Kishore Rajendran
Associate Professor
Research Interests
Make your next move.
Prepare your application
Review drafts before you send them.
Explore related searches
Articles (15)
Year:
2026
Objectives Determine differences in quantitative stenosis severity measurements for ultra-high-resolution (UHR) photon-counting detector (PCD) coronary CT angiography (cCTA) relative to energy-integrating detector (EID) cCTA in a large patient cohort. Methods Adult participants seen between November 2022 and March 2023 underwent a clinical dual-source EID-CT cCTA and a research dual-source PCD-CT cCTA on the same day. Percent diameter stenosis (PDS) was measured, and stenosis severity was assigned based on the PDS of the most severe lesion per patient to determine a coronary artery disease reporting and data system (CAD-RADS) score. Agreement between EID-CT and PCD-CT for PDS and CAD-RADS was determined. Results A total of 112 participants were enrolled, yielding 82 subjects with at least 1 stenosis at PCD-CT (mean age, 68.0 ± 10.8 years; 69.5% [57/82] males). A total of 177 paired stenoses were quantified. The percent decrease in mean PDS from PCD-CT (24.3%) to EID-CT (29.4%) was 17.3% (median difference in PDS: −5.0%, 95% CI: −5.7% to −4.0%). The assigned CAD-RADS score changed in 31/82 subjects. In 11/31 subjects, the most severe stenosis was missed at EID-CT due to partial volume averaging of a small calcification, yet PCD clearly identified stenosis at those locations. In 20/31 subjects, the CAD-RADS score decreased at PCD-CT due to the decreased calcium blooming resulting from the improved spatial resolution. Conclusions UHR PCD cCTA decreases quantitative measures of stenosis severity when a stenosis is identified at EID, leading to decreases in CAD-RADS assignments. Advances in knowledge With its improved spatial resolution, PCD-CT identifies stenoses missed on EID-CT.
Year:
2026
Objectives: The aims of the study were to evaluate the spectral performance of an investigational dual-source (DS) scan mode using a tin (Sn) filter on the B-subsystem of a clinical photon-counting detector (PCD) CT system and to demonstrate improved material decomposition performance using clinical examples of bone imaging tasks. Materials and Methods: Calcium inserts (Ca 100, 200 and 300 mg/cc) were placed in water phantoms (30-, 40-, and 50-cm lateral diameter) and scanned on clinical PCD-CT (NAEOTOM Alpha, Siemens) using DS spectral scan mode (QuantumPeak). Two tube potential configurations (70/Sn150 kV and 90/Sn150 kV) were used to scan the phantoms (11 mGy to 41 mGy volume CT dose index). The phantoms were also scanned using the single-source (SS) PCD-CT scan mode at 120 kV and 140 kV tube potential, and on a DS energy-integrating detector (EID) CT (SOMATOM Force, Siemens) for quantitative comparison. CT images (from SS-PCD-CT, DS-PCD-CT, and DS-EID-CT) were reconstructed using a quantitative kernel (Qr40) at a 2-mm section thickness using iterative reconstruction strength 1. Spectral separation was quantified using the dual-energy ratio (DER) of Ca inserts and using mean absolute percent error (MAPE) of Ca mass density obtained from Ca/water material decomposition. To demonstrate clinical feasibility, 4 patients were scanned using DS-PCD-CT under an institutional review board-approved study. Bone edema maps were reconstructed from DS-PCD-CT and compared with the corresponding clinical imaging exam of the same patients (MRI or DS-EID-CT). Results: DS-PCD-CT at 70/Sn150 kV for Ca 100 mg/cc showed the highest mean DER (2.49 and 2.56 at 30 and 40 cm, respectively) among all scan configurations. For the 50-cm phantom at Ca 100 mg/cc, DS-PCD-CT at 90/Sn150 kV showed highest mean DER (1.88), followed by DS-EID-CT at 90/Sn 150 kV (1.87) and SS-PCD-CT at 140 kV (1.78). The MAPE values for DS-PCD-CT were consistently lower across all phantom sizes (MAPE max. of 1.44%) compared to SS-PCD-CT (MAPE max. 3.97%) and DS-EID-CT (MAPE max. 3.68%). Qualitatively, patient images illustrated bone edema depiction on DS-PCD-CT comparable to clinical MR images, and more precise edema depiction compared to DS-EID-CT images at the site of fractures and intramedullary lesions, and with fewer artifacts. Conclusions: DS-PCD-CT showed superior spectral performance for calcium imaging tasks compared to SS-PCD-CT and DS-EID-CT.
Year:
2026
Quantitative computed tomography (CT) enables the measurement of biophysical processes characterized by morphology, composition, flow, and/or motion to aid in clinical diagnosis and intervention. Since its initial application for determining bone mineral density for skeletal fragility assessment, quantitative CT has continued to evolve alongside CT’s technological advancements. A key challenge facing quantitative CT is the lack of standardization pertinent to image acquisition, reconstruction, and image analysis. With the introduction of spectral CT involving dual-energy approaches and photon-counting detectors (PCD), we are now able to obtain detailed information regarding mass densities of endogenous and exogeneous materials. Furthermore, energy-resolved CT yields spectral image types (eg, virtual monoenergetic image) that are, in principle, independent of tube potential and patient size. This paves the way for workflow standardization and helps improve the consistency and reproducibility of CT-derived measurements. In this article, we review clinical applications of quantitative CT, discuss key challenges associated with quantitative CT and its adoption into routine practice, and outline the unique benefits ushered by new CT technologies such as PCD-CT towards improving quantitative imaging.
