Keson Beng Choon Tan
Has grant
Research Interests
Make your next move.
Prepare your application
Review drafts before you send them.
Explore related searches
Recent Grants
Grant: Close
Accuracy of Digital Implant Impression Systems
Open Date: 2012-10-01
Close Date: 2015-10-01
Grant: Close
3-D Accuracy of Plastic Transfer Impression Copings for 3 Implant Systems
Open Date: 2009-03-01
Close Date: 2012-02-01
Grant: Close
Accuracy of Fit of Implant-Abutment Systems Interfaces
Open Date: 2007-09-01
Close Date: 2010-08-01
Grant: Close
Development of advanced inverse identification methods for dental implant applications using computational technology
Open Date: 2005-12-01
Close Date: 2008-12-01
Grant: Close
Load Fatigue Performance of Implant-Abutment Combinations
Open Date: 2001-01-01
Close Date: 2004-12-01
Articles (11)
Year:
2026
Year:
2025
Purpose To study the effect of implant angulation on 3D linear and absolute angular distortions of implant analogs in printed resin models and conventional stone casts. Materials and methods Three sectional master models with two implants with total inter‐implant angulations of 0°, 10°, and 20° were fabricated. For each master model, five conventional stone casts (CS) and printed resin models (PM) were fabricated ( n = 5). Test models were made with nonsplinted impression copings and open tray polyether impressions for the CS groups and scan bodies scanned using an intraoral scanner for the PM groups. The physical positions of the implants and implant analogs were measured with a coordinate measuring machine. 3D linear distortion (Δ R ) and absolute angular distortion (Absd θ ) defined the 3D positional accuracy of the analogs in the test models. Univariate ANOVA was used to analyze data followed by post hoc tests (Tukey HSD, α = 0.05). Results Mean Δ R was significantly greater for PM10 (73.5 ± 8.9 µm) and PM20 (65.5 ± 33.3 µm) compared to CS0 (16.8 ± 14.1 µm), CS10 (22.2 ± 13.0 µm), CS20 (15.6 ± 19.9 µm), and PM0 (23.9 ± 16.1 µm). For Absd θ , there were no significant differences between test groups. Conclusions With conventional stone casts, implant angulation had no significant effect on 3D linear and absolute angular distortions. Amongst printed resin models test groups, angulated implants had significantly greater Δ R . Amongst angulated implants test groups, printed resin models had significantly greater Δ R than conventional stone casts. Compared to the master model, all test groups, regardless of inter‐implant angulation, produced greater inter‐analog distances.
Year:
2023
Year:
2022
Year:
2022
Year:
2022
Year:
2021
Year:
2021
Year:
2020
Year:
2020
Year:
2020
Collaborators (2)
Christopher Quek
Senior Lecturer
National University of Singapore (NUS)
Ken Tan
Clinical Associate Professor
National Dental Centre of Singapore
Make your next move.
Prepare your application
Review drafts before you send them.