Keson Beng Choon Tan

Has grant

Country flagSingapore

Research Interests

ApplyKite TwinLearns as you apply

Make your next move.

Prepare your application

Review drafts before you send them.

Explore related searches

Recent Grants

Grant: Close

Accuracy of Digital Implant Impression Systems

Open Date: 2012-10-01

Close Date: 2015-10-01

Grant: Close

3-D Accuracy of Plastic Transfer Impression Copings for 3 Implant Systems

Open Date: 2009-03-01

Close Date: 2012-02-01

Grant: Close

Accuracy of Fit of Implant-Abutment Systems Interfaces

Open Date: 2007-09-01

Close Date: 2010-08-01

Grant: Close

Development of advanced inverse identification methods for dental implant applications using computational technology

Open Date: 2005-12-01

Close Date: 2008-12-01

Grant: Close

Load Fatigue Performance of Implant-Abutment Combinations

Open Date: 2001-01-01

Close Date: 2004-12-01

Articles (11)

Year:

2026

Year:

2025

Purpose To study the effect of implant angulation on 3D linear and absolute angular distortions of implant analogs in printed resin models and conventional stone casts. Materials and methods Three sectional master models with two implants with total inter‐implant angulations of 0°, 10°, and 20° were fabricated. For each master model, five conventional stone casts (CS) and printed resin models (PM) were fabricated ( n = 5). Test models were made with nonsplinted impression copings and open tray polyether impressions for the CS groups and scan bodies scanned using an intraoral scanner for the PM groups. The physical positions of the implants and implant analogs were measured with a coordinate measuring machine. 3D linear distortion (Δ R ) and absolute angular distortion (Absd θ ) defined the 3D positional accuracy of the analogs in the test models. Univariate ANOVA was used to analyze data followed by post hoc tests (Tukey HSD, α = 0.05). Results Mean Δ R was significantly greater for PM10 (73.5 ± 8.9 µm) and PM20 (65.5 ± 33.3 µm) compared to CS0 (16.8 ± 14.1 µm), CS10 (22.2 ± 13.0 µm), CS20 (15.6 ± 19.9 µm), and PM0 (23.9 ± 16.1 µm). For Absd θ , there were no significant differences between test groups. Conclusions With conventional stone casts, implant angulation had no significant effect on 3D linear and absolute angular distortions. Amongst printed resin models test groups, angulated implants had significantly greater Δ R . Amongst angulated implants test groups, printed resin models had significantly greater Δ R than conventional stone casts. Compared to the master model, all test groups, regardless of inter‐implant angulation, produced greater inter‐analog distances.

Year:

2023

Year:

2022

Year:

2022

Year:

2022

Year:

2021

Year:

2021

Year:

2020

Year:

2020

Year:

2020

Collaborators (2)

Christopher Quek

Senior Lecturer

National University of Singapore (NUS)

SINGAPORE
View details

Ken Tan

Clinical Associate Professor

National Dental Centre of Singapore

SINGAPORE
View details