Laura M. Schreiber

Has grant

Country flagGermany

Research Interests

Explore related searches

Contact this professor

Get a free first email built on one of their papers, ready for you to edit and send yourself.

Recent Grants

Grant: Close

MAGNET4Cardiac7T - Modelling of electromagnetic fields using neuronal networks for 7T MRI of the heart

Open Date: 2022-12-01

Close Date: 2025-05-01

Grant: Close

7T-Ultrahochfeld-Magnetresonanz-Bildgebung von myeloischen Zellen in Schweinen als Basis für eine translationale Plattform für kardiale Immuntherapie

Open Date: 2022-01-01

Close Date: 2025-01-01

Grant: Close

Serviceprojekt für Tiermodelle und Bildgebung (PS1)

Open Date: 2022-01-01

Close Date: 2025-01-01

Grant: Close

Klinische Herzbildgebung am MAGNETOM Terra

Open Date: 2021-01-01

Close Date: 2024-01-01

Grant: Close

German Ultrahigh Field Imaging (GUFI)

Open Date: 2017-01-01

Close Date: 2021-12-31

Articles (11)

Year:

2024

Year:

2023

Year:

2023

Year:

2023

A complementary safety assessment of the specific absorption rate (SAR) of the electromagnetic energy was performed in a prototype 8Tx/16Rx RF array for cardiac magnetic resonance imaging (MRI) at 7 T. The study aimed to address two critical aspects of 7‐T SAR safety not always explicitly examined by coil vendors: (i) the influence of an RF‐array position on a peak SAR value, and (ii) the risk of exceeding the permitted maximal SAR in the tissue surrounding conductive passive implants. The full‐wave 3D electromagnetic simulations for the thorax with shifted array position and the whole‐body volume in the presence of a dental retainer, an intrauterine contraceptive device (IUD), and a hip joint implant, were performed for two human voxel models. The effect of the array displacement on the SAR was simulated for seven array locations on the thorax shifted from the central position in different directions on 50 mm. The peak SAR values for both models were analyzed for the three phase‐only transmit vectors optimized for B 1 + homogeneity and transmit efficiency. Peak SAR values due to the shifts of the array position increase up to ≈50%. The worst‐case peak SAR value for a dental retainer was found to be in the range of 10% of the maximal SAR in the tissue within the array's borders. For the IUD and artificial hip joint implants the effect was found to be negligible (peak SAR < 1% of the SAR within array borders). In addition to simulations for cardiac MRI, we performed a preliminary B 1 + shimming and SAR‐safety analysis for the same RF‐array at various positions lower on the body trunk to assess a potential application in imaging abdominopelvic organs (prostate, kidney, and liver). The most promising target for an ad hoc alternative application of the array was found to be the prostate.

Year:

2023

Year:

2023

Year:

2023

Year:

2023

Year:

2022

Year:

2022

Year:

2022

Collaborators (8)

Michael Bock

Professor for Experimental Radiology, Vice Chair of Department

University Medical Center Freiburg

GERMANY
View details

Sachin Jambawalikar

Chief of Medical Physics/ Assist. Professor of Radiology

Columbia University

UNITED STATES
View details

Jelena Janjic

Associate Professor of Pharmaceutics

-

UNITED STATES
View details

Anna Frey

University Hospital Würzburg

GERMANY
View details

Christoph Juchem

Associate Professor

Columbia University

UNITED STATES
View details

Andreas Max Weng

-

GERMANY
View details

Ruud B van Heeswijk

Senior Lecturer

Lausanne University Hospital (CHUV)

SWITZERLAND
View details

Yun Shang

Weill Cornell Medicine

UNITED STATES
View details
ApplyKite TwinLearns as you apply

Make your next move.

Prepare your application

Review drafts before you send them.