Launch week offerEnds in00h00m00s

Razan Salem

University Hospital Frankfurt
Country flagGermany

Research Interests

ApplyKite TwinLearns as you apply

Make your next move.

Prepare your application

Review drafts before you send them.

Explore related searches

Articles (14)

Year:

2026

Year:

2026

Year:

2026

Year:

2026

Year:

2025

Year:

2025

Year:

2025

Year:

2025

Background: Minimally invasive aortic valve replacement (AVR) via upper ministernotomy (MiniAVR) is a standard alternative to full sternotomy access. Minimally invasive cardiac surgery has been proven to provide a number of benefits to patients. The aim of this study was to compare the short- and long-term outcomes after MiniAVR versus conventional AVR via full sternotomy (FS) using a biological prosthesis in an elderly higher-risk population. Methods: Between January 2006 and July 2009, 918 consecutive patients received AVR ± additional procedures with different prostheses at our center. Amongst them, 441 received isolated AVR using a biological prosthesis (median age of 74.5; range: 52–93 years; 50% females) and formed the study population (EuroSCORE II: 3.62 ± 5.5, range: 0.7–42). In total, 137 (31.1%) of the operations were carried out through FS, and 304 (68.9%) were carried out via MiniAVR. Follow-up was complete in 96% of the cases (median of 7.6 years, 6610 patient-years). Propensity score matching (PSM) resulted in two groups of 68 patients with very similar baseline profiles. The primary endpoints were long-term survival, freedom from reoperation, and endocarditis, and the secondary endpoints were early major adverse cardiac and cerebrovascular events (MACCEs). Results: FS led to shorter cardio-pulmonary bypass and aortic cross-clamp durations: 90 (47–194) vs. 100 (46–246) min (p = 0.039) and 57 (33–156) vs. 69 (32–118) min (p = 0.006), respectively. Perioperative stroke occurred in three patients (4.4%; FS) vs. one patient (1.5%; MiniAVR) (p = 0.506). The 30-day mortality was similar in both groups (2.9%, p = 1.000). Survival at 1, 5, and 10 years was 94.1 ± 3% (FS and MiniAVR), 80.3 ± 5% vs. 75.7 ± 5%, and 45.3 ± 6% vs. 43.8 ± 6%, respectively (p = 0.767). There were two (2.9%) reoperations in each group and two thrombo-embolic events (2.9%) vs. one (1.5%) thrombo-embolic event in the MiniAVR and FS groups, respectively (p = 0.596). Conclusions: In comparison to FS, MiniAVR provided similar short- and long-term outcomes in a higher-risk elderly population receiving biological prostheses. In particular, long-term survival, freedom from reoperation, and the incidence of endocarditis were comparable. These results clearly advocate for the routine use of MiniAVR as a standard procedure for AVR, even in a high-risk population.

Year:

2024

Year:

2024

Year:

2024

Year:

2024

Year:

2022

Year:

2022

Collaborators (3)

Tomas Holubec

-

GERMANY
View details

Diyar Saeed

-

GERMANY
View details

Eva Herrmann

Goethe University Frankfurt

GERMANY
View details