Max Wühr

Independent Research Group Leader

Ludwig-Maximilians-Universität München
Country flagGermany

Research Interests

ApplyKite TwinLearns as you apply

Make your next move.

Prepare your application

Review drafts before you send them.

Explore related searches

Articles (16)

Introduction: Eye movements are key biomarkers for diagnosing and monitoring neuro-otological, neuro-ophthalmological and neurodegenerative disorders. Video-oculography (VOG) systems enable detection of small, rapid eye movements and subtle oculomotor pathologies that may be missed during clinical exams. However, they rely on high-quality input, struggle with torsional movements, and are often limited by high costs in clinical and research settings. Methods: To overcome these limitations, we developed 3DeepVOG, a deep learning-based framework for three-dimensional monocular gaze tracking (horizontal, vertical, and torsional rotation) that operates robustly across varied imaging conditions, including low-light and noisy environments. The method combines automated pupil and iris segmentation with geometrically interpretable estimation using a two-sphere anatomical eyeball model with corneal refraction correction. Torsion is tracked in real time using a novel mini-patch template matching approach. The system was trained on over 24,000 annotated samples obtained across multiple devices and clinical scenarios. Application was tested against a gold-standard VOG system in healthy controls. Results: 3DeepVOG operates in real time (>300 fps) and achieves gaze errors of ∼0.1° in all three dimensions. Oculomotor measures – saccadic peak velocity, smooth pursuit gain, and optokinetic nystagmus slow-phase velocity – show good-to-excellent agreement with a clinical gold-standard system. As proof of concept, we present a case of acute unilateral vestibular failure where 3DeepVOG reliably captures 3D nystagmus. Conclusions: 3DeepVOG enables accurate, quantitative eye movement tracking across three dimensions under diverse conditions. As an open-source framework, it provides an accessible and scalable tool for advancing research and clinical assessment in neurological oculomotor disorders.

Year:

2025

Instrumented gait analysis is widely used in clinical settings for the early detection of neurological disorders, monitoring disease progression, and evaluating fall risk. However, the gold-standard marker-based 3D motion analysis is limited by high time and personnel demands. Advances in computer vision now enable markerless whole-body tracking with high accuracy. Here, we present vGait, a comprehensive 3D gait assessment method using a single RGB-D sensor and state-of-the-art pose-tracking algorithms. vGait was validated in healthy participants during frontal- and sagittal-perspective walking. Performance was comparable across perspectives, with vGait achieving high accuracy in detecting initial and final foot contacts (F1 scores > 95%) and reliably quantifying spatiotemporal gait parameters (e.g., stride time, stride length) and whole-body coordination metrics (e.g., arm swing and knee angle ROM) at different levels of granularity (mean, step-to-step variability, side asymmetry). The flexibility, accuracy, and minimal resource requirements of vGait make it a valuable tool for clinical and non-clinical applications, including outpatient clinics, medical practices, nursing homes, and community settings. By enabling efficient and scalable gait assessment, vGait has the potential to enhance diagnostic and therapeutic workflows and improve access to clinical mobility monitoring.

Year:

2025

Mobile health technologies enable continuous, quantitative assessment of mobility and gait in real-world environments, facilitating early diagnoses of gait disorders, disease progression monitoring, and prediction of adverse events like falls. Traditionally, mobile gait assessment predominantly relied on body-fixed sensors positioned at the feet or lower trunk. Here, we investigate the potential of an algorithm utilizing an ear-worn motion sensor for spatiotemporal segmentation of gait patterns. We collected 3D acceleration profiles from the ear-worn sensor during varied walking speeds in 53 healthy adults. Temporal convolutional networks were trained to detect stepping sequences and predict spatial relations between steps. The resulting algorithm, mEar, accurately detects initial and final ground contacts (F1 score of 99% and 91%, respectively). It enables the determination of temporal and spatial gait cycle characteristics (among others, stride time and stride length) with good to excellent validity at a precision sufficient to monitor clinically relevant changes in walking speed, stride-to-stride variability, and side asymmetry. This study highlights the ear as a viable site for monitoring gait and proposes its potential integration with in-ear vital-sign monitoring. Such integration offers a practical approach to comprehensive health monitoring and telemedical applications, by integrating multiple sensors in a single anatomical location.

