Laura M. Schreiber
Has grant
Research Interests
Explore related searches
Contact this professor
Get a free first email built on one of their papers, ready for you to edit and send yourself.
Recent Grants
Grant: Close
MAGNET4Cardiac7T - Modelling of electromagnetic fields using neuronal networks for 7T MRI of the heart
Open Date: 2022-12-01
Close Date: 2025-05-01
Grant: Close
7T-Ultrahochfeld-Magnetresonanz-Bildgebung von myeloischen Zellen in Schweinen als Basis für eine translationale Plattform für kardiale Immuntherapie
Open Date: 2022-01-01
Close Date: 2025-01-01
Grant: Close
Serviceprojekt für Tiermodelle und Bildgebung (PS1)
Open Date: 2022-01-01
Close Date: 2025-01-01
Grant: Close
Klinische Herzbildgebung am MAGNETOM Terra
Open Date: 2021-01-01
Close Date: 2024-01-01
Grant: Close
German Ultrahigh Field Imaging (GUFI)
Open Date: 2017-01-01
Close Date: 2021-12-31
Articles (11)
Year:
2024
Year:
2023
Year:
2023
Year:
2023
A complementary safety assessment of the specific absorption rate (SAR) of the electromagnetic energy was performed in a prototype 8Tx/16Rx RF array for cardiac magnetic resonance imaging (MRI) at 7 T. The study aimed to address two critical aspects of 7‐T SAR safety not always explicitly examined by coil vendors: (i) the influence of an RF‐array position on a peak SAR value, and (ii) the risk of exceeding the permitted maximal SAR in the tissue surrounding conductive passive implants. The full‐wave 3D electromagnetic simulations for the thorax with shifted array position and the whole‐body volume in the presence of a dental retainer, an intrauterine contraceptive device (IUD), and a hip joint implant, were performed for two human voxel models. The effect of the array displacement on the SAR was simulated for seven array locations on the thorax shifted from the central position in different directions on 50 mm. The peak SAR values for both models were analyzed for the three phase‐only transmit vectors optimized for B 1 + homogeneity and transmit efficiency. Peak SAR values due to the shifts of the array position increase up to ≈50%. The worst‐case peak SAR value for a dental retainer was found to be in the range of 10% of the maximal SAR in the tissue within the array's borders. For the IUD and artificial hip joint implants the effect was found to be negligible (peak SAR < 1% of the SAR within array borders). In addition to simulations for cardiac MRI, we performed a preliminary B 1 + shimming and SAR‐safety analysis for the same RF‐array at various positions lower on the body trunk to assess a potential application in imaging abdominopelvic organs (prostate, kidney, and liver). The most promising target for an ad hoc alternative application of the array was found to be the prostate.
Year:
2023
Year:
2023
Year:
2023
Year:
2023
Year:
2022
Year:
2022
Year:
2022
Collaborators (8)
Michael Bock
Professor for Experimental Radiology, Vice Chair of Department
University Medical Center Freiburg
Sachin Jambawalikar
Chief of Medical Physics/ Assist. Professor of Radiology
Columbia University
Jelena Janjic
Associate Professor of Pharmaceutics
-
Anna Frey
University Hospital Würzburg
Christoph Juchem
Associate Professor
Columbia University
Andreas Max Weng
-
Ruud B van Heeswijk
Senior Lecturer
Lausanne University Hospital (CHUV)
Yun Shang
Weill Cornell Medicine
Make your next move.
Prepare your application
Review drafts before you send them.