Peer W. Kämmerer
Research Interests
Explore related searches
Contact this professor
Get a free first email built on one of their papers, ready for you to edit and send yourself.
Articles (10)
Year:
2023
Year:
2023
Purpose: The present systematic review aimed to investigate the accuracy of zygomatic implant (ZI) placement using dynamic computer-aided surgery (d-CAIS), static computer-aided surgery (s-CAIS), and a free-hand approach in patients with severe atrophic edentulous maxilla and/or deficient maxilla. Methods: Electronic and manual literature searches until May 2023 were performed in the PubMed/Medline, Scopus, Cochrane Library, and Web of Science databases. Clinical trials and cadaver studies were selected. The primary outcome was planned/placed deviation. Secondary outcomes were to evaluate the survival of ZI and surgical complications. Random-effects meta-analyses were conducted and meta-regression was utilized to compare fiducial registration amounts for d-CAIS and the different designs of s-CAIS. Results: A total of 14 studies with 511 ZIs were included (Nobel Biocare: 274, Southern Implant: 42, SIN Implant: 16, non-mentioned: 179). The pooled mean ZI deviations from the d-CAIS group were 1.81 mm (95% CI: 1.34–2.29) at the entry point and 2.95 mm (95% CI: 1.66–4.24) at the apex point, and angular deviations were 3.49 degrees (95% CI: 2.04–4.93). The pooled mean ZI deviations from the s-CAIS group were 1.19 mm (95% CI: 0.83–1.54) at the entry point and 1.80 mm (95% CI: 1.10–2.50) at the apex point, and angular deviations were 2.15 degrees (95% CI: 1.43–2.88). The pooled mean ZI deviations from the free-hand group were 2.04 mm (95% CI: 1.69–2.39) at the entry point and 3.23 mm (95% CI: 2.34–4.12) at the apex point, and angular deviations were 4.92 degrees (95% CI: 3.86–5.98). There was strong evidence of differences in the average entry, apex, and angular deviation between the navigation, surgical guide, and free-hand groups (p < 0.01). A significant inverse correlation was observed between the number of fiducial screws and the planned/placed deviation regarding entry, apex, and angular measurements. Conclusion: Using d-CAIS and modified s-CAIS for ZI surgery has shown clinically acceptable outcomes regarding average entry, apex, and angular deviations. The maximal deviation values were predominantly observed in the conventional s-CAIS. Surgeons should be mindful of potential deviations and complications regardless of the decision making in different guide approaches.
Year:
2023
Year:
2023
Year:
2023
Year:
2023
Year:
2023
Year:
2023
Year:
2023
Year:
2023
Collaborators (12)
Ali Modabber
University Hospital RWTH Aachen
Juergen Kolb
-
Daniel G. E. Thiem
-
Nadine Wiesmann
Johannes Gutenberg Universität Mainz
Ulrike Ritz
-
Shahram Ghanaati
Goethe University Frankfurt
Andreas Baranowski
University Medical Center
Michael Dau
-
Rainer Lutz
University Hospital Erlangen
Pol Rommens
University Medical Center of the Johannes Gutenberg University Mainz
Till Opatz
Johannes Gutenberg Universität Mainz
Towia Libermann
Associate Professor of Medicine/Director of Beth Israel Deaconess Medical Center Genomics, Proteomics, Bioinformatics, and Systems Biology Center
Beth Israel Deaconess Medical Center
Make your next move.
Prepare your application
Review drafts before you send them.