Year:

2024

Postural instability is a common complication in advanced Parkinson’s disease (PD) associated with recurrent falls and fall-related injuries. The test of retropulsion, consisting of a rapid balance perturbation by a pull in the backward direction, is regarded as the gold standard for evaluating postural instability in PD and is a key component of the neurological examination and clinical rating in PD (e.g., MDS-UPDRS). However, significant variability in test execution and interpretation contributes to a low intra- and inter-rater test reliability. Here, we explore the potential for objective, vision-based assessment of the pull test (vPull) using 3D pose tracking applied to single-sensor RGB-Depth recordings of clinical assessments. The initial results in a cohort of healthy individuals (n = 15) demonstrate overall excellent agreement of vPull-derived metrics with the gold standard marker-based motion capture. Subsequently, in a cohort of PD patients and controls (n = 15 each), we assessed the inter-rater reliability of vPull and analyzed PD-related impairments in postural response (including pull-to-step latency, number of steps, retropulsion angle). These quantitative metrics effectively distinguish healthy performance from and within varying degrees of postural impairment in PD. vPull shows promise for straightforward clinical implementation with the potential to enhance the sensitivity and specificity of postural instability assessment and fall risk prediction in PD.

Year:

2024

Background Gait impairment is a key feature in later stages of Parkinson’s disease (PD), which often responds poorly to pharmacological therapies. Neuromodulatory treatment by low-intensity noisy galvanic vestibular stimulation (nGVS) has indicated positive effects on postural instability in PD, which may possibly be conveyed to improvement of dynamic gait dysfunction. Objective To investigate the effects of individually tuned nGVS on normal and cognitively challenged walking in PD patients with mild-to-moderate gait dysfunction. Methods Effects of nGVS of varying intensities (0–0.7 mA) on body sway were examined in 32 patients with PD (ON medication state, Hoehn and Yahr: 2.3 ± 0.5), who were standing with eyes closed on a posturographic force plate. Treatment response and optimal nGVS stimulation intensity were determined on an individual patient level. In a second step, the effects of optimal nGVS vs. sham treatment on walking with preferred speed and with a cognitive dual task were investigated by assessment of spatiotemporal gait parameters on a pressure-sensitive gait carpet. Results Evaluation of individual balance responses yielded that 59% of patients displayed a beneficial balance response to nGVS treatment with an average optimal improvement of 23%. However, optimal nGVS had no effects on gait parameters neither for the normal nor the cognitively challenged walking condition compared to sham stimulation irrespective of the nGVS responder status. Conclusions Low-intensity nGVS seems to have differential treatment effects on static postural imbalance and continuous gait dysfunction in PD, which could be explained by a selective modulation of midbrain-thalamic circuits of balance control.

Year:

2024

Background Postural imbalance and falls are an early disabling symptom in patients with progressive supranuclear palsy (PSP) of multifactorial origin that may involve abnormal vestibulospinal reflexes. Low-intensity noisy galvanic vestibular stimulation (nGVS) is a non-invasive treatment to normalize deficient vestibular function and attenuate imbalance in Parkinson’s disease. The presumed therapeutic mode of nGVS is stochastic resonance (SR), a mechanism by which weak sensory noise stimulation can enhance sensory information processing. Objective To examine potential treatment effects of nGVS on postural instability in 16 patients with PSP with a clinically probable and [ 18 F]PI-2620 tau-PET-positive PSP. Methods Effects of nGVS of varying intensity (0–0.7 mA) on body sway were examined, while patients were standing with eyes closed on a posturographic force plate. We assumed a bell-shaped response curve with maximal sway reductions at intermediate nGVS intensities to be indicative of SR. An established SR-curve model was fitted on individual patient outcomes and three experienced human raters had to judge whether responses to nGVS were consistent with the exhibition of SR. Results We found nGVS-induced reductions of body sway compatible with SR in 9 patients (56%) with optimal improvements of 31 ± 10%. In eight patients (50%), nGVS-induced sway reductions exceeded the minimal clinically important difference (improvement: 34 ± 5%), indicative of strong SR. Conclusion nGVS yielded clinically relevant reductions in body sway compatible with the exhibition of SR in vestibular sensorimotor pathways in at least half of the assessed patients. Non-invasive vestibular noise stimulation may be thus a well-tolerated treatment strategy to ameliorate postural symptoms in PSP.

