Kaspar F. Bachmann
Research Interests
Explore related searches
Contact this professor
Get a free first email built on one of their papers, ready for you to edit and send yourself.
Articles (11)
Background Thermodilution is unreliable in veno-venous extracorporeal membrane oxygenation (VV-ECMO). Systemic oxygenation depends on recirculation fractions and ratios of extracorporeal membrane oxygenation (ECMO) flow to cardiac output. In a prospective in vitro simulation, this study assessed the diagnostic accuracy of a modified thermodilution technique for recirculation and cardiac output. The hypothesis was that this method provided clinically acceptable precision and accuracy for cardiac output and recirculation. Methods Two ECMO circuits ran in parallel: one representing a VV-ECMO and the second representing native heart, lung, and circulation. Both circuits shared the right atrium. Extra limbs for recirculation and pulmonary shunt were added. This study simulated ECMO flows from 1 to 2.5 l/min and cardiac outputs from 2.5 to 3.5 l/min with recirculation fractions (0 to 80%) and pulmonary shunts. Thermistors in both ECMO limbs and the pulmonary artery measured the temperature changes induced by cold bolus injections into the arterial ECMO limb. Recirculation fractions were calculated from the ratio of the areas under the temperature curve (AUCs) in the ECMO limbs and from partitioning of the bolus volume (flow based). With known partitioning of bolus volumes between ECMO and pulmonary artery, cardiac output was calculated. High-precision ultrasonic flow probes served as reference for Bland–Altman plots and linear mixed-effect models. Results Accuracy and precision for both the recirculation fraction based on AUC (bias, −5.4%; limits of agreement, −18.6 to 7.9%) and flow based (bias, −5.9%; limits of agreement, −18.8 to 7.0%) are clinically acceptable. Calculated cardiac output for all recirculation fractions was accurate but imprecise (RecirculationAUC: bias 0.56 l/min; limits of agreement, −2.27 to 3.4 l/min; and RecirculationFLOW: bias 0.48 l/min; limits of agreement, −2.22 to 3.19 l/min). Recirculation fraction increased bias and decreased precision. Conclusions Adapted thermodilution for VV-ECMO allows simultaneous measurement of recirculation fraction and cardiac output and may help optimize patient management with severe respiratory failure. Editor’s Perspective What We Already Know about This Topic What This Article Tells Us That Is New
Year:
2023
Year:
2023
Year:
2023
Year:
2023
Year:
2023
Year:
2022
This is the first study ever to validate the mean systemic pressure analog (Pmsa) against the reference mean systemic filling pressure (MSFP) determined at full arterio-venous pressure equilibrium. Using a porcine ECMO model with clinically relevant levels of vasoconstriction and volume expansion, we showed that Pmsa accurately estimated absolute and changing values of MSFP, with a poor between-method precision. The within-method precision of Pmsa was excellent.
Year:
2022
Year:
2022
Year:
2022
Year:
2022
Year:
2022
Collaborators (5)
Wendy Davis
University of Western Australia
Luciano Gattinoni
-
David Berger
-
Paul Philipp Heinisch
Ludwig-Maximilians-Universität München
Per Werner Moller
Head of Section Anaesthesiology
-
Make your next move.
Prepare your application
Review drafts before you send them.