Joseph Nissan

Head of Department

Tel Aviv University
Country flagIsrael

Research Interests

ApplyKite TwinLearns as you apply

Make your next move.

Prepare your application

Review drafts before you send them.

Explore related searches

Articles (10)

Year:

2026

Year:

2026

Background: In this study, we aimed to compare the effects of conventional and digital impressions on several parameters (inter-implant distance, intra-implant distance, inter-implant axis, and intra-implant axis) of three implants in curved lines and straight lines by using a laboratory scanner (LBS) versus an intra-oral scanner (IOS). Methods: Two 3D models were fabricated using a printer, each model with three internal hex implants analogues at the positions of 15#,16#,17# (straight line) and 12#,13#,14# (curved line). Standard intra-oral scan bodies (ISBs) were used, and the two models were scanned using 7 Series dental wings (LBS, reference model), followed by ten scans with Primescan (digital method). Standard Tessellation Language (STL) files were created. Five polyether impressions were taken from each model (straight and curved), and gypsum type 4 models were poured; each model was scanned five times to create a total of 25 STL files for each group (conventional method). The comparison between all the STL files (conventional and digital) was made by superimposition of the STL files on the STL reference model laboratory file using a 3D analyzing software. A Kolmogorov–Smirnov test was performed, followed by Mann–Whitney tests and Wilcoxon signed-rank tests. (p < 0.05). Results: For the conventional method, the mean errors were significantly higher for the curved line model (12–14) compared to the straight line model (15–17) for most parameters (p < 0.05). For the digital method, the mean errors were significantly higher for the curved-line model (12–14) compared to the straight line model (15–17) in half of the parameters (p < 0.05). Within the curved line model (12–14) and the straight line model (15–17), the mean errors between the conventional method and the digital method were not significant for most variables. Conclusions: The difference between curved lines and straight lines has an impact on the mean error of the conventional method. Both methods are reliable for straight and curved lines in partially dentate situations.

Year:

2024

Year:

2024

Year:

2024

Year:

2024

Year:

2024

Background: The purpose of this in vitro study was to compare the inter-implant distance, inter-implant axis, and intra-implant axis of three implants in a straight line by using a laboratory scanner (LBS) versus an intra-oral scanner (IOS) with two different intra-oral scan bodies (ISBs). Methods: A 3D model was printed with internal hex implant analogs of three implants in positions 15#, 16#, and 17#. Two standard intra-oral scan bodies (ISBs) were used: MIS ISB (two-piece titanium) and Zirkonzhan ISB (two-piece titanium). Both ISBs were scanned using 7 Series dental wings (LBS) and 30 times using Primescan (IOS). For each scan, a stereolithography (STL) file was created and a comparison between all the scans was performed through superimposition of the STL files by using 3D analysis software (PolyWorks® 2020; InnovMetric, Québec, QC, Canada). A Kolmogorov–Smirnov test was performed followed by a Mann–Whitney test (p < 0.05). Results: The change in inter-implant distance for the MIS ISB was significantly lower compared to the ZZ (p < 0.05). The change in intra-implant angle was significantly lower for the ZZ ISB compared to MIS (p < 0.05). The changes in inter-implant angle between the mesial and middle and between the middle and distal were significantly lower for MIS compared to ZZ in contrast to mesial to distal, which was significantly higher (p < 0.05). Conclusions: Both ISBs showed differences in all the parameters between the LBS and the IOS. The geometry of the scan abutment had an impact on the inter-implant distance as the changes in the inter-implant distance were significantly lower for the MIS ISB. The changes in the intra-implant angle were significantly lower for the ZZ ISB. There is a need for further research examining the influence of geometry, material, and scan abutment parts on the trueness.

Year:

2023

Background: Osteoporosis affects bone metabolism and may result in fragility fractures. Medications include bone modulating therapy (BMT), which come with the risk of osteonecrosis of the jaws (ONJ). The literature is contradictory about the impact of osteoporosis and/or BMT on dental implant success and the incidence of ONJ. Purpose: The aim of the present study was to assess the effect of osteoporosis and BMT on early implant failure (EIF) and ONJ incidence (primary outcome parameters) following dental implant placement. Materials and Methods: Retrospective, cohort study based on dental records. Implant-supported prostheses (ISP) were delivered by experienced oral and maxillofacial surgeons and prosthodontists. Inclusion criteria: diagnosis of osteoporosis, delivery of ISP, consecutive individuals, and available data. Confounding variables included—age, gender, smoking status, BMT, bone grafting, and implant length/diameter. Results: There were a total of 72 osteoporosis patients, 46 using and 26 not using BMT. There were a total of 279 inserted implants, 154 in those using and 124 in those not using BMT. Univariate analysis of factors that may affect EIF showed no statistically significant differences between non-osteoporotic, osteoporotic using BMT, and osteoporotic patients not using BMT regarding EIF and ONJ incidence following dental implant delivery. Multivariate model using logistic regression demonstrated one factor associated with increased risk for EIF—bone augmentation. No cases of ONJ were reported up to one year post ISP delivery in any group. Conclusions: Within the limitations of the present study, it can be concluded that installing dental implants in osteoporotic patients, treated or not with BMT, is a safe procedure with EIF comparable to non-osteoporotic patients. The short-term risk for ONJ following dental implant insertion in osteoporotic (even when using BMT) patients is negligible.

Year:

2023

Year:

2023

Collaborators (4)

Liat Chaushu

Tel Aviv University

ISRAEL
View details

Gil Ben-Izhack

-

ISRAEL
View details

Sigalit Blumer

Tel Aviv University

ISRAEL
View details

Asaf Shely

-

ISRAEL
View details