Marco Stefano Demarchi
Research Interests
Explore related searches
Contact this professor
Get a free first email built on one of their papers, ready for you to edit and send yourself.
Articles (10)
Background Continuous intraoperative neuromonitoring has successfully demonstrated to predict impending damage to the recurrent laryngeal nerve, by detecting changes in electromyographic recordings. Despite the apparent benefits associated with continuous intraoperative neuromonitoring, its safety is still a debate. The aim of this study was to investigate the electrophysiological impact of continuous intraoperative neuromonitoring on the vagus nerve. Methods In this prospective study, the amplitude of the electromyographic wave of the vagus nerve–recurrent laryngeal nerve axis was measured both proximally and distally to the stimulation electrode placed upon the vagus nerve. Electromyographic signal amplitudes were collected at three distinct events during the operation: during the dissection of the vagus nerve, before application of the continuous stimulation electrode onto the vagus nerve and after its removal. Results In total, 169 vagus nerves were analysed, among 108 included patients undergoing continuous intraoperative neuromonitoring-enhanced endocrine neck surgeries. Electrode application resulted in a significant overall decrease in measured proximo-distal amplitudes of −10.94 µV (95 per cent c.i. −17.06 to −4.82 µV) (P < 0.005), corresponding to a mean(s.d.) decrease of −1.4(5.4) per cent. Before the removal of the electrode, the measured proximo-distal difference in amplitudes was −18.58 µV (95 per cent c.i. −28.31 to −8.86 µV) (P < 0.005), corresponding to a mean(s.d.) decrease of −2.50(9.59) per cent. Seven nerves suffered a loss of amplitude greater than 20 per cent of the baseline measurement. Conclusion In addition to supporting claims that continuous intraoperative neuromonitoring exposes the vagus nerve to injury, this study shows a mild electrophysiological impact of continuous intraoperative neuromonitoring electrode placement on the vagus nerve–recurrent laryngeal nerve axis. However, the small observed differences are negligible and were not associated with a clinically relevant outcome, making continuous intraoperative neuromonitoring a safe adjunct in selected thyroid surgeries.
Year:
2023
Year:
2022
Year:
2022
Year:
2022
Year:
2022
Year:
2021
Year:
2021
Year:
2021
Year:
2021
Year:
2021
Collaborators (2)
Pier Francesco ALESINA
Chief
-
Frédéric Triponez
University Hospital of Geneva
Make your next move.
Prepare your application
Review drafts before you send them.