Meredith Owen

Has grant

Research Assistant Professor

University of Kentucky
Country flagUnited States

Research Interests

ApplyKite TwinLearns as you apply

Make your next move.

Prepare your application

Review drafts before you send them.

Explore related searches

About

Meredith Owen is a Research Assistant Professor at the University of Kentucky, USA. Her research focuses on biomechanics and prosthetics, particularly in the design of metamaterials for pressure distribution in transtibial prosthetic sockets, as well as the effects of ACL injuries on muscle quality. She has published extensively on topics such as the accuracy of insole-measured forces during running and the strength of 3D-printed prosthetic components.

Recent Grants

Grant: Close

Establishing the Relationship Between Muscle Quality and Joint Loading for Individuals with Transtibial Amputation

Open Date: 2023-04-24

Close Date: 2024-08-31

Articles (15)

Year:

2026

Year:

2026

Uneven pressure distribution within a transtibial prosthetic socket can lead to discomfort, skin degradation, and suspended prosthesis use. Current custom interfaces to improve pressure distribution are often costly, time-intensive to fabricate, or cannot be incorporated into standard socket fabrication methods. In this technical note, we describe the design and preliminary clinical evaluation of a novel transtibial prosthetic socket insert with modifiable mechanical properties, which can be incorporated into the current clinical cycle of care. The custom insert (termed “inlay”) relies on a triangular unit cell, which can be modified based on the desired stiffness profile. Inserts are 3D printed in a soft polymer material and inset into shape-matched voids in a socket creating regions of custom offloading. Preliminary clinical efficacy of the inserts was assessed in a pilot long-term cross-over evaluation. After Institutional Review Board approval, 3 pilot participants wore a shape-matched replica of their habitual socket modified for insert use and a shape-matched socket without. Sockets were worn for 4-week each, and inner socket pressures were measured with thin film pressure sensors at the end of the wear period. Peak pressures within the distal tibial region of interest were decreased for 2 of 3 participants during midstance of level-ground walking when wearing the socket with inlays. The technical methods and results presented provide a new method to address high pressure regions within a transtibial prosthetic socket. The 3D-printed inlays can be rapidly produced allowing for easy modification and replacement without require new socket fabrication.

Year:

2025

Background: Female athletes lag behind their male counterparts in recovery from anterior cruciate ligament (ACL) injury. Quadriceps muscle size and strength are crucial factors for regaining function after ACL injury, but little is known about how these metrics vary due to biological sex. Hypothesis: Female patients have reduced vastus lateralis fiber cross-sectional area (CSA) and lower quadriceps strength after ACL injury than male patients. Study Design: Cross-sectional study. Level of Evidence: Level 4. Methods: A total of 60 participants with recent ACL tear were evaluated for vastus lateralis muscle fiber CSA, isometric quadriceps peak torque, and quadriceps rate of torque development. Linear mixed models were fit to determine differences across sex and limb for each variable of interest. Results: The female group averaged almost 20% atrophy between limbs ( P < 0.01), while the male group averaged just under 4% ( P = 0.05). Strength deficits between limbs were comparable between female and male groups. Conclusion: Immediately after ACL injury, female patients have greater between-limb differences in muscle fiber CSA but between-limb strength deficits comparable with those of male patients. Clinical Relevance: These results indicate that the underpinnings of strength loss differ based on biological sex, and thus individual patients could benefit from a sex-specific treatment approach to ACL injury.

Year:

2025

Year:

2025

Year:

2025

Center of pressure is a valuable biomechanical variable, predicting joint loading contributions during movement and giving insight into compensatory patterns. The purpose of this study was to assess the validity and reliability of force insoles in calculating vertical ground reaction force and center of pressure during return-to-sport jump testing. Ten healthy individuals performed double- and single-leg vertical and horizontal jumps on an instrumented treadmill while wearing instrumented force insoles. Vertical ground reaction force and anterior–posterior and medial–lateral center of pressure were collected at peak vertical ground reaction force from both devices. Repeat testing occurred 7 ± 5 days following the initial session. Force insoles were valid for measuring vertical ground reaction force (mean absolute error (MAE): 4.34 N/kg) and anterior–posterior center of pressure (MAE: 10% foot length) but were not valid for medial–lateral center of pressure (MAE: 50% foot width). During double-leg vertical, single-leg vertical, double-leg horizontal, and single-leg horizontal jumps, force insoles demonstrated good reliability for measurements of vertical ground reaction force (ICC: 0.89, 0.75, 0.89, and 0.91), anterior–posterior center of pressure (ICC: 0.88, 0.89, 0.94, and 0.97), and medial–lateral center of pressure (ICC: 0.72, 0.09, 0.82, and 0.73). Force insoles are a valid and reliable alternative to evaluating vertical ground reaction force and anterior–posterior center of pressure during return-to-sport jump testing.

