Mariano Bresciani

Istituto per il Rilevamento Elettromagnetico dell'Ambiente Consiglio Nazionale delle Ricerche
Country flagItaly

Research Interests

Explore related searches

Contact this professor

Get a free first email built on one of their papers, ready for you to edit and send yourself.

Articles (10)

Year:

2025

Year:

2025

Year:

2024

Year:

2024

Year:

2024

Year:

2023

The aim of this work is to test the state-of-the-art of water constituent retrieval algorithms for phycocyanin (PC) and chlorophyll-a (chl-a) concentrations in Brazilian reservoirs from hyperspectral PRISMA images and concurrent in situ data. One near-coincident Sentinel-3 OLCI dataset has also been considered for PC mapping as its high revisit time is a relevant element for mapping cyanobacterial blooms. The testing was first performed on remote sensing reflectance (Rrs), as derived by applying two atmospheric correction methods (6SV, ACOLITE) to Level 1 data and as provided in the corresponding Level 2 products (PRISMA L2C and OLCI L2-WFR). Since PRISMA images were affected by sun glint, the testing of three de-glint models was also performed. The applicability of Semi-Analytical (SA) and Mixture Density Network (MDN) algorithms in enabling PC and chl-a concentration retrieval was then tested over three PRISMA scenes; in the case of PC concentration estimation, a Random Forest (RF) algorithm was further applied. Regarding OLCI, the SA algorithm was tested for PC estimation; notably, only SA was calibrated with site-specific data from the reservoir. The algorithms were applied to the Rrs spectra provided by PRISMA L2C products—and those derived with ACOLITE, in the case of OLCI—as these data showed better agreement with in situ measurements. The SA model provided low median absolute error (MdAE) for PRISMA-derived (MdAE = 3.06 mg.m−3) and OLCI-derived (MdAE = 3.93 mg.m−3) PC concentrations, while it overestimated PRISMA-derived chl-a (MdAE = 42.11 mg.m−3). The RF model for PC applied to PRISMA performed slightly worse than SA (MdAE = 5.21 mg.m−3). The MDN showed a rather different performance, with higher errors for PC (MdAE = 40.94 mg.m−3) and lower error for chl-a (MdAE = 23.21 mg.m−3). The results overall suggest that the model calibrated with site-specific measurements performed better and indicates that SA could be applied to PRISMA and OLCI for remote sensing of PC in Brazilian reservoirs.

Year:

2023

Year:

2023

Year:

2023

Year:

2023

Collaborators (4)

Susanne Kratzer

Associate Professor

Stockholm University

SWEDEN
View details

Felipe Nincao Begliomini

University of Cambridge

UNITED KINGDOM
View details

Pierluigi Viaroli

University of Parma

ITALY
View details

Federica Braga

Istituto di Scienze Marine Consiglio Nazionale delle Ricerche

ITALY
View details
ApplyKite TwinLearns as you apply

Make your next move.

Prepare your application

Review drafts before you send them.