Kumiko Oguma
Research Interests
Make your next move.
Prepare your application
Review drafts before you send them.
Explore related searches
Articles (3)
Objectives We aimed to investigate the quality of platelets after storage following irradiation with ultraviolet C (UVC) light‐emitting diodes (LED). Background Controlling transfusion‐related infections, particularly bacterial contamination of platelet concentrates (PCs), is urgently required. UVC‐LEDs have attracted considerable attention as potential solutions to this problem. Methods PCs (5.5 mL) were irradiated with 265 nm UVC‐LED for up to 60 min and then stored at 22°C with shaking for 3 days. PC quality parameters, such as platelet count, biochemical profiles, including electrolytes and metabolism, activation markers and platelet aggregability, were analysed before and after storage. Prior to the storage study, to validate the appropriateness of the UVC‐LED dose used, the PCs were inoculated with Staphylococcus aureus or Bacillus cereus , and their colony‐forming ability was evaluated after irradiation with the same dose of UVC‐LED. Results We confirmed that S. aureus and B. cereus colonies decreased with the irradiation dose (by 1.7 log and 1.2 log at 38.7 and 40.4 mJ cm −2 , respectively). Platelet count decreased immediately after 60‐minute irradiation to 32.5 mJ cm −2 , reaching approximately 80% of the level in the control without irradiation, but no further decrease was recorded after storage. The biochemical profiles and activation markers showed little alterations. Conclusion These results indicate that UVC‐irradiated platelets maintain sufficient quality for practical use even after storage. Although this was a bench‐scale study, our findings suggest that irradiation of PCs with 265 nm UVC‐LED may enhance the safety of blood transfusions while preserving their efficacy.
Year:
2025
Waterborne outbreaks caused by protozoan, bacterial, and viral pathogens continue to pose serious public health threats. However, comprehensive monitoring of all three major pathogen types remains uncommon, primarily due to the technical difficulty of simultaneously concentrating and characterizing these diverse microorganisms from a single water sample. Here, we evaluated a membrane adsorption followed by bead-beating-based direct nucleic acid extraction for its sensitivity in detecting waterborne pathogens. We further applied the optimized protocol to river water samples. Our results demonstrated that the use of magnesium chloride in combination with a mixed cellulose ester membrane filter (pore size: 0.8 μm) achieved the highest concentration efficiency for Cryptosporidium parvum , Legionella pneumophila , and murine norovirus (MNV), outperforming other methods utilizing the membrane with alternative pore sizes or membrane with another material (i.e., nylon). Furthermore, targeting rRNA of C. parvum instead of rDNA, or incorporating a preamplification step for the L. pneumophila mip gene and MNV, significantly improved the sensitivity. Notably, the 50% limit of detection for C. parvum using our method was comparable to that of traditional immunofluorescent antibody testing. Application of this method to river water further revealed a higher abundance of Bacteroides rRNA markers compared to their corresponding rDNA, underscoring the potential of rRNA-based targets for more sensitive bacterial detection. Importantly, when the target is genomic DNA or RNA, preamplification enables the use of a larger nucleic acids input volume, thereby enhancing sensitivity without introducing measurement bias. Overall, the combination of membrane adsorption and bead-beating-based direct nucleic acid extraction offers a sensitive, all-in-one approach for simultaneous detection of protozoa, bacteria, and viruses in environmental water. This method serves as an effective ‘screening’ tool for the presence of the three major types of waterborne microorganisms. Graphical Abstract
Year:
2025
In UV disinfection of water, the fluence of UV required to inactivate a target microorganism is determined based on the procedures developed for conventional mercury‐based UV lamps with collimation. In this regard, a simple and practical method with a mathematical model and radiometry is proposed for determining the fluence rate with UV light‐emitting diodes (UV‐LEDs). This method was applied to a bench‐scale UV‐LED setup and validated by comparing the calculations with the measurements using either a spectroradiometer or a chemical actinometer. The results showed high accordance with spectroradiometer outputs with a linear regression equation y = 0.997 x ( x : model calculation, y : spectroradiometer output, r 2 = 0.999, P < 0.001 for n = 20) in an experiment varying the distance between the measurement points and the UV‐LEDs. Meanwhile, the proposed method and chemical actinometry exhibited 98% concordance. Furthermore, this method was applied to determine the fluence‐response profiles of Pseudomonas aeruginosa , and the results demonstrated that the proposed method was appropriate at two different distances between the UV‐LEDs and the solutions. To conclude, the proposed method can determine the fluence in a UV‐LED bench‐scale setup in a simple and practical way, which would potentially promote the research and development of water treatment using UV‐LEDs.
Year:
2022
Collaborators (5)
Shotaro Torii
Senior Assistant Professor (Tenured)
University of Tokyo
Masaaki Kitajima
Hokkaido University
Eiji Haramoto
Professor
University of Yamanashi
Ryota Gomi
Project Associate Professor
University of Tokyo
Hiroyuki Katayama
Associate Professor
University of Tokyo
Make your next move.
Prepare your application
Review drafts before you send them.