Year:

2025

Objective Musculoskeletal injuries pose a health threat to U.S. Service members. In particular, the physical demands of walking and running with load carriage contribute to a high incidence of musculoskeletal injuries of the lower back. Active ankle exoskeleton devices are promising technologies that may help mitigate the impact of load carriage on the incidence of these injuries. However, the safe extended use of these devices requires an understanding of their beneficial or detrimental effects on the lumbar spine. In this pilot study, we investigated the impact of walking with an ankle exoskeleton device on lumbar biomechanical responses. Methods We collected motion-capture data and computed tomography images for five young, healthy men walking with a 22.7 kg (50-lb) load for 5 km at a speed of 1.3 m/s, with and without an active ankle exoskeleton (ExoBoot EB60). We developed individualized musculoskeletal and finite-element models to characterize the effects of walking distance and ExoBoot use on the trunk flexion angle, joint reaction force at the L4-L5 joint, and stress on the L4-L5 intervertebral disc annulus. Results While not statistically significant, we found that the peak trunk flexion angle and the peak annulus stress increased by 16% and 12%, respectively, after walking 5 km with the ExoBoot, and by 34% and 25%, respectively, without it. Similarly, the peak L4-L5 joint reaction force minimally increased by 4% with the ExoBoot, while it increased by 22% without the device. Conclusion ExoBoot use likely attenuates the effect of fatigue on the lumbar spine induced by walking with load carriage.

Year:

2025

Active lower-body exoskeleton devices can decrease the energy requirement of the human body by providing mechanical assistance to lower-body muscles. However, they also alter gait kinematics and kinetics, and it is not well understood whether such alterations are detrimental or beneficial to the human body. In this pilot study, we investigated the impact of walking with an ankle exoskeleton device on the biomechanics of men while carrying a heavy load. We collected computed tomography images and motion-capture data for five young, healthy men who walked 5 km (∼60 min) with a 22.7-kg load, with and without an active ankle exoskeleton (the ExoBoot EB60). We developed personalized musculoskeletal models and calculated the joint kinematics and kinetics for each participant under each walking condition. Without the ExoBoot, at 5 km compared to 0 km, on average, the peak trunk flexion angle increased by ∼35% and the stride length increased by ∼3.5%. In contrast, with the ExoBoot, the magnitude of the corresponding increases was smaller (∼16% and ∼2%, respectively). After the 5-km walk, compared to walking without the ExoBoot, its use considerably altered hip-related biomechanical parameters, e.g., it increased hip abduction angle by ∼17%, increased hip flexion moment by ∼3.5%, and decreased hip adduction moment by ∼19%. Finally, irrespective of distance, ExoBoot use significantly increased the stance duration and peak ankle plantarflexion angle ( p < 0.001). Overall, the use of the ExoBoot induced beneficial alterations in stride length and trunk-, ankle-, and hip-related parameters for men walking with load carriage. The quantitative analysis provided by this pilot study should help guide future investigations and inform the development of standards for safe and effective use of emerging exoskeleton technologies.

Year:

2025

Background Blood flow restriction training (BFRT) is a popular rehabilitation intervention after anterior cruciate ligament reconstruction (ACLR). However, there are a lack of clinical trials establishing the efficacy of using BFRT during rehabilitation to improve quadriceps muscle function. Purpose The purpose of this study is to evaluate the efficacy of blood flow restriction training to improve quadriceps muscle strength, morphology, and physiology, and knee biomechanics in individuals after ACLR in a double-blind, randomized, placebo-controlled clinical trial (NCT03364647). Methods Forty-eight athletes (20 females/28 males) were randomly assigned to low-load strength training with active BFRT or standard of care strength training with a sham unit. Treatment occurred for 1-month pre-surgery and 4 to 5 months post-surgery with both groups following the same standard rehabilitation protocol. Outcome variables were measured at baseline and 4 to 5 months post-surgery. Quadriceps muscle strength (isometric and isokinetic peak torque and rate of torque development) was measured on an isokinetic dynamometer. Quadriceps muscle morphology (physiological cross-sectional area, fibrosis) was determined using magnetic resonance imaging. Quadriceps muscle physiology (fiber type, fiber cross-sectional area, satellite cell abundance, collagen content, fibrogenic/adipogenic progenitor cells) was evaluated with muscle biopsies of the vastus lateralis. Knee extensor moment and knee flexion angle were measured via three-dimensional gait analysis. Change scores were calculated as: post-intervention – baseline. Two-sample t -tests were then used to assess between-group differences for each outcome variable. Results No significant between-group differences were found for any outcome variable. Conclusions The addition of BFRT to a rehabilitation program for athletes pre- and post-ACLR was no more effective than standard rehabilitation for improving quadriceps muscle function. Clinicians should consider the value of BFRT relative to the cost, time, and discomfort for patients in light of these results.

Year:

2024

Year:

2022

Year:

2022

Year:

2021

Year:

2020

Year:

2020

Collaborators (6)

Benjamin Brightwell

Assistant Professor of Instruction

University of Texas Medical Branch

UNITED STATES
View details

Kathryn Lucas

Assistant Professor

Creighton University

UNITED STATES
View details

Brian Noehren

University of Kentucky

UNITED STATES
View details

Christine Latham

Assistant Professor- Research Title Series

University of Kentucky

UNITED STATES
View details

Michael Samaan

Associate Professor

University of Kentucky

UNITED STATES
View details

Bruce Damon

-

UNITED STATES
View details