Luis Gimeno
Research Interests
Explore related searches
Contact this professor
Get a free first email built on one of their papers, ready for you to edit and send yourself.
Articles (18)
Radiosonde measurements of relative humidity (RH) are the main source of uncertainty in precipitable water vapour (PWV) calculation from pressure, temperature, and RH/dewpoint (PTU) data. This paper presents a formula expressing PWV in terms of pressure and temperature as functions of geopotential height (GPH), thereby allowing the PWV to be determined: (1) without any moisture‐related calculations other than those involved in measuring GPH (in radiosondes with a pressor sensor) or pressure (otherwise); (2) without relying on humidity measurements by using Global Positioning System (GPS)‐based GPH according to the gravity field, provided that pressure is directly measured. The numerical instability associated with random data errors or deviations from hydrostatic equilibrium makes the second approach unfeasible on short time scales, revealing discrepancies between the PTU‐ and GPS‐based GPHs; however, the estimation of long‐term average PWV above a location is not hindered. The estimation of PWV without humidity data was tested using high‐resolution data from 62 upper‐air stations operated by the NOAA National Weather Service. The seasonal mean {DJF, MAM, JJA, SON} PWV from the surface to 300 hPa calculated from PT and GPS data over the period 2016–2018, after rejecting individual estimates inconsistent with the 0%–100% RH range, showed a mean bias error of {−0.1, +0.1, −1.4, −0.9} kg·m −2 relative to the PTU‐based values across the stations, and a RMSE ranging from 2.4 (DJF) to 3.2 (JJA) kg·m −2 . By restricting the analysis to observations with above‐average matching between the PTU‐ and GPS‐based GPH, the bias magnitude and RMSE reduced respectively to less than 0.5 and 1 kg·m −2 in all seasons. The results indicate that evaluating the long‐term agreement between the two PWV calculation methods at different sites could be useful in detecting systematic observation errors in GPS radiosonde systems using a pressure sensor.
Year:
2024
Year:
2024
Year:
2024
Year:
2024
Year:
2024
Year:
2023
Year:
2023
Year:
2023
Year:
2023
Year:
2023
Year:
2023
Year:
2023
Year:
2023
Year:
2023
Year:
2023
Year:
2022
Year:
2022
Year:
2022
Collaborators (9)
Ana M. Vicedo-Cabrera
University of Bern
Rogert Sorí Gómez
Universidade de Vigo
Diego Miralles
Professor at Ghent University
Ghent University
Raquel Nieto
Assistant Professor
Universidade de Vigo
Jorge Eiras-Barca
Assistant Professor
Defense University Center at the Spanish Naval Academy
Brunet-India Manola
Professor of Physical Geography
Universitat Rovira i Virgili
Milica Stojanovic
Universidade de Vigo
Margarida Liberato
Professora Associada
Universidade de Trás-os-Montes e Alto Douro
Patricia Bermudez
Assistant Professor with Tenure
University of Lisbon
Make your next move.
Prepare your application
Review drafts before you send them.