Natalia Kabaliuk
Senior Lecturer
Research Interests
Explore related searches
Contact this professor
Get a free first email built on one of their papers, ready for you to edit and send yourself.
About
Natalia Kabaliuk is a Senior Lecturer at the University of Canterbury, New Zealand. Her research focuses on the mechanical properties of materials, particularly in the context of sports safety and biomechanics. Recent publications include studies on the mechanical behavior of various tissues and materials, as well as innovative approaches to assessing head impacts in rugby. She is actively involved in exploring the intersection of machine learning and experimental methods to enhance safety in contact sports.
Articles (11)
Year:
2025
Year:
2025
Year:
2025
Year:
2024
Year:
2024
Year:
2024
Purpose: The kissing stent (KS) method is low-risk compared with open surgery techniques. It is often used to treat aorto-iliac occlusive disease (AIOD). Deployment of the KS geometry has a high technical success rate. However, stent patency reduces in the first 5 years potentially due to deleterious flow behavior. Potentially harmful hemodynamics due to the KS were investigated in vitro. Methodology: A compliant phantom of the aorto-iliac bifurcation was manufactured. Two surrogate stent-grafts were deployed into the phantom in the KS configuration to investigate effects of the presence of the stents, including the compliance mismatch they cause, on the hemodynamics proximal and distal to the KS. The investigation used pulsatile flow through a flow circuit to simulate abdominal aortic flow. Particle image velocimetry (PIV) was used to quantify the hemodynamics. Results: PIV identified peak proximal and distal velocity in vitro was 0.71 and 1.40m·s −1 , respectively, which were within physiological ranges. Throughout systole, flow appeared normal and undisturbed. A lumen wall collapse in the sagittal plane formed during late systole and continued to early diastole proximal to the aorto-iliac bifurcation, distal to the inlet stent position. The wall collapse led to disturbed flow proximal to the stented region in early diastole producing potential recirculation zones and abnormal flow patterns. Conclusion: The normal systolic flow behavior indicates the KS configuration is unlikely to cause an inflammatory response of the arterial walls. The collapse has not been previously identified and may potentially cause long-term patency reduction. It requires further investigation. Clinical Impact The role of this article is to provide further insight into the haemodynamic behavior through a stented aorto-iliac artery. The results of this investigation will improve the understanding of the effects that using the kissing stent method may have on a patient and help to identify high risk regions that may require more detailed monitoring. This paper also develops the in vitro modelling techniques that will enable further research that cannot be carried out within patients.
Year:
2022
Year:
2022
Year:
2022
Year:
2021
Year:
2021
Collaborators (7)
Paul Docherty
Professor
University of Canterbury
Annette G Swale
Teaching Assistant
University of Canterbury
Michael Hamlin
Professor
Lincoln University
Nick Draper
-
George Stilwell
University of Canterbury
Stephen Daynes
University of Canterbury
Benjamin Murton
University of Canterbury
Make your next move.
Prepare your application
Review drafts before you send them.