Meet ApplyKite Twin, the application assistant that learns with you
Meet your Twin, it learns with you
Your Twin learns with you
Launch week codes:30% off annual Pro20% off monthly Pro
Ends in00h00m00s
Ends in00h00m00s
Mayank M. Kansal
Has grant
Associate Professor
Research Interests
Make your next move.
Prepare your application
Review drafts before you send them.
Explore related searches
Recent Grants
Grant: Close
Hispanic Community Health Study-Study of Latinos (HCHS-SOL) HCHS-SOL Field Centers
Open Date:
Close Date:
Grant: Close
Coronary Artery Calcium and its Association with Protective/Risk Factors and Epigenetic Patterns in Diverse US Hispanic/Latino Adults
Open Date:
Close Date:
Grant: Close
Vascular Determinants of Stage B HF among Hispanics: The role of the Heart-Vascular Interaction
Open Date:
Close Date:
Grant: Close
iCardia4HF: A multi-component mHealth app and tailored text messaging intervention to promote self-care adherence and improve outcomes in patients with chronic heart failure
Open Date:
Close Date:
Articles (9)
Year:
2026
Year:
2025
Year:
2025
Year:
2025
Year:
2025
Year:
2025
Year:
2025
Year:
2025
Introduction. Coronary arteries are exposed to a variety of complex biomechanical forces during a normal cardiac cycle. These forces have the potential to contribute to coronary stent failure. Recent advances in stent design allow for the transmission of native pulsatile biomechanical forces in the stented vessel. However, there is a significant lack of evidence in a human model to measure vessel motion in native coronary arteries and stent conformability. Thus, we aimed to characterize and define coronary artery radial deformation and the effect of stent implantation on arterial deformation. Materials and Methods. Intravascular ultrasound (IVUS) pullback DICOM images were obtained from human coronary arteries using a coronary ultrasound catheter. Using two-dimensional speckle tracking, coronary artery radial deformation was defined as the inward and outward displacement (mm) and velocity (cm/s) of the arterial wall during the cardiac cycle. These deformation values were obtained in native and third-generation drug-eluting stented artery segments. Results. A total of 20 coronary artery segments were independently analyzed pre and poststent implantation for a total of 40 IVUS runs. Stent implantation impacted the degree of radial deformation and velocity. Mean radial deformation in native coronary arteries was 0.1230 mm ± 0.0522 mm compared to 0.0775 mm ± 0.0376 mm in stented vessels ( p = 0.0031 ). Mean radial velocity in native coronary arteries was 0.1194 cm/s ± 0.0535 cm/s compared to 0.0840 cm/s ± 0.0399 cm/s in stented vessels ( p = 0.0228 ). Conclusion. In this in vivo analysis of third-generation stents, stent implantation attenuates normal human coronary deformation during the cardiac cycle. The implications of these findings on stent failure and improved clinical outcomes require further investigation.
Year:
2022
Collaborators (11)
Ben Gerber
Professor and Director, Health Informatics and Implementation Science
University of Massachusetts Chan Medical School
Giselle Sosa
Research Assistant Professor
University of New Mexico
Elsayed Soliman
Director/Professor
Wake Forest School of Medicine
Priscilla Duran Luciano
Albert Einstein College of Medicine
Jiehuan Sun
Associate Professor
University of Illinois Chicago (UIC)
Josef Coresh
Professor
Johns Hopkins University
Spyros Kitsiou
Associate Professor
University of Illinois Chicago (UIC)
Susan Buchholz
Associate Dean for Research
Michigan State University
Rajat Deo
Associate Professor of Medicine
University of Pennsylvania
Morgan Grams
New York University
Larisa Tereshchenko
Staff, Associate Professor of Medicine, Cleveland Clinic Lerner College of Medicine of Case Western Reserve University
Cleveland Clinic
Make your next move.
Prepare your application
Review drafts before you send them.