Mariarosaria Di Tommaso

Country flagItaly

Research Interests

Explore related searches

Contact this professor

Get a free first email built on one of their papers, ready for you to edit and send yourself.

Articles (14)

Year:

2025

Year:

2025

Year:

2025

Year:

2023

Year:

2023

Introduction Cervical length measurement using transvaginal sonography at 18 +0 –24 +0 weeks of gestation is used to identify women at risk of preterm delivery, who may benefit from treatment with progesterone to prevent premature birth. Few and conflicting data exist regarding the predictive value of cervical length measurement performed at later gestational ages. The primary objective of this study was to evaluate the predictive accuracy for spontaneous preterm birth of a single cervical length measurement performed between 24 and 32 weeks of gestation in asymptomatic singleton pregnancies at low risk for spontaneous preterm birth. The secondary objective was to test the predictive accuracy of different cervical length thresholds in the same population. Material and methods This was a historical cohort study conducted in a tertiary referral hospital. A total of 2728 asymptomatic women with singleton pregnancy at low risk for spontaneous preterm birth were recruited. Of these women, 1548 had cervical length measured at 24 +0 –27 +6 weeks of gestation and 2191 women at 28 +0 –32 +0 weeks. In all, 1010 women were present in both gestational age windows. Maternal demographics, medical and obstetrical history, and pregnancy outcome were reviewed. The predictive value of cervical length for spontaneous preterm birth was evaluated through logistic regression analysis. Results were adjusted for confounding factors. Results Overall, spontaneous preterm birth occurred in 53/2728 women (1.9%). In both the 24 +0 –27 +6 and 28 +0 –32 +0 weeks groups, a shorter cervical length was significantly associated with spontaneous preterm birth ( p < 0.01), but it had a low predictive value, as shown by the receiver operating characteristics curve analysis (areas under the curve 0.62, 95% CI 0.50–0.74 for the 24 +0 –27 +6 weeks group, and 0.61, 95% CI 0.52–0.70 in the 28 +0 –32 +0 weeks group). When the predictive accuracy for preterm delivery of different cervical length cut‐offs was evaluated, the sensitivity and positive predictive value were low in both gestational age windows, irrespective of the threshold used. Conclusions In asymptomatic women with singleton pregnancy at low risk for spontaneous preterm birth, the predictive value of cervical length after 24 +0 weeks of gestation is low. Therefore, cervical length screening in these women should be discouraged.

Year:

2023

Background Meconium-stained amniotic fluid (MSAF) is considered an alarming sign of possible fetal compromise and it has recently been reported that neonatal outcome correlates with the degree of meconium thickness. Methods We retrospectively studied 400 term infants allocated in clear amniotic fluid and grade 1, 2, and 3 MSAF groups on the basis of color and thickness of AF. Multivariable logistic regression analysis was performed to evaluate the potential independent effect of delivery with MSAF of different severity on the risk of a composite adverse neonatal outcome. Results We found that delivery with grade 2 (OR 16.82, 95% Cl 2.12–33.52; p = 0.008) and 3 (OR 33.79, 95% Cl 4.24–69.33; p < 0.001) MSAF is independently correlated with the risk of adverse neonatal outcome, such as the occurrence of at least one of the following: need of resuscitation in the delivery room, blood cord pH < 7.100, occurrence of meconium aspiration syndrome (MAS), persistent pulmonary hypertension (PPH), transient tachypnea of the newborn (TTN), acute respiratory distress syndrome (ARDS), hypoxic-ischemic encephalopathy (HIE), and sepsis. Conclusions There is a positive correlation between the severity of amniotic fluid meconium staining and thickness and the outcomes of term infants. Therefore, the evaluation and grading of MSAF during labor is useful in order to plan for the presence of a neonatologist at delivery for immediate and proper neonatal care.

Year:

2023

Year:

2023

Year:

2023

Year:

2023

Year:

2023

Year:

2022

Year:

2022

Year:

2022

Collaborators (12)

Simone Pratesi

-

ITALY
View details

Elena Niccolai

University of Florence

ITALY
View details

Paolo Bonanni

University of Florence

ITALY
View details

MARTA CASEROTTI

Assistant professor

University of Padua

ITALY
View details

Astrid Parenti

Assistant Professor

University of Florence

ITALY
View details

Alfredo Vannacci

Associate Professor of Pharmacology

University of Florence

ITALY
View details

Sara Boccalini

University of Florence

ITALY
View details

Andrea Galli

Full Professor Of Gastroenterology

University of Arkansas - Rome Center

ITALY
View details

Simone Baldi

University of Florence

ITALY
View details

Gianluca Bartolucci

University of Florence

ITALY
View details

Angela Bechini

University of Florence

ITALY
View details

Paolo Girardi

-

ITALY
View details
ApplyKite TwinLearns as you apply

Make your next move.

Prepare your application

Review drafts before you send them.