Laurent Le Guillou

Associate Professor / Maître de Conférences

Sorbonne Université
Country flagFrance

Research Interests

Explore related searches

Contact this professor

Get a free first email built on one of their papers, ready for you to edit and send yourself.

About

Dr. Laurent Le Guillou is an Associate Professor at Sorbonne Université in France. His research areas encompass atmospheric science and instrumentation, focusing on the calibration of infrared thermal cameras and the characterization of atmospheric transmission. Recent publications include studies on slitless spectrophotometry and the design of collimated beam projectors for telescope transmission measurement.

Articles (3)

Type Ia supernovae are the most direct cosmological probe to study dark energy in the recent Universe, for which the photometric calibration of astronomical instruments remains one major source of systematic uncertainties. To address this, recent advancements introduce collimated beam projectors (CBPs), aiming to enhance calibration by precisely measuring a telescope’s throughput as a function of wavelength. This work describes the performance of a prototype portable CBP. The experimental set-up consists of a broad-band Xenon light source replacing a more customary but much more demanding high-power laser source, coupled with a monochromator emitting light inside an integrating sphere monitored with a photodiode and a spectrograph. Light is injected at the focus of the CBP telescope projecting a collimated beam onto a solar cell whose quantum efficiency has been obtained by comparison with a NIST-calibrated photodiode. The throughput and signal-to-noise ratio achieved by comparing the photocurrent signal in the CBP photodiode with the one in the solar cell are computed. We prove that the prototype, in its current state of development, is capable of achieving 1.2 per cent and 2.3 per cent precision on the integrated g and r bands of the Zwicky Transient Facility photometric filter system, respectively, in a reasonable amount of integration time. Central wavelength determination accuracy is kept below ∼0.91 and ∼0.58 nm for g and r bands, respectively. The expected photometric uncertainty caused by filter throughput measurement is approximately 5 mmag on the zero-point magnitude. Several straightforward improvement paths are discussed to upgrade the current set-up.

Year:

2024

Year:

2024

Year:

2024

Collaborators (3)

Yannick Copin

Associate professor (with habilitation)

Institut de Physique des 2 Infinis de Lyon

FRANCE
View details

Bertrand Plez

Professor

University of Montpellier

FRANCE
View details

C W Stubbs

Harvard University

UNITED STATES
View details
ApplyKite TwinLearns as you apply

Make your next move.

Prepare your application

Review drafts before you send them.