Maximilian W. M. Wintergerst
Research Interests
Explore related searches
Contact this professor
Get a free first email built on one of their papers, ready for you to edit and send yourself.
Articles (11)
Fundus autofluorescence (FAF) is a prompt and non-invasive imaging modality helpful in detecting pathological abnormalities within the retina and the choroid. This narrative review and case series provides an overview on the current application of FAF in posterior and panuveitis. The literature was reviewed for articles on lesion characteristics on FAF of specific posterior and panuveitis entities as well as benefits and limitations of FAF for diagnosing and monitoring disease. FAF characteristics are described for non-infectious and infectious uveitis forms as well as masquerade syndromes. Dependent on the uveitis entity, FAF is of diagnostic value in detecting disease and following the clinical course. Currently available FAF modalities which differ in excitation wavelengths can provide different pathological insights depending on disease entity and activity. Further studies on the comparison of FAF modalities and their individual value for uveitis diagnosis and monitoring are warranted.
Year:
2024
Year:
2023
Optical coherence tomography (OCT) enables in vivo diagnostics of individual retinal layers in the living human eye. However, improved imaging resolution could aid diagnosis and monitoring of retinal diseases and identify potential new imaging biomarkers. The investigational high-resolution OCT platform (High-Res OCT; 853 nm central wavelength, 3 µm axial-resolution) has an improved axial resolution by shifting the central wavelength and increasing the light source bandwidth compared to a conventional OCT device (880 nm central wavelength, 7 µm axial-resolution). To assess the possible benefit of a higher resolution, we compared the retest reliability of retinal layer annotation from conventional and High-Res OCT, evaluated the use of High-Res OCT in patients with age-related macular degeneration (AMD), and assessed differences of both devices on subjective image quality. Thirty eyes of 30 patients with early/intermediate AMD (iAMD; mean age 75 ± 8 years) and 30 eyes of 30 age-similar subjects without macular changes (62 ± 17 years) underwent identical OCT imaging on both devices. Inter- and intra-reader reliability were analyzed for manual retinal layer annotation using EyeLab. Central OCT B-scans were graded for image quality by two graders and a mean-opinion-score (MOS) was formed and evaluated. Inter- and intra-reader reliability were higher for High-Res OCT (greatest benefit for inter-reader reliability: ganglion cell layer; for intra-reader reliability: retinal nerve fiber layer). High-Res OCT was significantly associated with an improved MOS (MOS 9/8, Z-value = 5.4, p < 0.01) mainly due to improved subjective resolution (9/7, Z-Value 6.2, p < 0.01). The retinal pigment epithelium drusen complex showed a trend towards improved retest reliability in High-Res OCT in iAMD eyes but without statistical significance. Improved axial resolution of the High-Res OCT benefits retest reliability of retinal layer annotation and improves perceived image quality and resolution. Automated image analysis algorithms could also benefit from the increased image resolution.
Year:
2023
Year:
2022
Year:
2022
Year:
2022
Year:
2022
Year:
2022
Year:
2022
Year:
2022
Year:
2022
Collaborators (8)
Uwe Pleyer
-
Felix Hagenau
University Medical Center Hamburg-Eppendorf
Rufino Silva
Aggregate Professor of Ophthalmology
University of Coimbra
Robert P Finger
-
Tim U. Krohne
University of Cologne
Thomas Ach
University Hospital Bonn
Ingo Volkmann
-
Vera C. Keil
-
Make your next move.
Prepare your application
Review drafts before you send them.