Year:
2025
Photon-counting detector CT (PCD-CT) represents a significant advancement in medical imaging, particularly for musculoskeletal (MSK) applications. Its primary innovation lies in enhanced spatial resolution, which facilitates improved detection of small anatomical structures such as trabecular bone, osteophytes, and subchondral cysts. PCD-CT enables high-quality imaging with reduced radiation doses, making it especially beneficial for populations requiring frequent imaging, such as paediatric patients and individuals with multiple myeloma. Additionally, PCD-CT supports advanced applications like bone quality assessment, which correlates well with gold-standard tests, and can aid in diagnosing osteoporosis and assessing fracture risk. Techniques such as spectral shaping and virtual monoenergetic imaging further optimize the technology, minimizing artefacts and enhancing material decomposition. These capabilities extend to conditions like gout and haematologic malignancies, offering improved detection and assessment. The integration of artificial intelligence could enhance PCD-CT’s performance by reducing image noise and improving quantitative assessments. Ultimately, PCD-CT’s superior resolution, reduced dose protocols, and multi-energy imaging capabilities will likely have a transformative impact on MSK imaging, improving diagnostic accuracy, patient care, and clinical outcomes.
Year:
2025
Objective. To assess the accuracy and stability of areal bone-mineral-density (aBMD) measurements from multi-energy CT localizer radiographs acquired using photon-counting detector (PCD) CT. Approach. A European Spine Phantom (ESP) with hydroxyapatite (HA 0.5, 1.0 and 1.5 g cm −2 ) was scanned using clinical PCD-CT and a dual-energy x-ray absorptiometry (DXA) to compare aBMD values. To assess aBMD stability and reproducibility, PCD-localizers were acquired twice a day for one week, and once per week for five weeks. Multiple ESP anteroposterior thicknesses (18, 26, 34, and 40 cm) were achieved using a synthetic gel layer and scanned across eight tube current values for both 120 kV (15–120 mA) and 140 kV (10–80 mA). One-way analysis of variance was performed for statistical significance ( p < 0.05 considered significant). Quantitative HA and water maps were reconstructed using a prototype material-decomposition software, and aBMD was calculated after background correction. In vivo performance of PCD-based aBMD was illustrated using a patient scan acquired at 140 kV and 40 mA, and lumbar aBMD values were compared with DXA. Main results. The ESP aBMD values from PCD-localizers demonstrated excellent day-to-day stability with a coefficient-of-variation ranging from 0.42% to 0.53%, with mean absolute percentage errors (MAPE) of less than 5% for all three vertebral bodies. The coefficient-of-variation for weekly scans ranged from 0.17% to 0.60%, again with MAPE below 5% for all three vertebral bodies. Across phantom sizes and tube currents, the MAPE values varied ranging from 1.84% to 13.78% for 120 kV, and 1.38%–9.11% for 140 kV. No significant difference was found between different tube currents. For the standard phantom size, DXA showed 11.21% MAPE whereas PCD-CT showed 3.04% MAPE. For the patient scan, deviation between PCD-based aBMD values and those obtained from DXA ranged from 0.07% to 9.82% for different lumbar vertebra. Significance. This study highlights the accuracy and stability of PCD-CT localizers for measuring aBMD. We demonstrated aBMD accuracy across different sizes and showed that higher radiation doses did not inherently increase aBMD accuracy.
Year:
2024
Year:
2024
Objective . Photon-counting detector (PCD) CT enables routine virtual-monoenergetic image (VMI) reconstruction. We evaluated the performance of an automatic VMI energy level (keV) selection tool on a clinical PCD-CT system in comparison to an automatic tube potential (kV) selection tool from an energy-integrating-detector (EID) CT system from the same manufacturer. Approach. Four torso-shaped phantoms (20–50 cm width) containing iodine (2, 5, and 10 mg cc −1 ) and calcium (100 mg cc −1 ) were scanned on PCD-CT and EID-CT. Dose optimization techniques, task-based VMI energy level and tube-potential selection on PCD-CT (CARE keV) and task-based tube potential selection on EID-CT (CARE kV), were enabled. CT numbers, image noise, and dose-normalized contrast-to-noise ratio (CNR d ) were compared. Main results . PCD-CT produced task-specific VMIs at 70, 65, 60, and 55 keV for non-contrast, bone, soft tissue with contrast, and vascular settings, respectively. A 120 kV tube potential was automatically selected on PCD-CT for all scans. In comparison, EID-CT used x-ray tube potentials from 80 to 150 kV based on imaging task and phantom size. PCD-CT achieved consistent dose reduction at 9%, 21% and 39% for bone, soft tissue with contrast, and vascular tasks relative to the non-contrast task, independent of phantom size. On EID-CT, dose reduction factor for contrast tasks relative to the non-contrast task ranged from a 65% decrease (vascular task, 70 kV, 20 cm phantom) to a 21% increase (soft tissue with contrast task, 150 kV, 50 cm phantom) due to size-specific tube potential adaptation. PCD-CT CNR d was equivalent to or higher than those of EID-CT for all tasks and phantom sizes, except for the vascular task with 20 cm phantom, where 70 kV EID-CT CNR d outperformed 55 keV PCD-CT images. Significance . PCD-CT produced more consistent CT numbers compared to EID-CT due to standardized VMI output, which greatly benefits standardization efforts and facilitates radiation dose reduction.
Year:
2024
Year:
2023
Year:
2023
Year:
2023
Year:
2023
Year:
2023
Year:
2023
Year:
2023
Collaborators (3)
Fang-Shu Ou
Mayo Clinic
Ronald Booij
Erasmus University Rotterdam
Kevin Treb
Faculty, Assistant Professor
University of Minnesota Twin Cities
Make your next move.
Prepare your application
Review drafts before you send them.