Marián Masár
Has grant
Professor
Research Interests
Make your next move.
Prepare your application
Review drafts before you send them.
Explore related searches
Recent Grants
Grant: Close
Development of new and original combinations of microchip electrophoresis with unconventional spectral detection techniques
Open Date: 2015-01-01
Close Date: 2017-12-31
Grant: Close
Methodological and application aspects of capillary electrophoresis in an automated separation system with enhanced separation capacity
Open Date: 2015-01-01
Close Date: 2017-12-31
Grant: Close
Interactive learning of analytical chemistry
Open Date: 2014-01-01
Close Date: 2015-12-31
Grant: Close
Multidimensional miniaturized separation methods combined with ion mobility spectrometry for environmental and biomedical analysis
Open Date: 2013-10-01
Close Date: 2017-09-30
Grant: Close
Development of novel combined methods of chemical analysis of trace ionic and ionogenic substances in complex environmental and biological samples
Open Date: 2012-07-01
Close Date: 2015-12-31
Articles (13)
Year:
2025
Year:
2025
Year:
2025
Year:
2025
An analytical test procedure for the direct determination of trace levels of perchlorate in drinking water by isotachophoresis combined with capillary zone electrophoresis was developed. A capillary electrophoresis analyzer with column coupling technology, capable of combining capillaries with different internal diameters, was employed in combination with conductivity detection. This combination of the capillary electrophoresis techniques facilitated preconcentration of the trace analytes and elimination of potentially interfering macro‐components. To eliminate the influence of weak and moderately strong acids on the migration of perchlorate, acidic leading electrolyte (pH 3.2) in the isotachophoresis step and acidic background electrolyte (pH 3.9) in the zone electrophoresis step were chosen. The addition of polyvinylpyrrolidone into the electrolytes enhanced the resolution of perchlorate from other anions, especially remaining anionic macro‐components. The developed method is characterized by good repeatability of migration time (relative standard deviation less than 0.2%) as well as peak area (relative standard deviation less than 5.9%), linearity ( R = 0.9996), recoveries (100–112%), and sample throughput (90 samples/24 h). The limit of quantitation for perchlorate in drinking water was achieved at 12.5 nmol/L (1.25 μg/L). This approach is more sensitive and more robust than transient isotachophoresis and offers advantages over some more established analytical techniques such as ion chromatography.
Year:
2022
Year:
2022
Year:
2021
Year:
2021
Year:
2021
Year:
2020
Year:
2020
Year:
2020
Year:
2020
Collaborators (2)
Josef Jampílek
Palacký University
Massoud Kaykhaii
Comenius University in Bratislava
Make your next move.
Prepare your application
Review drafts before you send them.