Lena Nohava

Has grant

Research Associate (permanent)

Medical University of Vienna
Country flagAustria

Research Interests

ApplyKite TwinLearns as you apply

Make your next move.

Prepare your application

Review drafts before you send them.

Explore related searches

Recent Grants

Grant: Close

Breast MRI with a flexible radio frequency coil vest: in vivo technical and clinical performance evaluation

Open Date: 2022-09-01

Close Date: 2024-09-01

Articles (12)

Year:

2025

Year:

2025

Year:

2025

Year:

2025

Supine breast MRI offers easier comparison with other screening methods than the prone MRI, but is often impaired by respiratory artifacts. This study aims to identify a suitable acceleration technique for motion-corrected supine breast MRI with a dedicated wearable coil (BraCoil), and to assess the quality of the resulting images. This prospective, single-center study included ten healthy female volunteers. Supine breast MRI was acquired using the BraCoil equipped with seven accelerometers. The acquisition protocol included unenhanced T1- and T2-weighted sequences; 2-, 3-, and 4-fold acceleration, as well as “elliptical scanning”, were tested for T1-weighted images. Image reconstruction was performed using two methods: the manufacturer’s standard algorithm and an advanced nonrigid motion correction algorithm. The images were compared to each other and to conventional prone MRI via radiological scoring. Additionally, comparisons were made with supine breast MRI obtained using a multi-purpose torso coil reported in previous studies. This study showed that using 2-fold acceleration was optimal for motion-corrected supine breast MRI using the BraCoil. It also demonstrated that enabling the “elliptical scanning” would shorten the measurement time by 33% without compromising image quality. Finally, for the data acquired, the BraCoil provides superior motion-corrected image quality compared to the torso coil. Key Points BraCoil image quality outperforms the body coil for both uncorrected and motion-corrected images in supine acquisition for T1w and T2w sequences. Enabling the “elliptical scanning” in T1-weighted sequences does not impair image quality while shortening the measurement time by 33% (compared to the same sequence without enabling this option). A 2-fold acceleration for the T1-weighted sequence provides sufficient scan time reduction, whereas higher acceleration would lead to even shorter scan time at the cost of significantly lower image quality. Graphical Abstract

Year:

2025

Year:

2025

Transcranial magnetic stimulation (TMS) applied to a left dorsolateral prefrontal cortex (DLPFC) area with a specific connectivity profile to the subgenual anterior cingulate cortex (sgACC) has emerged as a highly effective non-invasive treatment option for depression. However, antidepressant outcomes demonstrate significant variability among therapy plans and individuals. One overlooked contributing factor is the individual brain state at the time of treatment. In this study we used interleaved TMS-fMRI to investigate the influence of brain state on acute TMS effects, both locally and remotely. TMS was performed during rest and during different phases of cognitive task processing. Twenty healthy participants were included in this study. In the first session, imaging data for TMS targeting were acquired, allowing for identification of individualized targets in the left DLPFC based on highest anti-correlation with the sgACC. The second session involved chronometric interleaved TMS-fMRI measurements, with 10 Hz triplets of TMS administered during rest and at distinct timings during an N-back task. Consistent with prior findings, interleaved TMS-fMRI revealed significant BOLD activation changes in the targeted network. The precise timing of TMS relative to the cognitive states during the task demonstrated distinct BOLD response in clinically relevant brain regions, including the sgACC. Employing a standardized timing approach for TMS using a task revealed more consistent modulation of the sgACC at the group level compared to stimulation during rest. In conclusion, our findings strongly suggest that acute local and remote effects of TMS are influenced by brain state during stimulation. This study establishes a basis for considering brain state as a significant factor in designing treatment protocols, possibly improving TMS treatment outcomes.

Year:

2024

Investigations of human brain disorders are frequently conducted in rodent models using magnetic resonance imaging. Due to the small specimen size and the increase in signal-to-noise ratio with the static magnetic field strength, dedicated small-bore animal scanners can be used to acquire high-resolution data. Ultra-high-field (≥7 T) whole-body human scanners are increasingly available, and they can also be used for animal investigations. Dedicated sensors, in this case, radiofrequency coils, are required to achieve sufficient sensitivity for the high spatial resolution needed for imaging small anatomical structures. In this work, a four-channel transceiver coil array for rat brain imaging at 7 T is presented, which can be adjusted for use on a wide range of differently sized rats, from infants to large adults. Three suitable array designs (with two to four elements covering the whole rat brain) were compared using full-wave 3D electromagnetic simulation. An optimized static B1+ shim was derived to maximize B1+ in the rat brain for both small and big rats. The design, together with a 3D-printed adjustable coil housing, was tested and validated in ex vivo rat bench and MRI measurements.

Year:

2024

Magnetic Resonance Imaging (MRI) is a major medical imaging modality, which is non-invasive and provides unique soft tissue contrast without ionizing radiation. The successful completion of MRI exams critically depends on patient compliance, and, thus patient comfort. The design, appearance and usability of local MRI radiofrequency (RF) coils potentially influences the patients’ perception of the exam. However, systematic investigations and empirical evidence for these aspects are missing. A questionnaire specifically evaluating the impact of RF coils on patient comfort in MRI would be a valuable addition to clinical studies comparing the performance of novel flexible RF coils with standard rigid coils. This paper describes the development of such a questionnaire in the scope of a citizen science (CS) initiative conducted with a group of students at the upper secondary school level. In this work, the CS initiative is presented in the format of a case report and its impact on scientific projects and the students’ education is outlined. The resulting questionnaire is made available in German and English so as to be directly applicable by researchers working on the clinical evaluation of novel RF coils or the comfort evaluation of specific hardware setups in general.

Year:

2024

Year:

2023

Year:

2023

Year:

2023

Collaborators (9)

Freddy Odille

Université de Lorraine

FRANCE
View details

Christian Windischberger

Universität Wien

AUSTRIA
View details

Michael Woletz

Medical University of Vienna

AUSTRIA
View details

Roberta Frass-Kriegl

Medical University of Vienna

AUSTRIA
View details

jacques Felblinger

Faculty member / Enseignant-chercheur / Enseignante-chercheuse

Université de Lorraine

FRANCE
View details

Anna-Lisa Schuler

Max Planck Institute for Human Cognitive and Brain Sciences

GERMANY
View details

Elmar Laistler

Associate Professor

Medical University of Vienna

AUSTRIA
View details

Renata Georgia Raidou

Assistant Professor (Tenure Track)

TU Wien

AUSTRIA
View details

Karyna Isaieva

Support staff / Personnel d'appui

Université de Lorraine

FRANCE
View details