effectively and efficiently saturated. The proposed PINS saturation module can be used to further study the contribution of inflow effects in fMRI data.
Year:
2025
Purpose To overcome the major challenges in diffusion MRI (dMRI) acquisition, including limited SNR, distortion/blurring, and susceptibility to motion artifacts. Theory and Methods A novel Romer‐EPTI technique is developed to achieve SNR‐efficient acquisition while providing distortion‐free imaging, minimal spatial blurring, high motion robustness, and simultaneous multi‐TE imaging. It introduces a ROtating‐view Motion‐robust supEr‐Resolution technique (Romer) combined with a distortion/blurring‐free Echo Planar Time‐resolved Imaging (EPTI) readout. Romer enhances SNR through simultaneous multi‐thick‐slice acquisition with rotating‐view encoding, while providing high motion‐robustness via a high‐fidelity, motion‐aware super‐resolution reconstruction. Instead of EPI, the in‐plane encoding is performed using EPTI readout to prevent geometric distortion, T 2 / T 2 *‐blurring, and importantly, dynamic distortions that could introduce additional blurring/artifacts after super‐resolution reconstruction due to combining volumes with inconsistent geometries. This further improves effective spatial resolution and motion robustness. Additional developments include strategies to address slab‐boundary artifacts, achieve minimized TE and optimized readout for additional SNR gain, and increase robustness to strong phase variations at high b ‐values. Results Using Romer‐EPTI, we demonstrated distortion‐free whole‐brain mesoscale in‐vivo dMRI at both 3T (500‐μm isotropic [iso] resolution) and 7T (485‐μm iso resolution) for the first time. Motion experiments demonstrated the technique's motion robustness and its ability to obtain high‐resolution diffusion images in the presence of subject motion. Romer‐EPTI also demonstrated high SNR gain and robustness in high b ‐value ( b = 5000 s/mm 2 ) and time‐dependent dMRI. Conclusion The high SNR efficiency, improved image quality, and motion robustness of Romer‐EPTI make it a highly efficient acquisition for high‐resolution dMRI and microstructure imaging.
Year:
2025
Purpose This study aims to investigate the feasibility of using T 1 ‐weighted fMRI with an iron oxide nanoparticle contrast agent and UTE imaging at 9.4 T to measure functional hyperemia in the mouse visual cortex. The goal is to capture positive signal changes in both the parenchyma and pial surface, and to test whether surface vessels respond during neuronal activation. Method The study involved scanning of nine mice after administration of iron oxide–based superparamagnetic contrast agent via the tail vein. Two functional imaging experiments were conducted: one to investigate the effect of TE on the functional response, and another to characterize the impact of higher resolution on UTE functional contrast. Regions of interest were defined in the parenchyma and pial surface of the visual cortex. Results The administration of the contrast agent produced a bright‐blood signal in the vasculature in structural MRI when using a UTE acquisition. Positive signal changes were observed at the shortest TE (0.164 ms) in voxels sampling both the parenchyma (0.22% ± 0.08%) and pial surface (0.26% ± 0.1%), providing evidence that UTE fMRI experiments can detect changes in both parenchymal and pial vessels. Measurements using longer TEs (≥1 ms) showed negative signal changes, as expected. Higher spatial resolution resulted in increased percent signal change at the pial surface, suggesting reduced partial volume effects. Conclusion The findings demonstrate that T 1 ‐weighted fMRI with UTE imaging and Superparamagnetic Iron Oxide nanoparticles captures positive signal changes across all vascular compartments, providing additional insights into the involvement of surface vessels during functional hyperemia.
Year:
2025
Year:
2025
Year:
2025
Year:
2025
Year:
2025
Year:
2025
Year:
2025
Year:
2025
Year:
2025
Year:
2025
Year:
2025
Year:
2025
Year:
2025
Year:
2025
Year:
2024
Year:
2024
Year:
2024
Collaborators (19)
Anthony David Edwards
King’s College London
Chia-Yin Wu
University of Glasgow
Anna Wang Roe
Professor
Nathan Kline Institute for Psychiatric Research
Joseph Hajnal
King’s College London
Markus Barth
Professor Biomedical Engineering
University of Queensland
Hong-Hsi Lee
Assistant Professor
Massachusetts General Hospital
Nicole R Zürcher
Assistant Professor
-
Jacob Hooker
Massachusetts General Hospital
Ciprian Catana
Professor
Harvard Medical School
Kai-Hsiang Chuang
Associate Professor
University of Queensland
Tomoki Arichi
Professor of Perinatal Neuroscience
King’s College London
Naman Jain
Univeristy Lecturer and Tutor
University of Queensland
Fuyixue Wang
Assistant Professor
Athinoula A. Martinos Center for Biomedical Imaging
Hesheng Liu
Professor
Medical University of South Carolina
Seena Dehkharghani
Professor and Vice Chair
NYU School of Medicine
Shaihan Malik
Reader (Associate Professor)
King’s College London
Martijn Cloos
Associate Professor
University of Queensland
Sharon Giles
King’s College London
Maria Deprez
Reader in Medical Image Analysis
King’s College London
Make your next move.
Prepare your application
Review drafts before you send them.