Meet ApplyKite Twin, the application assistant that learns with you
Meet your Twin, it learns with you
Your Twin learns with you
Launch week codes:30% off annual Pro20% off monthly Pro
Ends in00h00m00s
Ends in00h00m00s
Richard M. Caprioli
Research Interests
Explore related searches
Articles (2)
Year:
2025
Matrix‐assisted laser desorption/ionization imaging mass spectrometry (MALDI IMS) allows for highly multiplexed, untargeted detection of many hundreds of analytes from tissue. Recently, laser postionization (MALDI‐2) has been developed for increased ion yield and sensitivity for lipid IMS. However, the dependence of MALDI‐2 performance on the various lipid classes is largely unknown. To understand the effect of the applied matrix on MALDI‐2 analysis of lipids, samples including an equimolar lipid standard mixture, various tissue homogenates, and intact rat kidney tissue sections were analyzed using the following matrices: α‐cyano‐4‐hydroxycinnamic acid, 2′,5′‐dihydroxyacetophenone, 2′,5′‐dihydroxybenzoic acid (DHB), and norharmane (NOR). Lipid signal enhancement of protonated species using MALDI‐2 technology varied based on the matrix used. Although signal improvements were observed for all matrices, the most dramatic effects using MALDI‐2 were observed using NOR and DHB. For lipid standards analyzed by MALDI‐2, NOR provided the broadest coverage, enabling the detection of all 13 protonated standards, including nonpolar lipids, whereas DHB gave less coverage but gave the highest signal increase for those lipids recorded. With respect to tissue homogenates and rat kidney tissue, mass spectra were compared and showed that the number and intensity of neutral lipids tentatively identified with MALDI‐2 using NOR increased significantly (e.g., fivefold intensity increase for triacylglycerol). In the cases of DHB with MALDI‐2, the number of protonated lipids identified from tissue homogenates doubled with 152 on average compared with 76 with MALDI alone. High spatial resolution imaging (~20 μm) of rat kidney tissue showed similar results using DHB with 125 lipids tentatively identified from MALDI‐2 spectra versus just 72 using standard MALDI. From the four matrices tested, NOR provided the greatest increase in sensitivity for neutral lipids (triacylglycerol, diacylglycerol, monoacylglycerol, and cholesterol ester), and DHB provided the highest overall number of lipids detected using MALDI‐2 technology.
Year:
2020
Collaborators (4)
Agnes B. Fogo
Vanderbilt University Medical Center
Elizabeth K. Neumann
University of California
Melissa Farrow
Vanderbilt University
Angela Kruse
Vanderbilt University
Make your next move.
Prepare your application
Review drafts before you send them.