Year:

2024

Human activity recognition (HAR) technology enables continuous behavior monitoring, which is particularly valuable in healthcare. This study investigates the viability of using an ear-worn motion sensor for classifying daily activities, including lying, sitting/standing, walking, ascending stairs, descending stairs, and running. Fifty healthy participants (between 20 and 47 years old) engaged in these activities while under monitoring. Various machine learning algorithms, ranging from interpretable shallow models to state-of-the-art deep learning approaches designed for HAR (i.e., DeepConvLSTM and ConvTransformer), were employed for classification. The results demonstrate the ear sensor’s efficacy, with deep learning models achieving a 98% accuracy rate of classification. The obtained classification models are agnostic regarding which ear the sensor is worn and robust against moderate variations in sensor orientation (e.g., due to differences in auricle anatomy), meaning no initial calibration of the sensor orientation is required. The study underscores the ear’s efficacy as a suitable site for monitoring human daily activity and suggests its potential for combining HAR with in-ear vital sign monitoring. This approach offers a practical method for comprehensive health monitoring by integrating sensors in a single anatomical location. This integration facilitates individualized health assessments, with potential applications in tele-monitoring, personalized health insights, and optimizing athletic training regimes.

Year:

2024

Year:

2024

Instrumented gait analysis is widely used in clinical settings for early detection of neurological disorders, monitoring disease progression, and evaluating fall risk. However, the gold-standard marker-based 3D motion analysis is limited by high time and personnel demands. Advances in computer vision now enable markerless whole-body tracking with high accuracy. Here, we present vGait, a comprehensive 3D gait assessment method using a single RGB-D sensor and state-of-the-art pose tracking algorithms. vGait was validated in healthy participants during frontal and sagittal perspective walking. Performance was comparable across perspectives, with vGait achieving high accuracy in detecting initial and final foot contacts (F1 scores > 95%) and reliably quantifying spatiotemporal gait parameters (e.g., stride time, stride length) and whole-body coordination metrics (e.g., arm swing and knee angle ROM) at different levels of granularity (mean, step-to-step variability, side asymmetry). The flexibility, accuracy, and minimal resource requirements of vGait make it a valuable tool for clinical and non-clinical applications, including outpatient clinics, medical practices, nursing homes, or community settings. By enabling efficient and scalable gait assessment, vGait has the potential to enhance diagnostic and therapeutic workflows and improve access to clinical mobility monitoring.

Year:

2024

Mobile health technologies enable continuous, quantitative assessment of mobility and gait in real-world environments, facilitating early diagnosis of gait disorders, disease progression monitoring, and prediction of adverse events like falls. Traditionally, mobile gait assessment predominantly relied on body-fixed sensors positioned at the feet or lower trunk. Here, we investigate the potential of an algorithm utilizing an ear-worn motion sensor for spatiotemporal segmentation of gait patterns. We collected 3D acceleration profiles from the ear-worn sensor during varied walking speeds in 53 healthy adults. Temporal convolutional networks were trained to detect stepping sequences and predict spatial relations between steps. The resulting algorithm, mEar, accurately detects initial and final ground contacts (F1 score of 99% and 91%, respectively). It enables determination of temporal and spatial gait cycle characteristics (among others stride time and stride length) with good to excellent validity at a precision sufficient to monitor clinically relevant changes in walking speed, stride-to-stride variability, and side asymmetry. This study highlights the ear as a viable site for monitoring gait and proposes its potential integration with in-ear vital sign monitoring. Such integration offers a practical approach to comprehensive health monitoring and telemedical applications, by integrating multiple sensors in a single anatomical location.

Year:

2024

Year:

2024

Year:

2023

Year:

2023

Year:

2023

Year:

2023

Year:

2023

Collaborators (3)

Julia Dlugaiczyk

University Hospital of Zurich

SWITZERLAND
View details

Günter Höglinger

Director

Ludwig-Maximilians-Universität München

GERMANY
View details

Klaus Jahn

Senior Researcher

Ludwig-Maximilians-Universität München

GERMANY
View details