Marek Czosnyka

University of Cambridge
Country flagUnited Kingdom

Research Interests

Explore related searches

Contact this professor

Get a free first email built on one of their papers, ready for you to edit and send yourself.

Articles (7)

Intracranial hypertension and adequacy of brain blood flow are primary concerns following traumatic brain injury. Intracranial pressure (ICP) monitoring is a critical diagnostic tool in neurocritical care. However, all ICP sensors, irrespective of design, are subject to systematic and random measurement inaccuracies that can affect patient care if overlooked or disregarded. The wide choice of sensors available to surgeons raises questions about performance and suitability for treatment. This observational study offers a critical review of the clinical and experimental assessment of ICP sensor accuracy and comments on the relationship between actual clinical performance, bench testing, and manufacturer specifications. Critically, on this basis, the study offers guidelines for the selection of ICP monitoring technologies, an important clinical decision. To complement this, a literature review on important ICP monitoring considerations was included. This study utilises illustrative clinical and laboratory material from 1200 TBI patients (collected from 1992 to 2019) to present several important points regarding the accuracy of in vivo implementation of contemporary ICP transducers. In addition, a thorough literature search was performed, with sources dating from 1960 to 2021. Sources considered to be relevant matched the keywords: “intraparenchymal ICP sensors”, “fiberoptic ICP sensors”, “piezoelectric strain gauge sensors”, “external ventricular drains”, “CSF reference pressure”, “ICP zero drift”, and “ICP measurement accuracy”. Based on single centre observations and the 76 sources reviewed in this paper, this material reports an overall anticipated measurement accuracy for intraparenchymal transducers of around ± 6.0 mm Hg with an average zero drift of <2.0 mm Hg. Precise ICP monitoring is a key tenet of neurocritical care, and accounting for zero drift is vital. Intraparenchymal piezoelectric strain gauge sensors are commonly implanted to monitor ICP. Laboratory bench testing results can differ from in vivo observations, revealing the shortcomings of current ICP sensors.

Year:

2023

Year:

2023

Cerebral autoregulation assessment requires sufficient slow arterial blood pressure (ABP) waves. However, spontaneous ABP waves may be insufficient for reliable cerebral autoregulation estimations. Therefore, we applied a ventilator “sigh-function” to generate positive end-expiratory pressure oscillations that induce slow ABP waves. This method demonstrated a reduced variability of the pressure reactivity index, commonly used as continuous cerebral autoregulation measure in a traumatic brain injury population.

Year:

2022

Year:

2021

Year:

2021

Year:

2020

Year:

2020

Collaborators (6)

Marcel J. H. Aries

-

NETHERLANDS
View details

Joost le Feber

Assistant professor

-

NETHERLANDS
View details

Karol Sawicki

Medical University of Białystok

POLAND
View details

T. Forcht Dagi

-

UNITED STATES
View details

Roel Haeren

Maastricht University Medical Centre

NETHERLANDS
View details

Magdalena Kasprowicz

Wrocław University of Scince and Technology

POLAND
View details
ApplyKite TwinLearns as you apply

Make your next move.

Prepare your application

Review drafts before you send them.